Alumina-tantalum composite for femoral head applications in total hip arthroplasty

被引:4
|
作者
Huang, T. S. [1 ]
Rahaman, M. N. [1 ]
Bal, B. S. [2 ]
机构
[1] Missouri Univ Sci & Technol, Dept Mat Sci & Engn, Rolla, MO 65409 USA
[2] Univ Missouri, Dept Orthopaed Surg, Columbia, MO 65212 USA
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2009年 / 29卷 / 06期
关键词
Total hip arthroplasty; Femoral head; Composite; Alumina; Tantalum; CROSS-LINKED POLYETHYLENE; KNEE ARTHROPLASTY; FRETTING CORROSION; JOINT REPLACEMENT; BEARING SURFACES; CERAMIC BEARINGS; WEAR; REVISION;
D O I
10.1016/j.msec.2009.03.005
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Dense composite laminates of alumina (Al2O3) and tantalum (Ta) were fabricated by hot pressing and tested in vitro for potential use as a femoral head material in total hip arthroplasty (THA). Al2O3-Ta composite laminates hot pressed at 1450 degrees C and 1650 degrees C had flexural strengths of 940 +/- 180 MPa and 1090 +/- 340 MPa, respectively, which were far larger than the values of 420 +/- 140 MPa and 400 +/- 130 MPa for Al2O3 hot pressed at 1450 degrees C and 1650 degrees C, respectively. The interfacial shear strength. determined by a double-notched specimen test, was 310 +/- 80 MPa for the composite laminate hot pressed at 1650 degrees C, indicating strong interfacial bonding between Al2O3 and Ta. Scanning electron microscopy (SEM), energy dispersive X-ray (EDS) analysis, and X-ray mapping of polished sections of the hot-pressed laminates showed the presence of an interfacial region formed presumably by diffusion of 0 (at 1450 degrees C) or 0 and Al (1650 degrees C) from Al2O3 into Ta. Composite femoral heads of Al2O3 and Ta could combine the low wear of an Al2O3 articulating surface with the safety of a ductile metal femoral head. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1935 / 1941
页数:7
相关论文
共 50 条
  • [41] The association between the sagittal femoral stem alignment and the resulting femoral head centre in total hip arthroplasty
    Michael Müller
    Dirk Crucius
    Carsten Perka
    Stephan Tohtz
    International Orthopaedics, 2011, 35 : 981 - 987
  • [42] Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty
    Hummer, CD
    Rothman, RH
    Hozack, WJ
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06) : 848 - 850
  • [43] Long-term results of short stem total hip arthroplasty in patients with osteonecrosis of the femoral head
    Suksathien, Yingyong
    Suarjui, Jithayut
    Tippimanchai, Thanut
    Suksathien, Rachawan
    Lajuntuk, Bankchart
    Khamphaeng, Sirawitz
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 145 (01)
  • [44] Outcomes of Total Hip Arthroplasty in Patients with Osteonecrosis of the Femoral Head Following Surgical Treatment of Brain Tumors
    Lim, Seung-Jae
    Park, Chan-Woo
    Kim, Dong-Uk
    Han, Kwangjoon
    Seo, Minkyu
    Moon, Young-Wan
    Lee, Jung-Il
    Park, Youn-Soo
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (10)
  • [45] Severe damage of the femoral head after dislocation and difficult reduction maneuvers after total hip arthroplasty
    Schuh, A
    Mittelmeier, W
    Zeiler, G
    Behrend, D
    Kircher, J
    Bader, R
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (02) : 134 - 137
  • [46] The influence of surgical technique guidance and surgeon’s experience on the femoral head assembly in total hip arthroplasty
    Martin Darowski
    Leo Ruehrmund
    Daniel Kluess
    Annett Klinder
    Rainer Bader
    Wolfram Mittelmeier
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 2391 - 2401
  • [47] Long-term results of alumina-on-alumina total hip arthroplasty
    Rousseau, MA
    Le Mouel, S
    Goutallier, D
    Van Driessche, S
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (08): : 741 - 748
  • [48] The Effect of Bottom Profile Dimples on the Femoral Head on Wear in Metal-on-Metal Total Hip Arthroplasty
    Jamari, J.
    Ammarullah, Muhammad Imam
    Saad, Amir Putra Md
    Syahrom, Ardiyansyah
    Uddin, Mohammad
    van der Heide, Emile
    Basri, Hasan
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2021, 12 (02)
  • [49] Severe damage of the femoral head after dislocation and difficult reduction maneuvers after total hip arthroplasty
    Alexander Schuh
    Wolfram Mittelmeier
    Guenther Zeiler
    Detlef Behrend
    Joern Kircher
    Rainer Bader
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 134 - 137
  • [50] Unsuspected Malignancies in Routine Femoral Head Histopathologic Examination During Primary Total Hip Arthroplasty: Cost-Effectiveness Analysis
    Liow, Ming Han Lincoln
    Agrawal, Kshitijkumar
    Anderson, David W.
    Freiberg, Andrew A.
    Rubash, Harry E.
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03) : 735 - 742