Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation

被引:25
|
作者
Pedulla, E. [1 ]
Lizio, A. [2 ]
Scibilia, M. [1 ]
Grande, N. M. [3 ]
Plotino, G. [4 ]
Boninelli, S. [5 ]
Rapisarda, E. [1 ]
Lo Giudice, G. [2 ]
机构
[1] Univ Catania, Dept Gen Surg & Surg Med Specialties, Catania, Italy
[2] Univ Messina, Sch Dent, Dept Conservat Dent, Messina, Italy
[3] Univ Cattolica Sacro Cuore, Rome, Italy
[4] Univ Roma La Sapienza, CLID, Isernia, Italy
[5] CNR, MATIS Inst Microelect & Microsyst, Catania, Italy
关键词
cyclic fatigue resistance; interrupted rotation; Mtwo; NiTi fracture; ProTaper Next; ROOT-CANAL PREPARATION; SHAPE-MEMORY ALLOYS; CLINICAL-USE; FRACTURE; FILES; PROTAPER; DEFECTS; TRANSFORMATION; SYSTEMS; NITINOL;
D O I
10.1111/iej.12609
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To investigate the influence of interrupted rotation on cyclic fatigue of two nickel-titanium rotary instruments. Methodology Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10,.04 taper; size 15,.05 taper; size 20,.06 taper and size 25,.06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60 degrees angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. Results Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25,.06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). Conclusions Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25,.06 taper, especially when a higher number of interruptions was performed.
引用
收藏
页码:194 / 201
页数:8
相关论文
共 50 条
  • [1] A comparison of cyclic fatigue resistance in reciprocating and rotary nickel-titanium instruments
    Wan, Jeffrey
    Rasimick, Brian J.
    Musikant, Barry L.
    Deutsch, Allan S.
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (03) : 122 - 127
  • [2] Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments
    Capar, Ismail Davut
    Ertas, Huseyin
    Arslan, Hakan
    AUSTRALIAN ENDODONTIC JOURNAL, 2015, 41 (01) : 24 - 28
  • [3] Effect of interrupted motion on the cyclic fatigue resistance of reciprocating nickel-titanium instruments
    Keskin, C.
    Inan, U.
    Demiral, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (05) : 549 - 555
  • [4] Response: Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary instruments
    Elnaghy, A. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1101 - 1101
  • [5] Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    Tripi, Teresa Roberta
    Bonaccorso, Antonio
    Condorelli, Guglielmo Guido
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : E106 - E114
  • [6] A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments
    Plotino, Gianluca
    Grande, Nicola M.
    Cordaro, Massimo
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2009, 35 (11) : 1469 - 1476
  • [7] Cyclic Fatigue Resistance of Rotary Nickel-Titanium Instruments Submitted to Nitrogen Ion Implantation
    Gavini, Giulio
    Pessoa, Oscar Faciola
    Barletta, Fernando Branco
    Vasconcellos, M. A. Z.
    Caldeira, Celso Luiz
    JOURNAL OF ENDODONTICS, 2010, 36 (07) : 1183 - 1186
  • [8] Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments
    Ounsi, Hani F.
    Salameh, Ziad
    Al-Shalan, Thakib
    Ferrari, Marco
    Grandini, Simone
    Pashley, David H.
    Tay, Franklin R.
    JOURNAL OF ENDODONTICS, 2007, 33 (06) : 737 - 741
  • [9] Cyclic Fatigue Resistance of Nickel-Titanium Rotary Instruments after Simulated Clinical Use
    Ubaed, Hana R.
    Bakr, Diyar Kh.
    APPLIED BIONICS AND BIOMECHANICS, 2022, 2022
  • [10] Influence of continuous rotation or reciprocation of Optimum Torque Reverse motion on cyclic fatigue resistance of nickel-titanium rotary instruments
    Pedulla, E.
    Corsentino, G.
    Ambu, E.
    Rovai, F.
    Campedelli, F.
    Rapisarda, S.
    La Rosa, G. R.
    Rapisarda, E.
    Grandini, S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (05) : 522 - 528