The PN-CCD detector for XMM and ABRIXAS

被引:17
作者
Meidinger, N [1 ]
Bräuninger, H [1 ]
Briel, U [1 ]
Hartmann, R [1 ]
Hartner, G [1 ]
Holl, P [1 ]
Kemmer, J [1 ]
Kendziorra, E [1 ]
Krause, N [1 ]
Lutz, G [1 ]
Pfeffermann, E [1 ]
Popp, M [1 ]
Reppin, C [1 ]
Richter, R [1 ]
Soltau, H [1 ]
Stötter, D [1 ]
Strüder, L [1 ]
Trümper, J [1 ]
von Zanthier, C [1 ]
机构
[1] MPI, Halbleiterlabor, D-81739 Garching, Germany
来源
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X | 1999年 / 3765卷
关键词
ABRIXAS; backside illumination; EPIC; JFET; pn-CCD; X-ray detector; XMM;
D O I
10.1117/12.366501
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
A 6 cm x 6 cm large monolythic charge coupled device has been developed and fabricated as focal plane X-ray detector for the European XMM satellite mission and the German ABRIXAS mission. This spectroscopic silicon detector is denominated pn-CCD because of its use of reverse biased pn-junctions as charge transfer registers, as ultra-thin homogeneous photon entrance window and far the on-chip electronics. Due to the pn-CCD concept, the whole wafer thickness of 300 mu m is sensitive to ionizing radiation. The read-out is performed in parallel and needs only 73 ms for the 36 cm(2) large detector area. A uniform low noise performance is realized by on-chip integrated JFET electronics. The two best pn-CCDs have been integrated in the flight cameras for XMM and ABRIXAS and extensively tested for the long term operation in space. The presentation comprises the basic concept of the detector, a short description of the flight device and its fabrication, tests and operation as well as the key performance parameters. The concluding outlook describes methods of further development of the pn-CCD.
引用
收藏
页码:192 / 203
页数:12
相关论文
共 42 条
  • [21] High speed pn-CCD's as imaging detectors from 200 nm to 1200 nm
    Strüder, L
    Hartmann, R
    Holl, P
    Kemmer, J
    Krause, N
    Lechner, P
    Lutz, G
    Meidinger, N
    Richter, RH
    Soltau, H
    Trümper, J
    von Zanthier, CV
    OPTICAL AND IR TELESCOPE INSTRUMENTATION AND DETECTORS, PTS 1 AND 2, 2000, 4008 : 368 - 374
  • [22] In-orbit performance of the EPIC-PN CCD-camera on board XMM-Newton
    Briel, UG
    Aschenbach, B
    Balasini, M
    Bräuninger, H
    Burkert, W
    Dennerl, K
    Ehle, M
    Haberl, F
    Hartmann, R
    Hartner, G
    Holl, P
    Massa, P
    Meidinger, N
    Kemmer, J
    Kendziorra, E
    Kirsch, M
    Krause, N
    Kuster, M
    Lumb, D
    Pfeffermann, E
    Pal, J
    Pietsch, W
    Popp, M
    Read, A
    Reppin, C
    Soltau, H
    Staubert, R
    Strüder, L
    Trümper, J
    Villa, G
    von Zanthier, C
    Zavlin, VE
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 154 - 164
  • [23] Performance of the XMM EPIC MOS CCD detectors
    Short, AD
    Keay, A
    Turner, MJL
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 13 - 27
  • [24] Calibration and preliminary results on the performance of the XMM EPIC PN camera:: timing modes
    Kendziorra, E
    Bihler, E
    Colli, M
    Kirsch, M
    Kuster, M
    Pflüger, B
    Staubert, R
    Bräuninger, H
    Briel, U
    Dennerl, K
    Haberl, F
    Hartner, G
    Meidinger, N
    Pfeffermann, E
    Reppin, C
    Strüder, L
    Trümper, J
    Holl, P
    Kemmer, J
    Soltau, H
    von Zanthier, C
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 50 - 59
  • [25] The spectral response of the EPIC-pn camera on board XMM-Newton
    Haberl, F
    Freyberg, M
    Briel, UG
    Dennerl, K
    Zavlin, VE
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XIII, 2004, 5165 : 104 - 111
  • [26] CCD detector development for the DUO and the ROSITA mission
    Meidinger, N
    Bonerz, S
    Englhauser, J
    Hasinger, G
    Hartmann, R
    Herrmann, S
    Holl, P
    Kettenring, G
    Kimmel, N
    Lutz, G
    Pfeffermann, E
    Predehl, P
    Soltau, H
    Strüder, L
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 66 - 77
  • [27] Calibration and preliminary results on the performance of the XMM EPIC PN flight camera:: imaging modes
    Briel, UG
    Bräuninger, H
    Dennerl, K
    Greiveldinger, C
    Haberl, F
    Hartner, G
    Meidinger, N
    Krause, N
    Popp, M
    Pfeffermann, E
    Reppin, C
    Stadelbauer, T
    Strüder, L
    Trümper, J
    Bihler, E
    Grubmiller, W
    Kendziorra, E
    Kirsch, M
    Kuster, M
    Pflüger, B
    Holl, P
    Kemmer, J
    Soltau, H
    von Zanthier, C
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 38 - 49
  • [28] Simulations and Mitigation of Pile-Up in XMM CCD Instruments
    D. H. Lumb
    Experimental Astronomy, 2000, 10 : 439 - 456
  • [29] Simulations and mitigation of pile-up in XMM CCD instruments
    Lumb, DH
    EXPERIMENTAL ASTRONOMY, 2000, 10 (04) : 439 - 455
  • [30] A 6cmx6cm fully depleted pn-junction CCD for high resolution spectroscopy in the 0.1keV to 15keV photon energy range
    von Zanthier, C
    Holl, P
    Kemmer, J
    Lechner, P
    Maier, B
    Soltau, H
    Stotter, R
    Brauninger, H
    Dennerl, K
    Haberl, F
    Hartmann, R
    Hartner, G
    Hippmann, H
    Kastelic, E
    Kink, W
    Krause, N
    Meidinger, N
    Metzner, G
    Pfeffermann, E
    Popp, M
    Reppin, C
    Stotter, D
    Struder, L
    Trumper, J
    Weber, U
    Carathanassis, D
    Engelhard, S
    Gebhart, T
    Hauff, D
    Lutz, G
    Richter, RH
    Seitz, H
    Solc, P
    Bihler, E
    Bottcher, H
    Kendziorra, E
    Kramer, J
    Pfluger, B
    Staubert, R
    SOLID STATE SENSOR ARRAYS: DEVELOPMENT AND APPLICATIONS II, 1998, 3301 : 27 - 36