Fundamentals of calibration transfer through Procrustes analysis

被引:44
作者
Anderson, CE [1 ]
Kalivas, JH [1 ]
机构
[1] Idaho State Univ, Dept Chem, Pocatello, ID 83209 USA
关键词
calibration transfer; Procrustes analysis; direct standardization; piece-wise direct standardization; multivariate calibration;
D O I
10.1366/0003702991945515
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In analytical chemistry, it is necessary to form instrument-dependent calibration models. Problems such as instrument drift, repair, or use of a new instrument create a need for recalibration. Since recalibration can require considerable costs and cause time delays, methods for calibration transfer have been developed. This paper shows that many of these approaches are based on the statistical procedure known as Procrustes analysis (PA). Transfer by PA methods is shown to involve translation (mean-centering), rotation, and stretching of instrument responses. This study investigates the ability of different forms of PA to transfer near-infrared spectra measured on two different instruments. Spectroscopic interpretations of translation, rotation, and stretching are provided. It is found for the data sets investigated that unconstrained forms of PA generally produce better results. It is also shown that translation is the key step for transformation of spectra and may often be all that is required.
引用
收藏
页码:1268 / 1276
页数:9
相关论文
共 43 条
[1]   ACHIEVING TRANSFERABLE MULTIVARIATE SPECTRAL CALIBRATION MODELS - DEMONSTRATION WITH INFRARED-SPECTRA OF THIN-FILM DIELECTRICS ON SILICON [J].
ADHIHETTY, IS ;
MCGUIRE, JA ;
WANGMANEERAT, B ;
NIEMCZYK, TM ;
HAALAND, DM .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2329-2338
[2]   SELECTION OF ANALYTICAL VARIABLES TO OPTIMIZE LABORATORY EFFORTS IN FUTURE GROUNDWATER STUDIES [J].
ANDRADE, JM ;
PRADA, D ;
ALONSO, E ;
LOPEZ, P ;
MUNIATEGUI, S ;
DELAFUENTE, P ;
QUIJANO, MA .
ANALYTICA CHIMICA ACTA, 1994, 292 (03) :253-261
[3]   MULTIVARIATE SELECTION OF VARIABLES IN INDUSTRIAL QUALITY-CONTROL - OPTIMIZING AVIATION FUEL FINAL CONTROL [J].
ANDRADE, JM ;
PRADA, D ;
MUNIATEGUI, S ;
GOMEZ, B ;
PAN, M .
JOURNAL OF CHEMOMETRICS, 1993, 7 (05) :427-438
[4]   Applications of maximum likelihood principal component analysis: incomplete data sets and calibration transfer [J].
Andrews, DT ;
Wentzell, PD .
ANALYTICA CHIMICA ACTA, 1997, 350 (03) :341-352
[5]  
BLANCO M, 1995, APPL SPECTROSC, V49, P583
[6]   Transfer of near-infrared multivariate calibrations without standards [J].
Blank, TB ;
Sum, ST ;
Brown, SD ;
Monfre, SL .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2987-2995
[7]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[8]  
Brereton R. G., 1990, Chemometrics-applications of mathematics and statistics to laboratory systems
[9]   PROCRUSTES ROTATION AS A WAY TO COMPARE DIFFERENT SAMPLING SEASONS IN SOILS [J].
CARLOSENA, A ;
ANDRADE, JM ;
KUBISTA, M ;
PRADA, D .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2373-2378
[10]  
CLEM C, 1977, APPL SPECTROSC, V51, P744