Reliability and minimal detectable change of the mini-BESTest in adults with spinal cord injury in a rehabilitation setting

被引:15
|
作者
Roy, Audrey [1 ,2 ,3 ]
Higgins, Johanne [1 ,2 ,3 ]
Nadeau, Sylvie [1 ,2 ,3 ]
机构
[1] Univ Montreal, Fac Med, Sch Rehabil, Pavillon Parc,Bur 402-18,CP 6128 Succ Ctr Ville, Montreal, PQ H3C 3J7, Canada
[2] Ctr Interdisciplinary Res Rehabil Greater Montrea, Montreal, PQ, Canada
[3] IURDPM, Ctr Integre Univ Sante & Serv Soc, Ctr Sud De Ille De Montreal CCSMTL, Spinal Cord Injury Unit, Montreal, PQ, Canada
关键词
Reliability; Mini-BESTest; balance; spinal cord injuries; rehabilitation; BERG BALANCE SCALE; EVALUATION SYSTEMS TEST; INTERRATER RELIABILITY; PSYCHOMETRIC PROPERTIES; AMBULATORY PEOPLE; RASCH VALIDATION; POSTURAL CONTROL; VALIDITY; AGREEMENT; INDIVIDUALS;
D O I
10.1080/09593985.2019.1622161
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: The mini-Balance Evaluation Systems Test (mini-BESTest) is a valid tool for assessing standing balance in people with spinal cord injury (SCI). Its reliability has not yet been investigated with this population. Objective: To assess the test-retest and inter-rater reliability of the mini-BESTest in adults with SCI in a rehabilitation setting. Methods: Twenty-three participants admitted in a rehabilitation center following an SCI (mean age = 52.2 years, SD = 14.5; 13/23 tetraplegia; 14/23 traumatic injury) and able to stand 30 seconds without help were recruited. They were evaluated twice with the mini-BESTest to establish the test-retest reliability (interval of 1 to 2 days). One of the two sessions was video-recorded to establish the inter-rater reliability (3 physiotherapists). Intraclass correlation coefficients (ICC2,1), weighted kappa (K-w) and Kendall's W were used to determine reliability of total score and individual items. Minimal detectable changes (MDC) were computed. Results. The mini-BESTest total scores showed excellent test-retest (ICC = 0.94) and inter-rater (ICC = 0.96) reliability. Reliability of 50% of the individual items was acceptable to excellent (Kappa(w) and W = 0.35-1.00). The MDC of the mini-BESTest total score was 4 points. Conclusion: The mini-BESTest is a reliable tool to assess standing balance in adults with an SCI. A minimal change of 4 points on the total scale is needed to be confident that the change is not a measurement error between two sessions or two raters.
引用
收藏
页码:126 / 134
页数:9
相关论文
共 50 条
  • [31] Reliability and minimal detectable change of transcranial magnetic stimulation outcomes in healthy adults: A systematic review
    Beaulieu, Louis-David
    Flamand, Veronique H.
    Masse-Alarie, Hugo
    Schneider, Cyril
    BRAIN STIMULATION, 2017, 10 (02) : 196 - 213
  • [32] Test-Retest Reliability and Minimal Detectable Change Scores for Fitness Assessment in Older Adults with Type 2 Diabetes
    Alfonso-Rosa, Rosa M.
    del Pozo-Cruz, Borja
    del Pozo-Cruz, Jesus
    Sanudo, Borja
    Rogers, Michael E.
    REHABILITATION NURSING, 2014, 39 (05) : 260 - 268
  • [33] Depressive mood in adults with spinal cord injury as they transition from an inpatient to a community setting: secondary analyses from a clinical trial
    Craig, A.
    Guest, R.
    Tran, Y.
    Middleton, J.
    SPINAL CORD, 2017, 55 (10) : 926 - 934
  • [34] Test-retest reliability and minimal detectable change for measures of balance and gait in adults with cerebral palsy
    Levin, Ilana
    Lewek, Michael D.
    Giuliani, Carol
    Faldowski, Richard
    Thorpe, Deborah E.
    GAIT & POSTURE, 2019, 72 : 96 - 101
  • [35] Crohn's disease in a patient with acute spinal cord injury: A case report of diagnostic challenges in the rehabilitation setting
    Yung, JC
    Groah, SL
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (09): : 1274 - 1278
  • [36] Retrospective Analysis of Nosocomial Urinary Tract Infections with Spinal Cord Injury Patients in a Rehabilitation Setting
    Yilmaz, Bilge
    Yavuz, Ferdi
    Adiguzel, Emre
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2014, 60 (04): : 289 - 294
  • [37] Test-Retest Reliability and Minimal Detectable Change for the 10-Meter Walk Test in Older Adults With Parkinson's disease
    Lang, Jesse T.
    Kassan, Thomas O.
    Devaney, Laurie Lee
    Colon-Semenza, Cristina
    Joseph, Michael F.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2016, 39 (04) : 165 - 170
  • [38] Test-retest reliability and minimal detectable change of four functional tests in community-dwelling older adults with high risk of falls
    Intaruk, Roongnapa
    Phadungkit, Supaporn
    Kanpai, Anongnat
    Pawanta, Ketmanee
    Srihapol, Nuttanicha
    Saengsuwan, Jittima
    Amatachaya, Sugalya
    Thaweewannakij, Thiwabhorn
    TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2024, 70 (02) : 1 - 7
  • [39] Reliability, validity and sensitivity to change of neurogenic bowel dysfunction score in patients with spinal cord injury
    Erdem, D.
    Hava, D.
    Keskinoglu, P.
    Bircan, C.
    Peker, O.
    Krogh, K.
    Gulbahar, S.
    SPINAL CORD, 2017, 55 (12) : 1084 - 1087
  • [40] Patients' experiences with goal setting during initial rehabilitation after newly acquired spinal cord injury: A pilot qualitative interview study
    Lampart, Patricia
    Hausler, Florin
    Langewitz, Wolf
    Rubinelli, Sara
    Sigrist-Nix, Diana
    Scheel-Sailer, Anke
    JOURNAL OF SPINAL CORD MEDICINE, 2023, 46 (05) : 837 - 847