Experimental Measurements of Constriction Resistance for Electrical Contacts Simulated Using Microfabrication

被引:4
|
作者
Fukuyama, Yasuhiro [1 ]
Sakamoto, Norihiko [1 ]
Kondo, Takaya [2 ]
Toyoizumi, Jun [2 ]
Yudate, Takahiro [2 ]
Kaneko, Nobu-Hisa [1 ]
机构
[1] AIST, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058563, Japan
[2] Yazaki Parts Co Ltd, Makinohara 4210407, Japan
基金
日本学术振兴会;
关键词
Contact resistance; electrical resistance; electrical-resistance measurement; microcontacts; microfabrication;
D O I
10.1109/TCPMT.2017.2787142
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Contact resistance in electrical connectors is a consequence of both film resistance and constriction resistance. Film resistance is caused by a material's high resistivity (e.g., oxidized metals) or contamination of the material. Constriction resistance results from the narrowing of the current as it passes through the electrical connector. In this paper, we propose a method for evaluating how contact structure affects constriction resistance using physically simulated samples processed using microfabrication. The samples' physical structure was designed and fabricated arbitrarily with an electron-beam lithography system so that the complicated contact structure could be simulated physically. Several samples representing the contact-simulated structure with various distributions of "A-spots" were fabricated, and their electrical resistances were measured precisely. The influence of electrode thickness on constriction resistance was estimated based on these precise measurements. To compare the experimental result eliminating the influences with an expression for constriction resistance, the validity of our method with physically simulated samples was confirmed. By comparing the electrical resistances of various samples with different A-spot distributions, we were able to establish a relationship between contact structure and constriction resistance.
引用
收藏
页码:927 / 931
页数:5
相关论文
共 50 条
  • [21] Experimental study of conventional wire electrical discharge machining for microfabrication
    Ali, Mohammad Yeakub
    Mohammad, Ammar Sami
    MATERIALS AND MANUFACTURING PROCESSES, 2008, 23 (07) : 641 - 645
  • [22] Correlation betweenWear Resistance and Lifetime of Electrical Contacts
    Song, Jian
    Koch, Christian
    Wang, Liangliang
    ADVANCES IN TRIBOLOGY, 2012, 2012
  • [23] Electrical Contact Resistance of Coated Spherical Contacts
    Ren, Wanbin
    Chen, Yu
    Wang, Zhaobin
    Xue, Shengjun
    Zhang, Xu
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2016, 63 (11) : 4373 - 4379
  • [24] ELECTRICAL CONTACT RESISTANCE MEASUREMENT IN ELASTOHYDRODYNAMIC CONTACTS
    Sachanas, C.
    Moisiadis, A.
    Mihailidis, A.
    JOURNAL OF THE BALKAN TRIBOLOGICAL ASSOCIATION, 2016, 22 (01): : 32 - 47
  • [25] On the electrical resistance of contacts between solid conductors
    Frenkel, J
    PHYSICAL REVIEW, 1930, 36 (11): : 1604 - 1618
  • [26] ELECTRICAL CONTACTS TO MATERIALS HAVING DISTRIBUTED RESISTANCE
    YORKE, R
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1969, 116 (05): : 897 - &
  • [27] Tribological Evaluation of Electrical Resistance of Lubricated Contacts
    Chen, Yan
    Liang, Hong
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2020, 142 (11):
  • [28] A New Model for Constriction Resistance of Rough Contacts between Nominally Flat Surfaces
    Peng, Junfeng
    Hong, Jun
    Zhuang, Yan
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 977 - 984
  • [29] The Impact on Current Density and Constriction Resistance from Bridge Structures in Real Contacts
    Malucci, Robert D.
    2017 63RD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2017, : 59 - 62
  • [30] The impact on current density and constriction resistance from bridge structures in real contacts
    Malucci, Robert D.
    Electrical Contacts, Proceedings of the Annual Holm Conference on Electrical Contacts, 2017, 0 : 59 - 62