X-ray computed tomography using projection X-ray microscope

被引:1
|
作者
Yoshimura, F [1 ]
Miyata, C [1 ]
Kuzuryu, C [1 ]
Hori, A [1 ]
Obi, T [1 ]
Ohyama, N [1 ]
机构
[1] Meiji Univ, Dept Phys, Kawasaki, Kanagawa, Japan
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY III | 2002年 / 4503卷
关键词
X-ray microscope; projection X-ray microscope; computed tomography; micr-CT;
D O I
10.1117/12.452841
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have applied projection X-ray microscope for three-dimensional (3-D) structure analysis by means of cone-beam computed tomography. The projection images of small insect, Omiscus Porcellio, were recorded in every 1 degree for whole direction (360 degree) with a stepping motor controlled sample rotator. The images were recorded with cooled CCD camera (HAMAMATSU C4880) which detect X-ray directly. The 3-D image was reconstructed from corn-beam projections using back projection algorithm. The resolution of the reconstructed 3-D image (256 x 256 x 512 pixels) was about 20 mum. The digestive organs were clearly visualized in 3-D.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 50 条
  • [1] Evaluation of Gratings for X-ray and Neutron Phase Imaging Techniques by Using X-ray Projection Microscope
    Minami, Katsunori
    Yashiro, Wataru
    Olbinado, Margie
    Momose, Atsushi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 193 - 198
  • [2] X-Ray Acoustic Computed Tomography (XACT): 100% Sensitivity to X-Ray Absorption
    Xiang, L.
    Ahmad, M.
    Nikoozadeh, A.
    Pratx, G.
    Khuri-Yakub, B.
    Xing, L.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [3] Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source
    Saito, M
    MEDICAL PHYSICS, 2004, 31 (12) : 3436 - 3443
  • [4] Signal statistics of x-ray computed tomography
    Whiting, BR
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 53 - 60
  • [5] Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation
    Hayakawa, Y.
    Hayakawa, K.
    Inagaki, M.
    Kaneda, T.
    Nakao, K.
    Nogami, K.
    Sakae, T.
    Sakai, T.
    Sato, I.
    Takahashi, Y.
    Tanaka, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 230 - 236
  • [6] X-Ray Luminescence and X-Ray Fluorescence Computed Tomography: New Molecular Imaging Modalities
    Ahmad, Moiz
    Pratx, Guillem
    Bazalova, Magdalena
    Xing, Lei
    IEEE ACCESS, 2014, 2 : 1051 - 1061
  • [7] Adaptive zooming in X-ray computed tomography
    Dabravolski, Andrei
    Batenburg, Kees Joost
    Sijbers, Jan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 77 - 89
  • [8] Testing loaded samples using X-ray computed tomography
    Vasil'ev, S. L.
    Artem'ev, A. V.
    Bakulin, V. N.
    Yurgenson, S. A.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2016, 52 (05) : 294 - 302
  • [9] Testing loaded samples using X-ray computed tomography
    S. L. Vasil’ev
    A. V. Artem’ev
    V. N. Bakulin
    S. A. Yurgenson
    Russian Journal of Nondestructive Testing, 2016, 52 : 294 - 302
  • [10] Study of Soil Compaction Using X-Ray Computed Tomography
    Al-Hattamleh, O.
    Razavi, M. R.
    Muhunthan, B.
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2008, 2 (02) : 111 - 123