Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors

被引:29
|
作者
Mroczek, Tomasz [1 ]
机构
[1] Med Univ Lublin, Chair & Dept Pharmacognosy, Fac Pharm, Med Plants Unit, 1 Chodzki St, PL-20093 Lublin, Poland
关键词
Two-dimensional chromatography; Thin layer chromatography/high performance liquid chromatography/mass spectrometry; Electrospray ionization; Cholinesterase inhibitors; Plant extracts; LC-MS FINGERPRINTS; TLC-MS; ACETYLCHOLINESTERASE INHIBITORS; IDENTIFICATION; ALKALOIDS;
D O I
10.1016/j.jpba.2016.06.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50 x 2.1 mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2 min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC-based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picrylhydrazyl DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 50 条
  • [21] Qualitative and quantitative analysis of chemical constituents in traditional Chinese medicinal formula Tong-Xie-Yao-Fang by high-performance liquid chromatography/diode array detection/electrospray ionization tandem mass spectrometry
    Yan, Zhixiang
    Yang, Xinghao
    Wu, Jianbo
    Su, Huai
    Chen, Chen
    Chen, Yin
    ANALYTICA CHIMICA ACTA, 2011, 691 (1-2) : 110 - 118
  • [22] Two-dimensional analysis of phenolic acids in seedling roots by high performance liquid chromatography-electrospray ionization-ion mobility spectrometry
    Lu, Yaling
    Guo, Jianpeng
    Yu, Jianna
    Guo, Jianheng
    Jia, Xu
    Liu, Wenjie
    Tian, Pingfang
    ANALYTICAL METHODS, 2019, 11 (05) : 610 - 617
  • [23] Rapid visualized characterization of phenolic taste compounds in tea extract by high-performance thin-layer chromatography coupled to desorption electrospray ionization mass spectrometry
    Tang, Chen
    Guo, Tianyang
    Zhang, Zhanxin
    Yang, Ping
    Song, Huanlu
    FOOD CHEMISTRY, 2021, 355
  • [24] High-speed separation and characterization of major constituents in Radix Paeoniae Rubra by fast high-performance liquid chromatography coupled with diode-array detection and time-of-flight mass spectrometry
    Liu, E-Hu
    Qi, Lian-Wen
    Li, Bin
    Peng, Yong-Bo
    Li, Ping
    Li, Chang-Yin
    Cao, Jun
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (01) : 119 - 130
  • [25] Integrating qualitative and quantitative characterization of traditional Chinese medicine injection by high-performance liquid chromatography with diode array detection and tandem mass spectrometry
    Xie, Yuan-yuan
    Xiao, Xue
    Luo, Juan-min
    Fu, Chan
    Wang, Qiao-wei
    Wang, Yi-ming
    Liang, Qiong-lin
    Luo, Guo-an
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (12) : 1438 - 1447
  • [26] Determination of High Boiling Point Polycyclic Aromatic Hydrocarbons by High Performance Liquid Chromatography-Ag+ Electrospray Ionization-Time of Flight-Mass Spectrometry
    Zhao Heng-Qiang
    Chen Jun-Hui
    Cheng Hong-Yan
    Zhang Dao-Lai
    Shi Qian
    Wang Xiao-Ru
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (11) : 1599 - 1603
  • [27] Nontargeted Lipidomic Characterization of Porcine Organs Using Hydrophilic Interaction Liquid Chromatography and Off-Line Two-Dimensional Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Cifkova, Eva
    Holcapek, Michal
    Lisa, Miroslav
    LIPIDS, 2013, 48 (09) : 915 - 928
  • [28] Chemical profiling and quantification of Yihuang decoction by high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry and a diode array detector
    Zhou, Jinxin
    Yu, Sheng
    Wang, Bingqian
    Wei, Xing
    Zhang, Li
    Shan, Mingqiu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 224
  • [29] Analysis of ascorbic acid based black powder substitutes by high-performance liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry
    Bottegal, Megan
    Lang, Lisa
    Miller, Mark
    McCord, Bruce
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (09) : 1377 - 1386
  • [30] Quantitative and qualitative analysis of hemicellulose, cellulose and lignin bio-oils by comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry
    Michailof, Chrysoula
    Sfetsas, Themistoklis
    Stefanidis, Stylianos
    Kalogiannis, Konstantinos
    Theodoridis, Georgios
    Lappas, Angelos
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1369 : 147 - 160