Ultrasensitive Detection of Dual Cancer Biomarkers with Integrated CMOS-Compatible Nanowire Arrays

被引:65
作者
Lu, Na [1 ]
Gao, Anran [1 ]
Dai, Pengfei [1 ]
Mao, Hongju [2 ]
Zuo, Xiaolei [3 ]
Fan, Chunhai [3 ]
Wang, Yuelin [1 ]
Li, Tie [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Sci & Technol Microsyst Lab, Shanghai 200050, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Chinese Acad Sci, CAS Key Lab Interfacial Phys & Technol, Shanghai Inst Appl Phys, Div Phys Biol & Bioimaging Ctr,Shanghai Synchrotr, Shanghai 201800, Peoples R China
基金
中国国家自然科学基金;
关键词
PROSTATE-SPECIFIC ANTIGEN; LABEL-FREE DETECTION; SILICON-NANOWIRE; ELECTRICAL DETECTION; LUNG-CANCER; SENSOR ARRAYS; DNA; BIOSENSOR; AMPLIFICATION; TRANSISTOR;
D O I
10.1021/acs.analchem.5b01729
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct, rapid, highly sensitive and specific biosensor for detection of cancer biomarkers is desirable in early diagnosis and prognosis of cancer. However, the existing methods of detecting cancer biomarkers suffer from poor sensitivity as well as the requirement of enzymatic labeling or nanoparticle conjugations. Here, we proposed a two-channel PDMS microfluidic integrated CMOS-compatible silicon nanowire (SiNW) field-effect transistor arrays with potentially single use for label-free and ultrasensitive electrical detection of cancer biomarkers. The integrated nanowire arrays showed not only ultrahigh sensitivity of cytokeratin 19 fragment (CYFRA21-1) and prostate specific antigen (PSA) with detection to at least 1 fg/mL in buffer solution but also highly selectivity of discrimination from other similar cancer biomarkers. In addition, this method was used to detect both CYFRA21-1 and PSA real samples as low as 10 fg/mL in undiluted human serums. With its excellent properties and miniaturization, the integrated SiNW-FET device opens up great opportunities for a point-of-care test (POCT) for quick screening and early diagnosis of cancer and other complex diseases.
引用
收藏
页码:11203 / 11208
页数:6
相关论文
共 59 条
[21]   A Graphene Nanoprobe for Rapid, Sensitive, and Multicolor Fluorescent DNA Analysis [J].
He, Shijiang ;
Song, Bo ;
Li, Di ;
Zhu, Changfeng ;
Qi, Wenpeng ;
Wen, Yanqin ;
Wang, Lihua ;
Song, Shiping ;
Fang, Haiping ;
Fan, Chunhai .
ADVANCED FUNCTIONAL MATERIALS, 2010, 20 (03) :453-459
[22]   Integration of microfluidic sample delivery system on silicon nanowire-based biosensor [J].
Hemmila, Samu ;
Gao, Anran ;
Lu, Na ;
Li, Tie ;
Wang, Yuelin ;
Kallio, Pasi .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (03) :571-580
[23]   Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors [J].
Kim, Ansoon ;
Ah, Chil Seong ;
Yu, Han Young ;
Yang, Jong-Heon ;
Baek, In-Bok ;
Ahn, Chang-Guen ;
Park, Chan Woo ;
Jun, Myung Sim ;
Lee, Sungjae .
APPLIED PHYSICS LETTERS, 2007, 91 (10)
[24]   CMOS-compatible, label-free silicon-nanowire biosensors to detect cardiac troponin I for acute myocardial infarction diagnosis [J].
Kong, Tao ;
Su, Ruigong ;
Zhang, Beibei ;
Zhang, Qi ;
Cheng, Guosheng .
BIOSENSORS & BIOELECTRONICS, 2012, 34 (01) :267-272
[25]   Sensitivity Improved Surface Plasmon Resonance Biosensor for Cancer Biomarker Detection Based on Plasmonic Enhancement [J].
Law, Wing-Cheung ;
Yong, Ken-Tye ;
Baev, Alexander ;
Prasad, Pares N. .
ACS NANO, 2011, 5 (06) :4858-4864
[26]   Electrical detection of VEGFs for cancer diagnoses using anti-vascular endotherial growth factor aptamer-modified Si nanowire FETs [J].
Lee, Hyun-Seung ;
Kim, Ki Su ;
Kim, Cheol-Joo ;
Hahn, Sei Kwang ;
Jo, Moon-Ho .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1801-1805
[27]   Analysis of charge sensitivity and low frequency noise limitation in silicon nanowire sensors [J].
Lee, Jae Woo ;
Jang, Doyoung ;
Kim, Gyu Tae ;
Mouis, Mireille ;
Ghibaudo, Gerard .
JOURNAL OF APPLIED PHYSICS, 2010, 107 (04)
[28]   An Ultrasensitive Nanowire-Transistor Biosensor for Detecting Dopamine Release from Living PC12 Cells under Hypoxic Stimulation [J].
Li, Bor-Ran ;
Hsieh, Ying-Jhu ;
Chen, Yan-Xi ;
Chung, Ya-Ting ;
Pan, Chien-Yuan ;
Chen, Yit-Tsong .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (43) :16034-16037
[29]   Sequence-specific label-free DNA sensors based on silicon nanowires [J].
Li, Z ;
Chen, Y ;
Li, X ;
Kamins, TI ;
Nauka, K ;
Williams, RS .
NANO LETTERS, 2004, 4 (02) :245-247
[30]   Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor Based on Quantum Dots and a Lateral Flow Test Strip [J].
Li, Zhaohui ;
Wang, Ying ;
Wang, Jun ;
Tang, Zhiwen ;
Pounds, Joel G. ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2010, 82 (16) :7008-7014