Impact of different setup approaches in image-guided radiotherapy as primary treatment for prostate cancer

被引:0
作者
Schiller, Kilian [1 ]
Petrucci, Alessia [2 ]
Geinitz, Hans [3 ]
Schuster, Tibor [4 ]
Specht, Hanno [1 ]
Kampfer, Severin [1 ]
Duma, Marciana Nona [1 ]
机构
[1] Tech Univ Munich, Dept Radiat Oncol, Klinikum Rechts Isar, D-81675 Munich, Germany
[2] Univ Florence, Dept Radiat Oncol, Florence, Italy
[3] Krankenhaus Barmherzigen Schwestern Linz, Dept Radiat Oncol, Linz, Austria
[4] Tech Univ Munich, Klinikum Rechts Isar, Inst Med Stat & Epidemiol, D-80290 Munich, Germany
关键词
Prostate cancer; IGRT; Helical tomotherapy; Patient positioning; Radiotherapy setup errors; INTRAFRACTION MOTION; ENDORECTAL BALLOON; HELICAL TOMOTHERAPY; MARGINS; INTERFRACTION;
D O I
10.1007/s00066-014-0629-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim. The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. Methods. In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. Results. A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were >= 8 mm in 13 %, 5 %, and 44 % of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements >= 8 mm in 3 %, 19 %, and 1 % of all setups; and >= 3 mm in 27 %, 58 %, and 18 % of all fractions, respectively. For bone matching, the values were 1 %, 1 %, and 2 % and 3 %, 11 %, and 34 %, respectively. Conclusion. For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins <= 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins.
引用
收藏
页码:722 / 726
页数:5
相关论文
共 50 条
  • [31] ROLE OF INTRA- OR PERIPROSTATIC CALCIFICATIONS IN IMAGE-GUIDED RADIOTHERAPY FOR PROSTATE CANCER
    Hanna, Samir Abdallah
    Pimenta Neves-Junior, Wellington Furtado
    Marta, Gustavo Nader
    Kalil Haddad, Cecilia Maria
    Fernandes da Silva, Joao Luis
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (03): : 1208 - 1216
  • [32] Image guided radiotherapy for prostate cancer
    Soete, Guy
    Verellen, Dirk
    Storme, Guy
    [J]. BULLETIN DU CANCER, 2008, 95 (03) : 374 - 380
  • [33] Dose tracking assessment for image-guided radiotherapy of the prostate bed and the impact on clinical workflow
    Orlandini, Lucia Clara
    Coppola, Marianna
    Fulcheri, Christian
    Cernusco, Luna
    Wang, Pei
    Cionini, Luca
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [34] Dose tracking assessment for image-guided radiotherapy of the prostate bed and the impact on clinical workflow
    Lucia Clara Orlandini
    Marianna Coppola
    Christian Fulcheri
    Luna Cernusco
    Pei Wang
    Luca Cionini
    [J]. Radiation Oncology, 12
  • [35] The dosimetric impact of manual adjustments following automated registration in prostate image-guided radiotherapy
    ElBeltagi, Mohamed Nazmy
    Harper, Dean
    Coleman, Lisa
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 29 - 36
  • [36] Impact of planning target volume margins and rectal distention on biochemical failure in image-guided radiotherapy of prostate cancer
    Engels, Benedikt
    Soete, Guy
    Gevaert, Thierry
    Storme, Guy
    Michielsen, Dirk
    De Ridder, Mark
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 (01) : 106 - 109
  • [37] Inverse Relationship Between Biochemical Outcome and Acute Toxicity After Image-Guided Radiotherapy for Prostate Cancer
    Vesprini, Danny
    Catton, Charles
    Jacks, Lindsay
    Lockwood, Gina
    Rosewall, Tara
    Bayley, Andrew
    Chung, Peter
    Gospodarowicz, Mary
    Menard, Cynthia
    Milosevic, Michael
    Nichol, Alan
    Skala, Marketa
    Warde, Padraig
    Bristow, Robert G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : 608 - 616
  • [38] A comparison of three different adaptive strategies in image-guided radiotherapy of bladder cancer
    Vestergaard, Anne
    Sondergaard, Jimmi
    Petersen, Jorgen B.
    Hoyer, Morten
    Muren, Ludvig Paul
    [J]. ACTA ONCOLOGICA, 2010, 49 (07) : 1069 - 1076
  • [39] Percutaneous Image-Guided Prostate Cancer Treatment: Cryoablation as a Successful Example
    Onik, Gary
    [J]. TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 10 (02) : 149 - 158
  • [40] Image-Guided Radiotherapy A New Dimension in Radiation Oncology
    Sterzing, Florian
    Engenhart-Cabillic, Rita
    Flentje, Michael
    Debus, Juergen
    [J]. DEUTSCHES ARZTEBLATT INTERNATIONAL, 2011, 108 (16): : 274 - U17