Temperature Measurement During Polymerization of Bone Cement in Percutaneous Vertebroplasty: An In Vivo Study in Humans

被引:55
作者
Anselmetti, Giovanni Carlo [1 ]
Manca, Antonio [1 ,2 ]
Kanika, Khanna [3 ]
Murphy, Kieran [3 ]
Eminefendic, Haris [4 ]
Masala, Salvatore [5 ]
Regge, Daniele [4 ]
机构
[1] IRCC, Intervent Radiol Unit, I-10060 Turin, Italy
[2] Univ Sassari, I-07100 Sassari, Italy
[3] Johns Hopkins Univ Hosp, Baltimore, MD 21287 USA
[4] IRCC, Radiol Unit, I-10060 Turin, Italy
[5] Univ Roma Tor Vergata, Gen Hosp, Dept Diagnost Imaging Mol Imaging Intervent Radio, I-00133 Rome, Italy
关键词
Vertebroplasty; Bone cement; Temperature; Polymethylmethacrylate; Radiofrequency ablation; OSTEOPOROTIC COMPRESSION FRACTURES; VERTEBRAL BODY; POLYMETHYL-METHACRYLATE; PULMONARY-EMBOLISM; POLYMETHYLMETHACRYLATE; ABLATION; MANAGEMENT; ELEVATION; EFFICACY;
D O I
10.1007/s00270-009-9509-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim of the study was to "in vivo" measure temperature, during percutaneous vertebroplasty (PV), within a vertebral body injected with different bone cements. According to the declaration of Helsinki, 22 women (60-80 years; mean, 75 years) with painful osteoporotic vertebral collapse underwent bilateral transpedicular PV on 22 lumbar vertebrae. Two 10-G vertebroplasty needles were introduced into the vertebra under digital fluoroscopy; a 16-G radiofrequency thermoablation needle (Starburst XL; RITA Medical System Inc., USA), carrying five thermocouples, was than coaxially inserted. Eleven different bone cements were injected and temperatures were measured every 30 s until temperatures dropped under 45A degrees C. After the thermocouple needle was withdrawn, bilateral PV was completed with cement injection through the vertebroplasty needle. Unpaired Student's t-tests, Kruskal-Wallis test, and Wilcoxon signed rank test were used to evaluate significant differences (p < 0.05) in peak temperatures, variations between cements, and clinical outcome. All procedures were completed without complications, achieving good clinical outcomes (p < 0.0001). Regarding average peak temperature, cements were divided into three groups: A (over 60A degrees C), B (from 50A degrees to 60A degrees C), and C (below 50A degrees C). Peak temperature in Group A (86.7 +/- A 10.7A degrees C) was significantly higher (p = 0.0172) than that in Groups B (60.5 +/- A 3.7A degrees C) and C (44.8 +/- A 2.6A degrees C). The average of all thermocouples showed an extremely significant difference (p = 0.0002) between groups. None of the tested cements maintained a temperature a parts per thousand yen45A degrees C for more than 30 min. These data suggest that back-pain improvement is obtained not by thermal necrosis but by mechanical consolidation only. The relative necrotic thermal effect in vertebral metastases seems to confirm that analgesia must be considered the main intent of PV.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 41 条
[1]  
Antonacci MD, 1998, J SPINAL DISORD, V11, P526
[2]   Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[3]   Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[4]   Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty [J].
Belkoff, SM ;
Molloy, S .
SPINE, 2003, 28 (14) :1555-1559
[5]  
BELKOFF SM, 1999, BONE S, V25, P23
[6]  
Berman AT., 1984, CLIN ORTHOP RELAT R, V186, P284
[7]  
Bostrom MP, 1997, SPINE S, V22, P38, DOI DOI 10.1097/00007632-199712151-00007
[8]   Treatment of chronic symptomatic vertebral compression fractures with percutaneous vertebroplasty [J].
Brown, DB ;
Gilula, LA ;
Sehgal, M ;
Shimony, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (02) :319-322
[9]   Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty [J].
Choe, DH ;
Marom, EM ;
Ahrar, K ;
Truong, MT ;
Madewell, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (04) :1097-1102
[10]   Temperature elevation caused by bone cement polymerization during vertebroplasty [J].
Deramond, H ;
Wright, NT ;
Belkoff, SM .
BONE, 1999, 25 (02) :17S-21S