Technical Note: Density correction to improve CT number mapping in thoracic deformable image registration

被引:4
作者
Yang, Jinzhong [1 ]
Zhang, Yongbin [2 ]
Zhang, Zijian [1 ,3 ]
Zhang, Lifei [1 ]
Batter, Peter [1 ]
Court, Laurence [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Cincinnati, Proton Therapy Ctr, Med Ctr, Liberty Township, OH USA
[3] Cent S Univ, Xiangya Hosp, Changsha, Hunan, Peoples R China
基金
美国国家卫生研究院;
关键词
deformable image registration; density correction; Jacobian; lung cancer; NORMAL ORGAN WEIGHTS; II-THE-BRAIN; CANCER-PATIENTS; RADIOTHERAPY; CHAIR; VALIDATION; POSITION; SPLEEN; LUNGS; LIVER;
D O I
10.1002/mp.13502
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To improve the accuracy of computed tomography (CT) number mapping inside the lung in deformable image registration with large differences in lung volume for applications in vertical CT imaging and adaptive radiotherapy. Methods The deep inspiration breath hold (DIBH) CT image and the end of exhalation (EE) phase image in four-dimensional CT of 14 thoracic cancer patients were used in this study. Lung volumes were manually delineated. A Demons-based deformable registration was first applied to register the EE CT to the DIBH CT for each patient, and the resulting deformation vector field deformed the EE CT image to the DIBH CT space. Given that the mass of the lung remains the same during respiration, we created a mass-preserving model to correlate lung density variations with volumetric changes, which were characterized by the Jacobian derived from the deformation field. The Jacobian determinant was used to correct the lung CT numbers transferred from the EE CT image. The absolute intensity differences created by subtracting the deformed EE CT from the DIBH CT with and without density correction were compared. Results The ratio of DIBH CT to EE CT lung volumes was 1.6 on average. The deformable registration registered the lung shape well, but the appearance of voxel intensities inside the lung was different, demonstrating the need for density correction. Without density correction, the mean and standard deviation of the absolute intensity difference between the deformed EE CT and the DIBH CT inside the lung were 54.5 +/- 45.5 for all cases. After density correction, these numbers decreased to 18.1 +/- 34.9, demonstrating greater accuracy. The cumulative histogram of the intensity difference also showed that density correction improved CT number mapping greatly. Conclusion Density correction improves CT number mapping inside the lung in deformable image registration for difficult cases with large lung volume differences.
引用
收藏
页码:2330 / 2336
页数:7
相关论文
共 50 条
  • [31] Validation of a deformable image registration technique for cone beam CT-based dose verification
    Moteabbed, M.
    Sharp, G. C.
    Wang, Y.
    Trofimov, A.
    Efstathiou, J. A.
    Lu, H. -M.
    MEDICAL PHYSICS, 2015, 42 (01) : 196 - 205
  • [32] Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic CT
    Vandemeulebroucke, Jef
    Bernard, Olivier
    Rit, Simon
    Kybic, Jan
    Clarysse, Patrick
    Sarrut, David
    MEDICAL PHYSICS, 2012, 39 (02) : 1006 - 1015
  • [33] Detection of vessel bifurcations in CT scans for automatic objective assessment of deformable image registration accuracy
    Cazoulat, Guillaume
    Anderson, Brian M.
    McCulloch, Molly M.
    Rigaud, Bastien
    Koay, Eugene J.
    Brock, Kristy K.
    MEDICAL PHYSICS, 2021, 48 (10) : 5935 - 5946
  • [34] A Deformable Image Registration Based Method to Assess Directionality of Thoracic Aortic Aneurysm Growth
    Bian, Zhangxing
    Zhong, Jiayang
    Hatt, Charles R.
    Burris, Nicholas S.
    MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596
  • [35] Deformable image registration of CT and truncated cone-beam CT for adaptive radiation therapy
    Zhen, Xin
    Yan, Hao
    Zhou, Linghong
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22) : 7979 - 7993
  • [36] Deformable image registration of CT images for automatic contour propagation in radiation therapy
    Wu, Qian
    Cao, Ruifen
    Pei, Xi
    Jia, Jing
    Hu, Liqin
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S1037 - S1044
  • [37] Accuracy of deformable image registration techniques for alignment of longitudinal cholangiocarcinoma CT images
    Sen, Anando
    Anderson, Brian M.
    Cazoulat, Guillaume
    McCulloch, Molly M.
    Elganainy, Dalia
    McDonald, Brigid A.
    He, Yulun
    Mohamed, Abdallah S. R.
    Elgohari, Baher A.
    Zaid, Mohamed
    Koay, Eugene J.
    Brock, Kristy K.
    MEDICAL PHYSICS, 2020, 47 (04) : 1670 - 1679
  • [38] Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers
    Wognum, S.
    Heethuis, S. E.
    Rosario, T.
    Hoogeman, M. S.
    Bel, A.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [39] Comparison of rigid and deformable image registration for nasopharyngeal carcinoma radiotherapy planning with diagnostic position PET/CT
    Kai, Yudai
    Arimura, Hidetaka
    Toya, Ryo
    Saito, Tetsuo
    Matsuyama, Tomohiko
    Fukugawa, Yoshiyuki
    Shiraishi, Shinya
    Shimohigashi, Yoshinobu
    Maruyama, Masato
    Oya, Natsuo
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (03) : 256 - 264
  • [40] Evaluation of deformable image registration and a motion model in CT images with limited features
    Liu, F.
    Hu, Y.
    Zhang, Q.
    Kincaid, R.
    Goodman, K. A.
    Mageras, G. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09) : 2539 - 2554