Insulin delivery systems combined with microneedle technology

被引:222
作者
Jin, Xuan [1 ]
Zhu, Dan Dan [1 ]
Chen, Bo Zhi [1 ]
Ashfaq, Mohammad [1 ]
Guo, Xin Dong [1 ]
机构
[1] Beijing Univ Chem Technol, Coll Mat Sci & Engn, Beijing Lab Biomed Mat, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Diabetes; Insulin delivery; Non-invasive; Microneedle; TRANSDERMAL DRUG-DELIVERY; BIODEGRADABLE POLYMER MICRONEEDLES; 2-LAYERED DISSOLVING MICRONEEDLES; OF-PLANE MICRONEEDLES; HOLLOW MICRONEEDLE; CONTROLLED-RELEASE; SILICON MICRONEEDLES; COATED MICRONEEDLES; SKIN PENETRATION; MICROFABRICATED MICRONEEDLES;
D O I
10.1016/j.addr.2018.03.011
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Diabetes, a metabolic disorder of glucose, is a serious chronic disease and an important public health problem. Insulin is one of the hormones for modulating blood glucose level and the products of which is indispensable for most diabetes patients. Introducing microneedles (MNs) to insulin delivery is promising to pave the way for modulating glucose level noninvasively of diabetes patients, as which born to be painless, easy to handle and no need of any power supply. In this work, we review the process of insulin delivery systems (IDSs) based on MN technology in terms of two categories: drug free MNs and drug loaded MNs. Drug free MNs include solid MNs ("poke and patch"), hollow MNs ("poke and flow") and reservoir-based swelling MNs ("poke and swell R-type"), and drug loaded MNs include coated MNs ("coat and poke"), dissolving MNs ("poke and release") and insulin incorporated swelling MNs ("poke and swell I-type"). Majority researches of MN-based IDSs have been conducted by using hollow MNs or dissolving MNs, and almost all clinical trials for MN-based IDSs have employed hollow MNs. "Poke and patch" approach dramatically increase skin permeability compared to traditional transdermal patch, but MNs fabricated from silicon or metal may leave sharp waste in the skin and cause a safety issue. "Poke and flow" approach, similar to transitional subcutaneous (SC) injection, is capable of producing faster insulin absorption and action than SC injection but may associate with blockage, leakage and low flow rate. Coated MNs are able of retaining the activity of drug, which loaded in a solid phase, for a long time, however have been relatively less studied for insulin application as the low drug dosing. "Poke and release" approach leaves no biohazardous sharp medical waste and is capable of rapid drug release. "Poke and swell R-type" can be seen as a combination of "poke and flow" and "poke and patch" approach, while "poke and swell I-type" is an approach between "coat and poke" and "poke and release" approach. Insulin MNs are promising for painless diabetes therapeutics, and additional efforts for addressing fundamental issues including the drug loading, the PK/PD profile, the storage and the safety of insulin MNs will accelerate the clinical transformation. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:119 / 137
页数:19
相关论文
共 230 条
[1]   Geometrical effects in mechanical characterizing of microneedle for biomedical applications [J].
Aggarwal, P ;
Johnston, CR .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 102 (02) :226-234
[2]   Parathyroid Hormone PTH(1-34) Formulation that Enables Uniform Coating on a Novel Transdermal Microprojection Delivery System [J].
Ameri, Mahmoud ;
Fan, Shelley C. ;
Maa, Yuh-Fun .
PHARMACEUTICAL RESEARCH, 2010, 27 (02) :303-313
[3]  
[Anonymous], 2016, ISBN, V978, P88
[4]   Micro-scale devices for transdermal drug delivery [J].
Arora, Anubhav ;
Prausnitz, Mark R. ;
Mitragotri, Samir .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2008, 364 (02) :227-236
[5]   Local transdermal delivery of phenylephrine to the anal sphincter muscle using microneedles [J].
Baek, Changyoon ;
Han, MeeRee ;
Min, Junhong ;
Prausnitz, Mark R. ;
Park, Jung-Hwan ;
Park, Jung Ho .
JOURNAL OF CONTROLLED RELEASE, 2011, 154 (02) :138-147
[6]   Why is Exubera being withdrawn? [J].
Bailey, Clifford J. ;
Barnett, Anthony H. .
BRITISH MEDICAL JOURNAL, 2007, 335 (7630) :1156-1156
[7]   In vivo assessment of safety of microneedle arrays in human skin [J].
Bal, Suzanne M. ;
Caussin, Julia ;
Pavel, Stan ;
Bouwstra, Joke A. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 35 (03) :193-202
[8]   Flux across of microneedle-treated skin is increased by increasing charge of naltrexone and naltrexol in vitro [J].
Banks, Stan L. ;
Pinninti, Raghotham R. ;
Gill, Harvinder S. ;
Crooks, Peter A. ;
Prausnitz, Mark R. ;
Stinchcomb, Audra L. .
PHARMACEUTICAL RESEARCH, 2008, 25 (07) :1677-1685
[9]  
Banting FG, 1922, CAN MED ASSOC J, V7, P141
[10]   Type 2 diabetes mellitus after gestational diabetes: a systematic review and meta-analysis [J].
Bellamy, Leanne ;
Casas, Juan-Pablo ;
Hingorani, Aroon D. ;
Williams, David .
LANCET, 2009, 373 (9677) :1773-1779