X-ray computed tomography using projection X-ray microscope

被引:1
|
作者
Yoshimura, F [1 ]
Miyata, C [1 ]
Kuzuryu, C [1 ]
Hori, A [1 ]
Obi, T [1 ]
Ohyama, N [1 ]
机构
[1] Meiji Univ, Dept Phys, Kawasaki, Kanagawa, Japan
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY III | 2002年 / 4503卷
关键词
X-ray microscope; projection X-ray microscope; computed tomography; micr-CT;
D O I
10.1117/12.452841
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have applied projection X-ray microscope for three-dimensional (3-D) structure analysis by means of cone-beam computed tomography. The projection images of small insect, Omiscus Porcellio, were recorded in every 1 degree for whole direction (360 degree) with a stepping motor controlled sample rotator. The images were recorded with cooled CCD camera (HAMAMATSU C4880) which detect X-ray directly. The 3-D image was reconstructed from corn-beam projections using back projection algorithm. The resolution of the reconstructed 3-D image (256 x 256 x 512 pixels) was about 20 mum. The digestive organs were clearly visualized in 3-D.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 50 条
  • [31] MINIMIZATION OF DOSE LOAD IN ALGORITHMS OF X-RAY COMPUTED TOMOGRAPHY
    Bulavin, L. A.
    Zabashta, Yu F.
    Motolyha, O., V
    UKRAINIAN JOURNAL OF PHYSICS, 2019, 64 (04): : 282 - 286
  • [32] Benchtop x-ray fluorescence computed tomography (XFCT) imaging
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [33] X-ray computed tomography based modelling of polymeric foams
    Wismans, J. G. F.
    van Dommelen, J. A. W.
    Govaert, L. E.
    Meijer, H. E. H.
    THERMEC 2009, PTS 1-4, 2010, 638-642 : 2761 - 2765
  • [34] Development of projection X-ray microscope with 100 nm spot size
    Matsunaga, Norihito
    Sato, Tomoya
    Higuchi, Kota
    Yamada, Atsushi
    NONDESTRUCTIVE TESTING AND EVALUATION, 2022, 37 (05) : 601 - 610
  • [35] Industrial X-ray computed tomography applied to paleobotanical research
    Pika-Biolzi, M
    Hochuli, PA
    Flisch, A
    RIVISTA ITALIANA DI PALEONTOLOGIA E STRATIGRAFIA, 2000, 106 (03) : 369 - 377
  • [36] Properties of preprocessed sinogram data in x-ray computed tomography
    Whiting, Bruce R.
    Massoumzadeh, Parinaz
    Earl, Orville A.
    O'Sullivan, Joseph A.
    Snyder, Donald L.
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2006, 33 (09) : 3290 - 3303
  • [37] Progress in Cell Marking for Synchrotron X-ray Computed Tomography
    Hall, Christopher
    Sturm, Erica
    Schultke, Elisabeth
    Arfelli, Fulvia
    Menk, Ralf-Hendrik
    Astolfo, Alberto
    Juurlink, Bernhard H. J.
    6TH INTERNATIONAL CONFERENCE ON MEDICAL APPLICATIONS OF SYNCHROTRON RADIATION, 2010, 1266 : 51 - +
  • [38] Computed tomography x-ray characterization: A Monte Carlo study
    Campos, Luciana Tourinho
    de Jesus, Fillipe Machado
    de Souza Goncalves, Elicardo Alves
    Goncalves Magalhaes, Luis Alexandre
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167 (167)
  • [39] Advances in X-ray detectors for clinical and preclinical Computed Tomography
    Panetta, Daniele
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 809 : 2 - 12
  • [40] Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
    Bai, Ti
    Wang, Biling
    Nguyen, Dan
    Wang, Bao
    Dong, Bin
    Cong, Wenxiang
    Kalra, Mannudeep K.
    Jiang, Steve
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (11) : 2965 - 2975