Technical Note: Density correction to improve CT number mapping in thoracic deformable image registration

被引:4
作者
Yang, Jinzhong [1 ]
Zhang, Yongbin [2 ]
Zhang, Zijian [1 ,3 ]
Zhang, Lifei [1 ]
Batter, Peter [1 ]
Court, Laurence [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Cincinnati, Proton Therapy Ctr, Med Ctr, Liberty Township, OH USA
[3] Cent S Univ, Xiangya Hosp, Changsha, Hunan, Peoples R China
基金
美国国家卫生研究院;
关键词
deformable image registration; density correction; Jacobian; lung cancer; NORMAL ORGAN WEIGHTS; II-THE-BRAIN; CANCER-PATIENTS; RADIOTHERAPY; CHAIR; VALIDATION; POSITION; SPLEEN; LUNGS; LIVER;
D O I
10.1002/mp.13502
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To improve the accuracy of computed tomography (CT) number mapping inside the lung in deformable image registration with large differences in lung volume for applications in vertical CT imaging and adaptive radiotherapy. Methods The deep inspiration breath hold (DIBH) CT image and the end of exhalation (EE) phase image in four-dimensional CT of 14 thoracic cancer patients were used in this study. Lung volumes were manually delineated. A Demons-based deformable registration was first applied to register the EE CT to the DIBH CT for each patient, and the resulting deformation vector field deformed the EE CT image to the DIBH CT space. Given that the mass of the lung remains the same during respiration, we created a mass-preserving model to correlate lung density variations with volumetric changes, which were characterized by the Jacobian derived from the deformation field. The Jacobian determinant was used to correct the lung CT numbers transferred from the EE CT image. The absolute intensity differences created by subtracting the deformed EE CT from the DIBH CT with and without density correction were compared. Results The ratio of DIBH CT to EE CT lung volumes was 1.6 on average. The deformable registration registered the lung shape well, but the appearance of voxel intensities inside the lung was different, demonstrating the need for density correction. Without density correction, the mean and standard deviation of the absolute intensity difference between the deformed EE CT and the DIBH CT inside the lung were 54.5 +/- 45.5 for all cases. After density correction, these numbers decreased to 18.1 +/- 34.9, demonstrating greater accuracy. The cumulative histogram of the intensity difference also showed that density correction improved CT number mapping greatly. Conclusion Density correction improves CT number mapping inside the lung in deformable image registration for difficult cases with large lung volume differences.
引用
收藏
页码:2330 / 2336
页数:7
相关论文
共 50 条
  • [21] Effect of Deformation Methods on the Accuracy of Deformable Image Registration From Kilovoltage CT to Tomotherapy Megavoltage CT
    Nobnop, Wannapha
    Chitapanarux, Imjai
    Wanwilairat, Somsak
    Tharavichitkul, Ekkasit
    Lorvidhaya, Vicharn
    Sripan, Patumrat
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [22] Benchmarking and performance evaluation of a novel deformable image registration software for radiotherapy CT images
    Alshammari, Shorug S.
    Yaddanapudi, Sridhar
    Ivancic, Rok
    Anderle, Kristjan
    Li, Jonathan G.
    Furutani, Keith M.
    Beltran, Chris J.
    Lu, Bo
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 32
  • [23] Open source deformable image registration system for treatment planning and recurrence CT scans
    Zukauskaite, Ruta
    Brink, Carsten
    Hansen, Christian Ronn
    Bertelsen, Anders
    Johansen, Jorgen
    Grau, Cai
    Eriksen, Jesper Grau
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (08) : 545 - 551
  • [24] Biomechanical deformable image registration of longitudinal lung CT images using vessel information
    Cazoulat, Guillaume
    Owen, Dawn
    Matuszak, Martha M.
    Balter, James M.
    Brock, Kristy K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13) : 4826 - 4839
  • [25] Clinical feasibility of MR-assisted CT-based cervical brachytherapy using MR-to-CT deformable image registration
    Dyer, Brandon A.
    Yuan, Zilong
    Qiu, Jianfeng
    Shi, Liting
    Wright, Cari
    Benedict, Stanley H.
    Valicenti, Richard
    Mayadev, Jyoti S.
    Rong, Yi
    BRACHYTHERAPY, 2020, 19 (04) : 447 - 456
  • [26] Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images
    Kadoya, Noriyuki
    Nakajima, Yujiro
    Saito, Masahide
    Miyabe, Yuki
    Kurooka, Masahiko
    Kito, Satoshi
    Fujita, Yukio
    Sasaki, Motoharu
    Arai, Kazuhiro
    Tani, Kensuke
    Yagi, Masashi
    Wakita, Akihisa
    Tohyama, Naoki
    Jingu, Keiichi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : 422 - 431
  • [27] The Feasibility of Mapping Dose Distribution of 4DCT Images with Deformable Image Registration in Lung
    Yu, Hui
    Zhang, Shu-xu
    Wang, Rui-hao
    Zhang, Guo-qian
    Tan, Jian-ming
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 145 - 153
  • [28] Evaluation of whole-body MR to CT deformable image registration
    Akbarzadeh, A.
    Gutierrez, D.
    Baskin, A.
    Ay, M. R.
    Ahmadian, A.
    Alam, N. Riahi
    Loevblad, K. O.
    Zaidi, H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 238 - 253
  • [29] Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms
    Latifi, Kujtim
    Forster, Kenneth M.
    Hoffe, Sarah E.
    Dilling, Thomas J.
    van Elmpt, Wouter
    Dekker, Andre
    Zhang, Geoffrey G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 150 - 162
  • [30] A vessel bifurcation liver CT landmark pair dataset for evaluating deformable image registration algorithms
    Zhang, Zhendong
    Criscuolo, Edward Robert
    Hao, Yao
    Mckeown, Trevor
    Yang, Deshan
    MEDICAL PHYSICS, 2024, : 703 - 715