Preliminary characterization of a dual-source passive building cooling system based on loop thermosyphon

被引:14
作者
Cao, Jingyu [1 ,2 ]
Zheng, Ling [1 ]
Peng, Jinqing [1 ,2 ]
Luo, Yimo [1 ]
Hu, Mingke [3 ]
Wang, Qiliang [4 ]
Pei, Gang [5 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha, Hunan, Peoples R China
[3] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[4] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[5] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230027, Peoples R China
关键词
Energy-efficient building; Loop thermosyphon; Sky radiative cooling; Evaporative cooling; REFRIGERATION;
D O I
10.1016/j.enbuild.2022.111981
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Passive cooling technique is an efficient way to avoid the high energy consumption of conventional air conditioner in heat dissipation of industrial buildings, in which loop thermosyphon has shown an attractive application prospect. But the normal loop thermosyphon cooler only relies on the air source heat exchange, and an obvious performance degradation will occur when the ambient temperature is high. In this paper, a new scheme combining sky radiative cooling and direct evaporative cooling for the passive condenser heat dissipation of loop thermosyphon is put forward. The characteristics of this dualsource passive building cooling system is simulative investigated. The effects of ambient temperature, ambient relative humidity, indoor air temperature, evaporator air velocity, and solar radiation intensity are discussed in detail to determine its thermal characteristics. The system exhibits a relatively stable heat exchange capacity of 398.3 - 505.6 W at various outdoor boundary conditions and a preferable cooling performance under high ambient temperature in comparison with conventional air source loop thermosyphon cooler. The thermal analyses show that coupling of sky radiative cooling and direct evaporative cooling with a loop thermosyphon enables high cooling capability in normal working conditions to accomplish indoor thermal comfort. Results demonstrate effectiveness of the proposed system on achieving reliable, sustainable, and efficient passive cooling for industrial buildings. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:13
相关论文
共 43 条
[21]   Feasibility research on a double-covered hybrid photo-thermal and radiative sky cooling module [J].
Hu, Mingke ;
Zhao, Bin ;
Ao, Xianze ;
Chen, Nuo ;
Cao, Jingyu ;
Wang, Qiliang ;
Su, Yuehong ;
Pei, Gang .
SOLAR ENERGY, 2020, 197 :332-343
[22]   Study on the performance of two water-side free cooling methods in a semiconductor manufacturing factory [J].
Jia, Lizhi ;
Liu, Junjie ;
Wei, Shen ;
Xu, Jing .
ENERGY AND BUILDINGS, 2021, 243
[23]   An investigation into sky temperature estimation, its variation, and significance in heat transfer calculations of solar cookers [J].
Karn, Ashish ;
Chintala, Venkateshwarlu ;
Kumar, Suresh .
HEAT TRANSFER-ASIAN RESEARCH, 2019, 48 (05) :1830-1856
[24]   Sustainable cooling system for Kuwait hot climate combining diurnal radiative cooling and indirect evaporative cooling system [J].
Katramiz, Elvire ;
Al Jebaei, Hussein ;
Alotaibi, Sorour ;
Chakroun, Walid ;
Ghaddar, Nesreen ;
Ghali, Kamel .
ENERGY, 2020, 213
[25]  
Li W., 1997, CHIN J MECH ENG-EN, V31, P604
[26]   Refrigeration characteristics of a hybrid heat dissipation photovoltaic-thermal heat pump under various ambient conditions on summer night [J].
Lu, Shixiang ;
Zhang, Jili ;
Liang, Ruobing ;
Zhou, Chao .
RENEWABLE ENERGY, 2020, 146 :2524-2534
[27]  
[罗庆 LUO Qing], 2009, [功能材料, Journal of Functional Materials], V40, P1023
[28]   A novel strategy of enhancing sky radiative cooling by solar photovoltaic-thermoelectric cooler [J].
Lv, Song ;
Ji, Yishuang ;
Qian, Zuoqin ;
He, Wei ;
Hu, Zhongting ;
Liu, Minghou .
ENERGY, 2021, 219
[29]   A simplified numerical model for evaporative cooling by water spray over roof surfaces [J].
Nayak, Ajaya Ketan ;
Hagishima, Aya ;
Tanimoto, Jun .
APPLIED THERMAL ENGINEERING, 2020, 165
[30]   Experiments with a 'psychrometric' roof pond system for passive cooling in hot-arid regions [J].
Pearlmutter, David ;
Berliner, Pedro .
ENERGY AND BUILDINGS, 2017, 144 :295-302