Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry

被引:27
|
作者
Aguas, Patricia C. [1 ]
Fitzhenry, Matthew J. [1 ]
Giannikopoulos, Georgina [1 ]
Varelis, Peter [1 ]
机构
[1] Food Sci Australia, N Ryde, NSW 2113, Australia
关键词
acrylamide; tandem mass spectrometry; isotope dilution; coffee; cocoa; atmospheric pressure chemical ionisation;
D O I
10.1007/s00216-006-0560-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An accurate and precise method for the quantification of acrylamide using stable isotope dilution liquid chromatography-tandem mass spectrometry was developed and used to measure acrylamide in coffee and cocoa samples. The sample preparation involved extraction of the analyte and its internal standard, C-13(3)-acrylamide, into water and subsequent defatting of the aqueous extract with dichloromethane. An aliquot of the resulting aqueous extract was then azeotropically dried under reduced pressure and subsequently purified using an aminopropyl-bonded silica cartridge. The purified extracts were then chromatographed on a 5-mu m 2.1x150 mm Hypercarb column, the effluent of which was monitored for the analyte and its internal standard using positive-ion APCI-selected reaction monitoring. The intra-laboratory reproducibility of the method, expressed as a relative coefficient of variation (%, n=5), was determined at four levels of concentration (12.3, 42.3, 139.3 and 464.8 mu g kg(-1) and was found to vary between 0.6-2.5%. The accuracy of the method was assessed using a reference sample of coffee. The average result obtained using our method differed from the assigned value of the reference material by less than 1%. An analysis of a cocoa sample revealed that the method is capable of precisely estimating acrylamide in challenging matrices down to a level of at least 12.3 mu g kg(-1).
引用
收藏
页码:1526 / 1531
页数:6
相关论文
共 50 条
  • [31] Sensitive isotope dilution liquid chromatography/electrospray ionization tandem mass spectrometry method for the determination of acrylamide in chocolate
    Ren, YP
    Zhang, Y
    Jiao, JJ
    Cai, ZX
    Zhang, Y
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2006, 23 (03): : 228 - 236
  • [32] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [33] Determination of phthalate esters in pastry by isotope dilution gas chromatography-tandem mass spectrometry
    Lu, Junwen
    Li, Rong
    Yang, Fang
    Huang, Zhiqiang
    Chen, Lisi
    Huang, Siyun
    Shipin Kexue/Food Science, 2016, 37 (24): : 190 - 196
  • [34] Development of a candidate reference method for determination of tyrosine in serum by isotope dilution liquid chromatography-tandem mass spectrometry
    Lee, Hwashim
    Park, Sangryoul
    Kim, Byungjoo
    Lee, Gaeho
    ANALYTICAL SCIENCES, 2007, 23 (03) : 299 - 303
  • [35] State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry
    Thienpont, Linda M.
    Van Uytfanghe, Katleen
    Blincko, Stuart
    Ramsay, Carol S.
    Xie, Hui
    Doss, Robert C.
    Keevil, Brian G.
    Owen, Laura J.
    Rockwood, Alan L.
    Kushnir, Mark M.
    Chun, Kelly Y.
    Chandler, Donald W.
    Field, Helen P.
    Sluss, Patrick M.
    CLINICAL CHEMISTRY, 2008, 54 (08) : 1290 - 1297
  • [36] Determination of 4(5)-methylimidazole in carbonated beverages by isotope-dilution liquid chromatography-tandem mass spectrometry
    Ratnayake, Geemitha
    Halldorson, Thor
    Bestvater, Lianna
    Tomy, Gregg T.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (07): : 1075 - 1082
  • [37] Determination of 17-hydroxyprogesterone in plasma by stable isotope dilution/benchtop liquid chromatography-tandem mass spectrometry
    Wudy, SA
    Hartmann, M
    Svoboda, M
    HORMONE RESEARCH, 2000, 53 (02) : 68 - 71
  • [38] Impact of sample preparation procedures of testosterone measurements by isotope-dilution liquid chromatography-tandem mass spectrometry
    Botelho, J. C.
    Shacklady, C.
    Razdan, R.
    Vesper, H. W.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A122 - A122
  • [39] Development of a Candidate Reference Method for Determination of Tyrosine in Serum by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Hwashim Lee
    Sangryoul Park
    Byungjoo Kim
    Gaeho Lee
    Analytical Sciences, 2007, 23 : 299 - 303
  • [40] Mitochondrial Coenzyme Q10 Determination by Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Itkonen, Outi
    Suomalainen, Anu
    Turpeinen, Ursula
    CLINICAL CHEMISTRY, 2013, 59 (08) : 1260 - 1267