Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry

被引:27
|
作者
Aguas, Patricia C. [1 ]
Fitzhenry, Matthew J. [1 ]
Giannikopoulos, Georgina [1 ]
Varelis, Peter [1 ]
机构
[1] Food Sci Australia, N Ryde, NSW 2113, Australia
关键词
acrylamide; tandem mass spectrometry; isotope dilution; coffee; cocoa; atmospheric pressure chemical ionisation;
D O I
10.1007/s00216-006-0560-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An accurate and precise method for the quantification of acrylamide using stable isotope dilution liquid chromatography-tandem mass spectrometry was developed and used to measure acrylamide in coffee and cocoa samples. The sample preparation involved extraction of the analyte and its internal standard, C-13(3)-acrylamide, into water and subsequent defatting of the aqueous extract with dichloromethane. An aliquot of the resulting aqueous extract was then azeotropically dried under reduced pressure and subsequently purified using an aminopropyl-bonded silica cartridge. The purified extracts were then chromatographed on a 5-mu m 2.1x150 mm Hypercarb column, the effluent of which was monitored for the analyte and its internal standard using positive-ion APCI-selected reaction monitoring. The intra-laboratory reproducibility of the method, expressed as a relative coefficient of variation (%, n=5), was determined at four levels of concentration (12.3, 42.3, 139.3 and 464.8 mu g kg(-1) and was found to vary between 0.6-2.5%. The accuracy of the method was assessed using a reference sample of coffee. The average result obtained using our method differed from the assigned value of the reference material by less than 1%. An analysis of a cocoa sample revealed that the method is capable of precisely estimating acrylamide in challenging matrices down to a level of at least 12.3 mu g kg(-1).
引用
收藏
页码:1526 / 1531
页数:6
相关论文
共 50 条
  • [41] Quantification of mycophenolic acid in plasma by isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method
    Lin, Jing
    Shen, Min
    Yu, Ting
    Wang, Huimin
    Pan, Jingjue
    Huang, Gaipeng
    Li, Quanle
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (08) : 1607 - 1617
  • [42] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Zhao, Haijian
    Zeng, Jie
    Zhang, Jiangtao
    Zhou, Weiyan
    Yan, Ying
    Wang, Yufei
    Wang, Mo
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7403 - 7411
  • [43] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Tianjiao Zhang
    Chuanbao Zhang
    Haijian Zhao
    Jie Zeng
    Jiangtao Zhang
    Weiyan Zhou
    Ying Yan
    Yufei Wang
    Mo Wang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7403 - 7411
  • [44] Measurement of Urinary Total Desmosine and Isodesmosine Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Albarbarawi, Osama
    Barton, Alun
    Lin, ZhaoSheng
    Takahashi, Eddie
    Buddharaju, Ajay
    Brady, Jeffrey
    Miller, Douglas
    Palmer, Colin N. A.
    Huang, Jeffrey T. -J.
    ANALYTICAL CHEMISTRY, 2010, 82 (09) : 3745 - 3750
  • [45] Determination of avilamycin as dichloroisoeverninic acid in poultry and porcine muscles by isotope dilution liquid chromatography-tandem mass spectrometry
    Ho, Clare
    Wong, Yiu-Tung
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (26) : 8633 - 8643
  • [46] Stable Isotope Dilution Multidimensional Liquid Chromatography-Tandem Mass Spectrometry for Pancreatic Cancer Serum Biomarker Discovery
    Yu, Kenneth H.
    Barry, Colin G.
    Austin, David
    Busch, Christine M.
    Sangar, Vineet
    Rustgi, Anil K.
    Blair, Ian A.
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (03) : 1565 - 1576
  • [47] A method for the quantitative determination of vanillylmandelic acid in urine by liquid chromatography-tandem mass spectrometry stable isotope dilution analysis.
    Magera, MJ
    Helgeson, JK
    Rinaldo, P
    CLINICAL CHEMISTRY, 2000, 46 (06) : A64 - A64
  • [48] Application of stable isotope dilution assays based on liquid chromatography-tandem mass spectrometry for the assessment of folate bioavailability
    Rychlik, M
    Netzel, M
    Pfannebecker, I
    Frank, T
    Bitsch, I
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 167 - 176
  • [49] Rapid quantitation of digoxin in human plasma and urine using isotope dilution liquid chromatography-tandem mass spectrometry
    Salvador, A
    Sagan, C
    Denouel, J
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (13) : 1917 - 1932
  • [50] Serum cholesterol measured by isotope dilution liquid chromatography tandem mass spectrometry
    Zhou, Weiyan
    Li, Hongxia
    Dong, Jun
    Wang, Shu
    Yang, Ruiyue
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (04) : 669 - 676