The PN-CCD detector for XMM and ABRIXAS

被引:17
作者
Meidinger, N [1 ]
Bräuninger, H [1 ]
Briel, U [1 ]
Hartmann, R [1 ]
Hartner, G [1 ]
Holl, P [1 ]
Kemmer, J [1 ]
Kendziorra, E [1 ]
Krause, N [1 ]
Lutz, G [1 ]
Pfeffermann, E [1 ]
Popp, M [1 ]
Reppin, C [1 ]
Richter, R [1 ]
Soltau, H [1 ]
Stötter, D [1 ]
Strüder, L [1 ]
Trümper, J [1 ]
von Zanthier, C [1 ]
机构
[1] MPI, Halbleiterlabor, D-81739 Garching, Germany
来源
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X | 1999年 / 3765卷
关键词
ABRIXAS; backside illumination; EPIC; JFET; pn-CCD; X-ray detector; XMM;
D O I
10.1117/12.366501
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
A 6 cm x 6 cm large monolythic charge coupled device has been developed and fabricated as focal plane X-ray detector for the European XMM satellite mission and the German ABRIXAS mission. This spectroscopic silicon detector is denominated pn-CCD because of its use of reverse biased pn-junctions as charge transfer registers, as ultra-thin homogeneous photon entrance window and far the on-chip electronics. Due to the pn-CCD concept, the whole wafer thickness of 300 mu m is sensitive to ionizing radiation. The read-out is performed in parallel and needs only 73 ms for the 36 cm(2) large detector area. A uniform low noise performance is realized by on-chip integrated JFET electronics. The two best pn-CCDs have been integrated in the flight cameras for XMM and ABRIXAS and extensively tested for the long term operation in space. The presentation comprises the basic concept of the detector, a short description of the flight device and its fabrication, tests and operation as well as the key performance parameters. The concluding outlook describes methods of further development of the pn-CCD.
引用
收藏
页码:192 / 203
页数:12
相关论文
共 42 条
[31]   A 6cmx6cm fully depleted pn-junction CCD for high resolution spectroscopy in the 0.1keV to 15keV photon energy range [J].
von Zanthier, C ;
Holl, P ;
Kemmer, J ;
Lechner, P ;
Maier, B ;
Soltau, H ;
Stotter, R ;
Brauninger, H ;
Dennerl, K ;
Haberl, F ;
Hartmann, R ;
Hartner, G ;
Hippmann, H ;
Kastelic, E ;
Kink, W ;
Krause, N ;
Meidinger, N ;
Metzner, G ;
Pfeffermann, E ;
Popp, M ;
Reppin, C ;
Stotter, D ;
Struder, L ;
Trumper, J ;
Weber, U ;
Carathanassis, D ;
Engelhard, S ;
Gebhart, T ;
Hauff, D ;
Lutz, G ;
Richter, RH ;
Seitz, H ;
Solc, P ;
Bihler, E ;
Bottcher, H ;
Kendziorra, E ;
Kramer, J ;
Pfluger, B ;
Staubert, R .
SOLID STATE SENSOR ARRAYS: DEVELOPMENT AND APPLICATIONS II, 1998, 3301 :27-36
[32]   Status of the calibration of the EPIC-pn camera onboard XMM-Newton [J].
Briel, UG ;
Dennerl, K ;
Freyberg, M ;
Haberl, F ;
Zavlin, V .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XIII, 2004, 5165 :96-103
[33]   Optical filters for the EPIC CCD-camera on board the XMM astronomy satellite [J].
Stephan, KH ;
Reppin, C ;
Haberl, F ;
Hirschinger, M ;
Maier, HJ ;
Frischke, D ;
Wedowski, M ;
Bulicke, P ;
Ulm, G ;
Friedrich, J ;
Gurtler, P .
EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 :166-173
[34]   Bright source x-ray spectroscopy with XMM-Newton: A modified EPIC-pn timing mode [J].
Kendziorra, E ;
Wilms, J ;
Haberl, F ;
Kirsch, M ;
Martin, M ;
Nowak, MA .
UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 :613-622
[35]   The EPIC-pn camera on board XMM-Newton: Performance and scientific results [J].
Briel, UG .
X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 :181-195
[36]   Effect of soft flares on XMM-Newton EPIC-pn timing mode data [J].
Burwitz, V ;
Haberl, F ;
Freyberg, M ;
Dennerl, K ;
Kendziorra, E ;
Kirsch, M .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XIII, 2004, 5165 :123-130
[37]   Taking a look at the calibration of a CCD detector with a fiber-optic taper [J].
Alkire, R. W. ;
Rotella, F. J. ;
Duke, N. E. C. ;
Otwinowski, Zbyszek ;
Borek, Dominika .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2016, 49 :415-425
[38]   A large area CCD X-ray detector for exotic atom spectroscopy [J].
Nelms, N ;
Anagnostopoulos, DF ;
Ayranov, O ;
Borchert, G ;
Egger, JP ;
Gotta, D ;
Hennebach, M ;
Indelicato, P ;
Leoni, B ;
Liu, YW ;
Manil, B ;
Simons, LM ;
Wells, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3) :419-431
[39]   Evaluation of a digital X-ray detector based on a phosphor-coated CCD for mammography [J].
Taibi, A ;
DelGuerra, A ;
Gambaccini, M ;
Marziani, M ;
Tuffanelli, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :210-213
[40]   Design and characterization of a large-area, lens-coupled CCD detector for macromolecular crystallography [J].
Westbrook, EM ;
Morse, J ;
Fisher, RE ;
McGuigan, W ;
Onishi, S ;
Vu, P ;
Naday, I ;
Bauer, C ;
Phillips, J ;
Thorson, TA ;
Durst, RD .
X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 :375-385