Adaptive correction of imaging plane position in segmented K-space cine cardiac MRI

被引:18
作者
Chuang, ML [1 ]
Chen, MH [1 ]
Khasgiwala, VC [1 ]
McConnell, MV [1 ]
Edelman, RR [1 ]
Manning, WJ [1 ]
机构
[1] BETH ISRAEL HOSP,CHARLES A DANA RES INST,BOSTON,MA 02215
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 05期
关键词
heart; MR; left ventricular function; navigator echo; myocardium;
D O I
10.1002/jmri.1880070507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Variability among breath-holds frequently produces registration errors, a situation that may contribute to reproducibility error in anatomic indices, A navigator-echo-based method for real-time prospective correction of imaging slice level was applied to breath-hold cine cardiac imaging of 13 subjects. Repeat acquisitions with correction in the cardiac short-axis orientation showed significantly improved reproducibility in fractional area change and endocardial centroid location as compared with conventional noncorrected methods.
引用
收藏
页码:811 / 814
页数:4
相关论文
共 10 条
  • [1] CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE
    ATKINSON, DJ
    EDELMAN, RR
    [J]. RADIOLOGY, 1991, 178 (02) : 357 - 360
  • [2] NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE
    BUSER, PT
    AUFFERMANN, W
    HOLT, WW
    WAGNER, S
    KIRCHER, B
    WOLFE, C
    HIGGINS, CB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) : 1294 - 1300
  • [3] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263
  • [4] Coronary arteries: Three-dimensional MR imaging with retrospective respiratory gating
    Li, DB
    Kaushikkar, S
    Haacke, EM
    Woodard, PK
    Dhawale, PJ
    Kroeker, RM
    Laub, G
    Kuginuki, Y
    Gutierrez, FR
    [J]. RADIOLOGY, 1996, 201 (03) : 857 - 863
  • [5] Prospective adaptive navigator correction for breath-hold MR coronary angiography
    McConnell, MV
    Khasgiwala, VC
    Savord, BJ
    Chen, MH
    Chuang, ML
    Edelman, RR
    Manning, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 148 - 152
  • [6] REAL-TIME MOTION DETECTION IN SPIRAL MRI USING NAVIGATORS
    SACHS, TS
    MEYER, CH
    HU, BS
    KOHLI, J
    NISHIMURA, DG
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 639 - 645
  • [7] EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING
    SAKUMA, H
    FUJITA, N
    FOO, TKF
    CAPUTO, GR
    NELSON, SJ
    HARTIALA, J
    SHIMAKAWA, A
    HIGGINS, CB
    [J]. RADIOLOGY, 1993, 188 (02) : 377 - 380
  • [8] NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING
    SEMELKA, RC
    TOMEI, E
    WAGNER, S
    MAYO, J
    KONDO, C
    SUZUKI, J
    CAPUTO, GR
    HIGGINS, CB
    [J]. RADIOLOGY, 1990, 174 (03) : 763 - 768
  • [9] CORONARY MRI WITH A RESPIRATORY FEEDBACK MONITOR - THE 2D IMAGING CASE
    WANG, Y
    CHRISTY, PS
    KOROSEC, FR
    ALLEY, MT
    GRIST, TM
    POLZIN, JA
    MISTRETTA, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 116 - 121
  • [10] RESPIRATORY MOTION OF THE HEART - KINEMATICS AND THE IMPLICATIONS FOR THE SPATIAL-RESOLUTION IN CORONARY IMAGING
    WANG, Y
    RIEDERER, SJ
    EHMAN, RL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 713 - 719