Can We Provide Low Intrarenal Pressures with Good Irrigation Flow by Decreasing the Size of Ureteral Access Sheaths?

被引:94
作者
Sener, Tarik Emre [1 ]
Cloutier, Jonathan [1 ]
Villa, Luca [1 ]
Marson, Francesco [1 ]
Buttice, Salvatore [1 ]
Doizi, Steeve [1 ]
Traxer, Olivier [1 ]
机构
[1] Univ Paris 06, Tenon Univ Hosp, F-5020 Paris, France
关键词
PELVIC PRESSURE; URETEROPYELOSCOPY; URETERORENOSCOPY; URETEROSCOPY;
D O I
10.1089/end.2015.0387
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and Purpose: Flexible ureterorenoscopy (F-URS) plays a major role in the management of kidney stones. Ureteral access sheaths (UAS) are important tools for F-URS. In this study, we aimed to evaluate the difference in intrarenal pressures between different flexible ureteroscopes while using the same UAS and to calculate the irrigation flow variance. Materials and Methods: Eight different flexible ureteroscopes were tested with five different UAS on an artificial kidney model to measure intrarenal pressures and irrigation flow. Irrigation at 60cmH(2)O pressure was performed; the pressure and the irrigation flow amount were recorded with different states of the operator channel: Free, with the laser fiber (272m), and with the nitinol basket (1.9F) inside. Results: The highest pressure recorded was 46.68cmH(2)O with Wolf Boa and 9.5/11.5F Cook Medical UAS. All the ureteroscopes that fit inside the 10/12F Coloplast ReTrace provided pressures below 40cmH(2)O. The inner diameter of the 10/12F Rocamed Bi-Flex is actually 11F, so intrarenal pressures were lower and irrigation flow was higher. With the 11/13F Boston Scientific Navigator HD and 12/14F Coloplast ReTrace, the pressures were very low. The irrigation flow measurements were in concordance with pressure measurements. Conclusion: The ureteroscope sizes diminished with advancements in technology. Small-sized ureteroscopes can provide low intrarenal pressures with good irrigation flow when used with convenient small-sized access sheaths. The compatibility between the ureteroscopes and UASs should be anticipated by all endourologists and considered during F-URS. The advantages of 10/12UASs in terms of intrarenal pressure and irrigational flow should make these access sheaths an interesting first-line choice.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 15 条
[11]   THE URETERAL ACCESS SYSTEM - A REVIEW OF THE IMMEDIATE RESULTS IN 43 CASES [J].
NEWMAN, RC ;
HUNTER, PT ;
HAWKINS, IF ;
FINLAYSON, B .
JOURNAL OF UROLOGY, 1987, 137 (03) :380-383
[12]   Characterization of intrapelvic pressure during ureteropyeloscopy with ureteral access sheaths [J].
Rehman, J ;
Monga, M ;
Landman, J ;
Lee, DI ;
Felfela, T ;
Conradie, MC ;
Srinivas, R ;
Sundaram, CP ;
Clayman, RV .
UROLOGY, 2003, 61 (04) :713-718
[13]   MORPHOLOGICAL AND PHYSIOLOGICAL-CHANGES IN THE URINARY-TRACT ASSOCIATED WITH URETERAL DILATION AND URETEROPYELOSCOPY - AN EXPERIMENTAL-STUDY [J].
SCHWALB, DM ;
ESHGHI, M ;
DAVIDIAN, M ;
FRANCO, I .
JOURNAL OF UROLOGY, 1993, 149 (06) :1576-1585
[14]  
Traxer O, 2015, WORLD J UROL
[15]   Prospective Evaluation and Classification of Ureteral Wall Injuries Resulting from Insertion of a Ureteral Access Sheath During Retrograde Intrarenal Surgery [J].
Traxer, Olivier ;
Thomas, Alexandre .
JOURNAL OF UROLOGY, 2013, 189 (02) :580-584