Similarity of coupled heat and mass transfer between air-water and air-liquid desiccant direct-contact systems

被引:39
作者
Liu, Xiao-Hua [1 ]
Li, Zhen [2 ]
Jiang, Yi [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Engn Mech, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat and mass transfer; Liquid desiccant/water; Reachable handling region; Zonal method; Flow pattern; Air-conditioning; COOLING-TOWER; DEHUMIDIFIER/REGENERATOR; DEHUMIDIFICATION; REGENERATION; PERFORMANCE; COOLER;
D O I
10.1016/j.buildenv.2009.04.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Packed-bed heat and mass transfer devices are widely used in air-conditioning systems, such as cooling tower, evaporative cooler of air-water direct-contact devices, dehumidifier and regenerator of air-liquid desiccant direct-contact devices. Similarities of heat and mass transfer characteristics between air-water and air-liquid desiccant devices are considered and investigated in this paper. Same reachable handling region of outlet air can be obtained for both air-water and air-liquid desiccant devices. which is among three boundarylines, isenthalpic line of inlet air, iso-relative humidity line of inlet fluid (water or desiccant), and the connecting line of inlet statuses of air and fluid. Inlet conditions of air and fluid affect heat and mass transfer characteristics to some extent. so that a zonal method is proposed only according to the relative statuses of inlet air to inlet fluid. Four zones, dehumidification zones A, D and regeneration zones B, C, are divided for air-desiccant direct-contact devices. The first three zones A, B and C are divided for air-water direct-contact devices, with the same zonal properties as those of air-desiccant devices. In order to obtain better humidification performance, fluid should be heated (in zone C) rather than air(in zone B). And fluid should be cooled (in zone A) rather than air (in zone D) to obtain better dehumidification performance. Counter-flow pattern should be applied for best mass transfer performance in the same conditions within the recommended zone A or C, while parallel-flow pattern is the best in zone B or D. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2501 / 2509
页数:9
相关论文
共 16 条
[1]   Theoretical study on a cross-flow direct evaporative cooler using honeycomb paper as packing material [J].
Dai, YJ ;
Sumathy, K .
APPLIED THERMAL ENGINEERING, 2002, 22 (13) :1417-1430
[2]   Study of an aqueous lithium chloride desiccant system: Air dehumidification and desiccant regeneration [J].
Fumo, N ;
Goswami, DY .
SOLAR ENERGY, 2002, 72 (04) :351-361
[3]  
GE KS, 1999, J CHINA AGR U, V4, P82
[4]   Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant [J].
Liu, X. H. ;
Jiang, Y. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) :1357-1366
[5]   Analytical solutions of coupled heat and mass transfer processes in liquid desiccant air dehumidifier/regenerator [J].
Liu, Xiaohua ;
Jiang, Yi ;
Xia, Jianjun ;
Chang, Xiaomin .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (07) :2221-2232
[6]   COEFFICIENTS OF HEAT AND MASS-TRANSFER IN A PACKED-BED SUITABLE FOR SOLAR REGENERATION OF AQUEOUS LITHIUM-CHLORIDE SOLUTIONS [J].
LOF, GOG ;
LENZ, TG ;
RAO, S .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (04) :387-392
[7]  
LU YQ, 2008, DESIGN HDB HEATING V
[8]   Comparative experimental drift study between a dry and adiabatic fluid cooler and a cooling tower [J].
Lucas, M. ;
Martinez, P. J. ;
Viedma, A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1169-1175
[9]   Effects of inlet relative humidity and inlet temperature on the performance of counterflow wet cooling tower based on exergy analysis [J].
Muangnoi, Thirapong ;
Asvapoositkul, Wanchai ;
Wongwises, Somchai .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) :2795-2800
[10]   PERFORMANCE STUDIES FOR AN EXPERIMENTAL SOLAR OPEN-CYCLE LIQUID DESICCANT AIR DEHUMIDIFICATION SYSTEM [J].
PATNAIK, S ;
LENZ, TG ;
LOF, GOG .
SOLAR ENERGY, 1990, 44 (03) :123-135