Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors

被引:29
|
作者
Mroczek, Tomasz [1 ]
机构
[1] Med Univ Lublin, Chair & Dept Pharmacognosy, Fac Pharm, Med Plants Unit, 1 Chodzki St, PL-20093 Lublin, Poland
关键词
Two-dimensional chromatography; Thin layer chromatography/high performance liquid chromatography/mass spectrometry; Electrospray ionization; Cholinesterase inhibitors; Plant extracts; LC-MS FINGERPRINTS; TLC-MS; ACETYLCHOLINESTERASE INHIBITORS; IDENTIFICATION; ALKALOIDS;
D O I
10.1016/j.jpba.2016.06.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50 x 2.1 mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2 min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC-based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picrylhydrazyl DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 50 条
  • [1] Desorption Electrospray Ionization Mass Spectrometry Analysis of Lipids after Two-Dimensional High-Performance Thin-Layer Chromatography Partial Separation
    Paglia, Giuseppe
    Ifa, Demian R.
    Wu, Chunping
    Corso, Gaetano
    Cooks, R. Graham
    ANALYTICAL CHEMISTRY, 2010, 82 (05) : 1744 - 1750
  • [2] High-performance thin-layer chromatography hyphenated to high-performance liquid chromatography-diode array detection-mass spectrometry for characterization of coeluting isomers
    Moricz, Agnes M.
    Lapat, Virag
    Morlock, Gertrud E.
    Ott, Peter G.
    TALANTA, 2020, 219
  • [3] Qualitative and quantitative analysis of pyrolysis oil by gas chromatography with flame ionization detection and comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry
    Sfetsas, Themistoklis
    Michailof, Chrysa
    Lappas, Angelos
    Li, Qiangyi
    Kneale, Brian
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3317 - 3325
  • [4] Qualitative and quantitative determination of the major coumarins in Zushima by high performance liquid chromatography with diode array detector and mass spectrometry
    Su, Juan
    Zhang, Chuan
    Zhang, Wei
    Shen, Yun-heng
    Li, Hui-liang
    Liu, Run-hui
    Zhang, Xi
    Hu, Xiao-jia
    Zhang, Wei-dong
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (11) : 2111 - 2117
  • [5] Structural Characterization and Identification of Major Constituents in Jitai Tablets by High-Performance Liquid Chromatography/Diode-Array Detection Coupled with Electrospray Ionization Tandem Mass Spectrometry
    Wang, Shuping
    Liu, Lei
    Wang, Lingling
    Hu, Yaohua
    Zhang, Weidong
    Liu, Runhui
    MOLECULES, 2012, 17 (09): : 10470 - 10493
  • [6] Qualitative and quantitative evaluation of Microctis Folium (the leaves of Microcos paniculata L.) by high performance liquid chromatography coupled with diode array detection and electrospray ionization tandem mass spectrometry
    Hu, Kua
    Zhang, Jia-yu
    Zan, Ke
    Li, Jun
    Tu, Peng-fei
    ANALYTICAL METHODS, 2014, 6 (17) : 6850 - 6859
  • [7] Qualitative and quantitative analysis of diterpenoids in Salvia species by liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry
    Zhou, Yan
    Xu, Gang
    Choi, Franky Fung Kei
    Ding, Li-Sheng
    Bin Han, Quan
    Song, Jing Zheng
    Qiao, Chun Feng
    Zhao, Qin-Shi
    Xu, Hong-Xi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (24) : 4847 - 4858
  • [8] Qualitative and quantitative analysis of the major constituents in Chinese medicinal preparation Dan-Lou tablet by ultra high performance liquid chromatography/diode-array detector/quadrupole time-of-flight tandem mass spectrometry
    Dong, Juan
    Zhu, Yan
    Gao, Xiumei
    Chang, Yanxu
    Wang, Meng
    Zhang, Peng
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 80 : 50 - 62
  • [9] Analysis of lignans in Schisandra chinensis and rat plasma by high-performance liquid chromatography diode-array detection, time-of-flight mass spectrometry and quadrupole ion trap mass spectrometry
    Lou, Ziyang
    Zhang, Hai
    Gong, Chungui
    Zhu, Zhenyu
    Zhao, Liang
    Xu, Yuanjie
    Wang, Bin
    Zhang, Guoqing
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (06) : 831 - 842
  • [10] New features on the fragmentation patterns of homoisoflavonoids in Ophiopogon japonicus by high-performance liquid chromatography/diode-array detection/electrospray ionization with multi-stage tandem mass spectrometry
    Qi, Jin
    Xu, Deran
    Zhou, Yi-Feng
    Qin, Min-Jian
    Yu, Bo-Yang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (15) : 2193 - 2206