A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry

被引:56
|
作者
Salihovic, Samira [1 ]
Karrman, Anna [1 ]
Lindstrom, Gunilla [1 ]
Lind, P. Monica [2 ]
Lind, Lars [2 ]
van Bavel, Bert [1 ]
机构
[1] Univ Orebro, MTM Res Ctr, Sch Sci & Technol, SE-70182 Orebro, Sweden
[2] Uppsala Univ, Uppsala, Sweden
基金
瑞典研究理事会;
关键词
Human blood; Perfluoroalkyl substances; Structural isomers; Column-switch; PFOS; PFOA; PERFLUORINATED COMPOUNDS; HUMAN PLASMA; POLYFLUOROALKYL; EXTRACTION; EXPOSURE; TRENDS; WATER; PFOS;
D O I
10.1016/j.chroma.2013.07.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To facilitate high-throughput analysis suitable for large epidemiological studies we developed an automated column-switching ultra-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for determination of perfluorocarboxylic acids (PFCAs; C-5, C-6, C-7, C-8, C-9, C-10, C-11, C-12, and C-13), perfluoroalkyl sulfonic acids (PFSAs; C-4, C-6, C-8, and C-10), perfluorooctane sulfonamide (PFOSA), and five groups of structural perfluorooctane sulfonic acid (PFOS) isomers in human serum or plasma. The analytical procedure involves rapid protein precipitation using 96-well plates followed by an automated sample clean-up using an on-line trap column removing many potentially interfering sample components while through the mobile phase gradient the target analytes are eluted onto the analytical column for further separation and subsequent mass detection. The method was linear (R-2 <0.995) at concentrations ranging from 0.01 to 60 ng mL(-1) with method detection limits ranging between 0.01 and 0.17 ng mL(-1) depending on the analyte. The developed method was precise, with repeatability (n = 7) and reproducibility (n =103) coefficients of variation between 2% and 20% for most compounds including PFOS (2% and 8%) and its structural isomers (2-6% and 4-8%). The method was in conformity with a standard reference material. The column-switching HPLC-MS/MS method has been successfully applied for the determination of perfluoroalkyl substances including structural PFOS isomers in human plasma from an epidemiological study. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 29 条
  • [1] Determination of perfluoroalkyl acid isomers in biosolids, biosolids-amended soils and plants using ultra-high performance liquid chromatography tandem mass spectrometry
    Zhang, Hongna
    Wen, Bei
    Wen, Wen
    Ma, Yibing
    Hu, Xiaoyu
    Wu, Yali
    Luo, Lei
    Zhang, Shuzhen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1072 : 25 - 33
  • [2] Simultaneous determination of perfluoroalkyl substances and bile acids in human serum using ultra-high-performance liquid chromatography–tandem mass spectrometry
    Samira Salihović
    Alex M. Dickens
    Ida Schoultz
    Frida Fart
    Lisanna Sinisalu
    Tuomas Lindeman
    Jonas Halfvarson
    Matej Orešič
    Tuulia Hyötyläinen
    Analytical and Bioanalytical Chemistry, 2020, 412 : 2251 - 2259
  • [3] Simultaneous determination of perfluoroalkyl substances and bile acids in human serum using ultra-high-performance liquid chromatography-tandem mass spectrometry
    Salihovic, Samira
    Dickens, Alex M.
    Schoultz, Ida
    Fart, Frida
    Sinisalu, Lisanna
    Lindeman, Tuomas
    Halfvarson, Jonas
    Oresic, Matej
    Hyotylainen, Tuulia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (10) : 2251 - 2259
  • [4] A sensitive and accurate method for the determination of perfluoroalkyl and polyfluoroalkyl substances in human serum using a high performance liquid chromatography-online solid phase extraction-tandem mass spectrometry
    Yu, Chang Ho
    Patel, Bhupendra
    Palencia, Marilou
    Fan, Zhihua
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1480 : 1 - 10
  • [5] High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography–tandem mass spectrometry
    Xiao-Pen Lee
    Takeshi Kumazawa
    Chika Hasegawa
    Tetsuya Arinobu
    Hiroshi Seno
    Osamu Suzuki
    Keizo Sato
    Forensic Toxicology, 2013, 31 : 9 - 20
  • [6] A semi-automated 96-well plate method for the simultaneous determination of oral contraceptives concentrations in human plasma using ultra performance liquid chromatography coupled with tandem mass spectrometry
    Licea-Perez, Hermes
    Wang, Sherry
    Bowen, Chester L.
    Yang, Eric
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 69 - 76
  • [7] A green and rapid analytical method for determination of kitasamycin in animal feedstuffs by ultra-high performance liquid chromatography tandem mass spectrometry
    Xu, Feng
    Yu, Jiayong
    Zhang, Rongrong
    Zhang, Zeming
    Sun, Aili
    Shi, Xizhi
    Wu, Yinliang
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1676
  • [8] Simplified method for determination of clarithromycin in human plasma using protein precipitation in a 96-well format and liquid chromatography-tandem mass spectrometry
    Shin, Jaekyu
    Pauly, Daniel F.
    Johnson, Julie A.
    Frye, Reginald F.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (01): : 130 - 134
  • [9] High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry
    Lee, Xiao-Pen
    Kumazawa, Takeshi
    Hasegawa, Chika
    Arinobu, Tetsuya
    Seno, Hiroshi
    Suzuki, Osamu
    Sato, Keizo
    FORENSIC TOXICOLOGY, 2013, 31 (01) : 9 - 20
  • [10] High throughput online solid phase extraction-ultra high performance liquid chromatography-tandem mass spectrometry method for polyfluoroalkyl phosphate esters, perfluoroalkyl phosphonates, and other perfluoroalkyl substances in human serum, plasma, and whole blood
    Poothong, Somrutai
    Lundanes, Elsa
    Thomsen, Cathrine
    Haug, Line Smastuen
    ANALYTICA CHIMICA ACTA, 2017, 957 : 10 - 19