Detection of trace gases by rapidly-swept continuous-wave cavity ringdown spectroscopy: pushing the limits of sensitivity

被引:41
作者
He, Y. [1 ]
Orr, B. J. [1 ]
机构
[1] Macquarie Univ, Ctr Lasers & Applicat, Sydney, NSW 2109, Australia
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2006年 / 85卷 / 2-3期
关键词
D O I
10.1007/s00340-006-2371-2
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cavity ringdown (CRD) absorption spectroscopy enables spectroscopic sensing of gases with a high sensitivity and accuracy. Instrumental improvements result in a new high-performance continuous-wave (cw) CRD spectrometer using a rapidly-swept cavity of simple design. It employs efficient data-acquisition procedures, high-reflectivity mirrors, a low-adsorption flow cell, and various compact fibre-optical components in a single-ended transmitter-receiver configuration suitable for remote sensing. Baseline noise levels in our latest cw-CRD experiments yield a competitive noise-equivalent absorption limit of similar to 5x10(-10) cm(-1) Hz(-1/2), independent of whatever molecules are to be detected. Measurements in the near-infrared wavelength range of 1.51-1.56 mu m yield sub-ppmv (i.e., ppbv or better) sensitivity in the gas phase for several representative molecules (notably CO2, CO, H2O, NH3, C2H2, and other hydrocarbons). By measuring spectroscopic features in the 1.525 mu m band of C2H2 gas, we realise detection limits of 19 nTorr (2.5x10(-11) atm) of neat C2H2 (Doppler-limited at low pressure) and 0.37 ppbv of C2H2 in air (pressure-broadened at 1 atm). Our cw-CRD spectrometer is a high-performance sensor in a relatively simple, low-cost, compact instrument that is amenable to chemical analysis of trace gases in medicine, agriculture, industry, and the environment.
引用
收藏
页码:355 / 364
页数:10
相关论文
共 71 条
[1]   Solving chemical problems of environmental importance using cavity ring-down spectroscopy [J].
Atkinson, DB .
ANALYST, 2003, 128 (02) :117-125
[2]   Broad-band cavity ring-down spectroscopy [J].
Ball, SM ;
Jones, RL .
CHEMICAL REVIEWS, 2003, 103 (12) :5239-5262
[3]   CELL COATINGS TO MINIMIZE SAMPLE (NH3 AND N2H4) ADSORPTION FOR LOW-LEVEL PHOTOACOUSTIC DETECTION [J].
BECK, SM .
APPLIED OPTICS, 1985, 24 (12) :1761-1763
[4]   Cavity ring-down spectroscopy: Experimental schemes and applications [J].
Berden, G ;
Peeters, R ;
Meijer, G .
INTERNATIONAL REVIEWS IN PHYSICAL CHEMISTRY, 2000, 19 (04) :565-607
[5]   Absorption spectroscopy in high-finesse cavities for atmospheric studies [J].
Brown, SS .
CHEMICAL REVIEWS, 2003, 103 (12) :5219-5238
[6]  
BUSCH KW, 1999, ACS S SER, V720
[7]   Application of a continuous-wave tunable erbium-doped fiber laser to molecular spectroscopy in the near infrared [J].
Cousin, J ;
Masselin, P ;
Chen, W ;
Boucher, D ;
Kassi, S ;
Romanini, D ;
Szriftgiser, P .
APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 83 (02) :261-266
[8]   Stable isotope ratios using cavity ring-down spectroscopy:: Determination of 13C/12C for carbon dioxide in human breath [J].
Crosson, ER ;
Ricci, KN ;
Richman, BA ;
Chilese, FC ;
Owano, TG ;
Provencal, RA ;
Todd, MW ;
Glasser, J ;
Kachanov, AA ;
Paldus, BA ;
Spence, TG ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2003-2007
[9]   High-speed cavity ringdown spectroscopy with increased spectral resolution by simultaneous laser and cavity tuning [J].
Debecker, I ;
Mohamed, AK ;
Romanini, D .
OPTICS EXPRESS, 2005, 13 (08) :2906-2915
[10]   Trace moisture detection using continuous-wave cavity ring-down spectroscopy [J].
Dudek, JB ;
Tarsa, PB ;
Velasquez, A ;
Wladyslawski, M ;
Rabinowitz, P ;
Lehmann, KK .
ANALYTICAL CHEMISTRY, 2003, 75 (17) :4599-4605