DC traction power system grounding

被引:82
作者
Paul, D [1 ]
机构
[1] Earth Tech, Oakland, CA 94612 USA
关键词
equipment grounding; rail-to-ground potential; rapid transit system; stray current; system grounding; touch potential;
D O I
10.1109/TIA.2002.1003435
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper provides a review of the present practice of de traction power system grounding methods employed in North America. An analysis of equipment grounding, system grounding, and their relationships to achieve optimized equipment and personal safety is derived. Generic protective relay schemes commonly used in the dc equipment enclosure grounding are shown. Rail leakage stray current and personnel safety affected by the dc system grounding method are discussed. To enhance personnel/equipment safety, specific recommendations for the design of the dc traction power system grounding are included.
引用
收藏
页码:818 / 824
页数:7
相关论文
共 14 条
[1]  
*AIEE, 1957, IEEE REC PRACT GROUN, P784
[2]  
*ANSI IEEE, C37201 ANSI IEEE
[3]   REEVALUATION OF LETHAL ELECTRIC CURRENTS [J].
DALZIEL, CF ;
LEE, WR .
IEEE TRANSACTIONS ON INDUSTRY AND GENERAL APPLICATIONS, 1968, IGA4 (05) :467-&
[4]   Grounding of ac and dc low-voltage and medium-voltage drive systems [J].
Das, JC ;
Osman, RH .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (01) :205-216
[5]  
FORQUER P, 1993, APTA ANN C MIAM FL
[6]  
HOFFMAN DC, 1961, AIEE WINT GEN M NEW
[7]  
*IEEE, 1999, C3714 ANSI IEEE
[8]  
*IEEE, 2000, 80 ANSI IEEE
[9]  
*IEEE, 1421991 IEEE
[10]  
MOODY KJ, 1994, CORROSION 94 BALT MD