Organic mass spectrometry and control of fragmentation using a fast flow glow discharge ion source

被引:4
作者
Newman, Karla [1 ]
Mason, Rod S. [1 ]
机构
[1] Univ Coll Swansea, Dept Chem, Swansea SA2 8PP, W Glam, Wales
关键词
D O I
10.1002/rcm.2560
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Representative organic vapors have been introduced into the flowing afterglow of a low power (< 5W) dc-glow discharge, coupled to a quadrupole mass spectrometer. When a positive bias was applied to the ion sampling orifice, the very surprising result was that molecular mass spectra were obtained with a high sensitivity. When a negative bias was applied to the ion sampling orifice, fragmentation of the analyte was observed with an increase in the extent of ion dissociation as the voltage was increased. The breakdown pattern is compound-specific and would be useful in confirming the identity of an unknown sample. When combined with chromatographic separation, the FFGD-MS technique could be used for chemical speciation studies at the sub-picogram level. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:2067 / 2073
页数:7
相关论文
共 40 条
[1]   COMPARISONS BETWEEN A GRIMM-TYPE GLOW-DISCHARGE AND A JET-ASSISTED GLOW-DISCHARGE SOURCE VIEWED AXIALLY AND LATERALLY [J].
BANKS, PR ;
BLADES, MW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (13) :1435-1446
[2]   The use of radiofrequency glow discharge-mass spectrometry (rf-GD-MS) coupled to gas chromatography for the determination of selenoaminoacids in biological samples [J].
Bayón, MM ;
B'Hymer, C ;
de León, CAP ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :492-497
[3]   The potential of a modified rf glow discharge source for enhanced elemental speciation studies [J].
Belkin, M ;
Waggoner, JW ;
Caruso, JA .
ANALYTICAL COMMUNICATIONS, 1998, 35 (09) :281-283
[4]   Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection [J].
Belkin, MA ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1255-1261
[5]   Development and analytical characterization of a Grimm-type glow discharge ion source operated with high gas flow rates and coupled to a mass spectrometer with high mass resolution [J].
Beyer, C ;
Feldmann, I ;
Gilmour, D ;
Hoffmann, V ;
Jakubowski, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (10) :1521-1533
[6]   HIGH-PRESSURE COLLISIONAL ACTIVATION MASS-SPECTROMETRY [J].
BLOM, K ;
MUNSON, B .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1983, 105 (12) :3793-3799
[7]   Fundamental aspects and applications of glow discharge spectrometric techniques [J].
Bogaerts, A ;
Gijbels, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (01) :1-42
[8]   CHARACTERIZATION OF A GLOW-DISCHARGE ION-SOURCE FOR THE MASS-SPECTROMETRIC ANALYSIS OF ORGANIC-COMPOUNDS [J].
CARAZZATO, D ;
BERTRAND, MJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) :305-315
[9]   Enhanced formation of negative ions by electron attachment to highly excited molecules in a flowing afterglow plasma [J].
Ding, WX ;
McCorkle, DL ;
Pinnaduwage, LA .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (06) :3051-3058
[10]   SPIN-DEPENDENT STUDIES OF THE DYNAMICS OF HE(2(3)S) ATOM DEEXCITATION AT SURFACES [J].
DUNNING, FB ;
NORDLANDER, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (2-3) :245-252