Patient's comfort with and tolerability of thyroid core needle biopsy

被引:54
作者
Nasrollah, Naim [1 ]
Trimboli, Pierpaolo [2 ]
Rossi, Fabio [2 ]
Amendola, Stefano [2 ]
Guidobaldi, Leo [3 ]
Ventura, Claudio [2 ]
Maglio, Riccardo [4 ]
Nigri, Giuseppe [4 ]
Romanelli, Francesco [5 ]
Valabrega, Stefano [4 ]
Crescenzi, Anna [3 ]
机构
[1] Osped Israelit, Sect Surg, Rome, Italy
[2] Osped Israelit Roma, Sect Endocrinol & Diabetol, I-00148 Rome, Italy
[3] Osped Israelit, Sect Pathol, Rome, Italy
[4] Univ Roma La Sapienza, Dept Surg & Med Sci, I-00185 Rome, Italy
[5] Univ Roma La Sapienza, Dept Expt Med, I-00185 Rome, Italy
关键词
Thyroid; Core needle biopsy (CNB); Fine-needle aspiration (FNA); Comfort; Tolerability; ASPIRATION BIOPSY; NODULES; COMPLICATIONS;
D O I
10.1007/s12020-013-9979-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recently, the core needle biopsy (CNB) has been proposed as a complementary test for thyroid nodules with inconclusive cytology by fine-needle aspiration (FNA). However, there have been no reports regarding patient comfort during and after CNB or tolerability of this procedure. Here we aimed to investigate and compare comfort with and tolerability of the CNB and FNA procedures. A 21 gauge needle was used for collection in CNB procedures, and a 23 gauge needle was used for collection in FNA procedures. Sixty-one consecutive patients underwent both biopsies and were asked to evaluate their comfort during and after these procedures by a structured questionnaire. A total of 58 (95 %) patients reported local pain during both biopsies. Two patients reported pain only during CNB, and one reported no pain. Mild pain was reported in 87 % of CNB cases. Local pain after biopsy was reported in 29 % of FNA and 45 % of CNB. The occurrence of pain in the first minutes following CNB was significantly higher than FNA (p = 0.008), while there was not a significant difference in pain at later time points after the procedures. Finally, patients were asked to evaluate the degree of tolerability of the two sampling techniques, and FNA and CNB were reported as tolerable in 82 and 83 %, respectively. The results from a questionnaire evaluating patients' comfort level showed no significant difference between the tolerability of CNB and FNA. This finding suggests that CNB may be performed with a reasonable level of patient comfort.
引用
收藏
页码:79 / 83
页数:5
相关论文
共 24 条
[1]   Large needle aspiration biopsy for reducing the rate of inadequate cytology on fine needle aspiration specimens from palpable thyroid nodules [J].
Carpi, A ;
Sagripanti, A ;
Nicolini, A ;
Santini, S ;
Ferrari, E ;
Romani, R ;
Di Coscio, G .
BIOMEDICINE & PHARMACOTHERAPY, 1998, 52 (7-8) :303-307
[2]   Complex thyroid nodules with nondiagnostic fine needle aspiration cytology: histopathologic outcomes and comparison of the cytologic variants (cystic vs. acellular) [J].
Garcia-Pascual, Luis ;
Barahona, Maria-Jose ;
Balsells, Montserrat ;
del Pozo, Carlos ;
Anglada-Barcelo, Jordi ;
Casalots-Casado, Jaume ;
Veloso, Enrique ;
Torres, Juan .
ENDOCRINE, 2011, 39 (01) :33-40
[3]   FINE-NEEDLE ASPIRATION BIOPSY OF THE THYROID - AN APPRAISAL [J].
GHARIB, H ;
GOELLNER, JR .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (04) :282-289
[4]  
Gharib Hossein, 2010, Endocr Pract, V16, P468
[5]   Needle-free delivery of lidocaine for reducing the pain associated with the fine-needle aspiration biopsy of thyroid nodules: Time-saving and efficacious procedure [J].
Gursoy, Alptekin ;
Ertugrul, Derun Taner ;
Sahin, Mustafa ;
Tutuncu, Neslihan Bascil ;
Demirer, Asli Nar ;
Demirag, Nilgun Guvener .
THYROID, 2007, 17 (04) :317-321
[6]   The analgesic efficacy of lidocaine/prilocaine (EMLA) cream during fine-needle aspiration biopsy of thyroid nodules [J].
Gursoy, Alptekin ;
Ertugrul, Derun Taner ;
Sahin, Mustafa ;
Tutuncu, Neslihan Bascil ;
Demirer, Asli Nar ;
Demirag, Nilgun Guvener .
CLINICAL ENDOCRINOLOGY, 2007, 66 (05) :691-694
[7]   FINE-NEEDLE ASPIRATION BIOPSY OF THYROID-NODULES - IMPACT ON THYROID PRACTICE AND COST OF CARE [J].
HAMBERGER, B ;
GHARIB, H ;
MELTON, LJ ;
GOELLNER, JR ;
ZINSMEISTER, AR .
AMERICAN JOURNAL OF MEDICINE, 1982, 73 (03) :381-384
[8]   Bilateral thyroid hematomas after fine-needle aspiration causing acute airway obstruction [J].
Hor, Tiffany ;
Lahiri, Sharon Wu .
THYROID, 2008, 18 (05) :567-569
[9]   The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules [J].
Inci, Mehmet Fatih ;
Ozkan, Fuat ;
Yuksel, Murvet ;
Salk, Ismail ;
Sahin, Murat .
ENDOCRINE, 2013, 43 (02) :424-429
[10]   Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture? [J].
Kim, Dong Wook ;
Rho, Myung Ho ;
Kim, Ki Nam .
KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (05) :441-446