Direct digital lateral cephalometry: The effects of JPEG compression on image quality

被引:7
作者
Wenger, N. A. [1 ]
Tewson, D. H. T. K. [1 ]
McDonald, F. [1 ]
机构
[1] Kings Coll, GKT Dent Inst, London, England
关键词
direct digital lateral cephalometry; JPEG compression; image quality;
D O I
10.1016/j.medengphy.2005.09.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: This study used an aluminium test object to assess the effect of the Joint Photographics Expert Group (JPEG) compression algorithm, on direct digital cephalometric image quality. Methods: The aluminium block of 15 steps, with 20 holes in each step was radiographed in a Planmeca Proline 2002 digital cephalometric machine with Dimaxis2 software. Six different JPEG compression ratios were used to capture the cephalometric images. These ratios were 60%, 70%, 80%, 90%, TOP QUALITY JPEG (TQJPEG 98%) and TIFF (uncompressed). The images were taken at 68 kV and 12 mA with a 7 s exposure. Six experienced observers viewed the monitor displayed images, which were presented randomly. This was repeated one month later. The number of holes detected by each observer was plotted against each compression ratio. Intra-observer and inter-observer reproducibility was calculated using the Mann-Whitney U-test. Differences between the compression ratios were assessed using a Kruskal-Wallis one-way analysis of variance. Results: When comparing intra-observer reproducibility, it was found that there were only four of 36 comparisons that showed a statistically significant difference (Observer 1: 60% (P = 0.004), TQJPEG (P = 0.019); Observer 2: TIFF (P = 0.005); Observer 3: 90% (P = 0.007)). Statistically, there was no significant difference with inter-observer reproducibility. There was no statistically significant difference between the image quality obtained from each compression ratio. Conclusions:. The results showed that JPEG compression does not have any effect on the perceptibility of landmarks in the aluminium test object used in this study. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:560 / 567
页数:8
相关论文
共 10 条
[1]  
Brennan J, 2002, J Orthod, V29, P66, DOI 10.1093/ortho/29.1.66
[2]  
Broadbent BH., 1931, Angle Orthod, V1, P45, DOI DOI 10.1043/0003-3219(1931)001<0045:ANXTAI>2.0.CO
[3]  
2
[4]   Comparative evaluation of JPEG and JPEG2000 compression in quantitative digital subtraction radiography [J].
Fidler, A ;
Likar, B ;
Pernus, F ;
Skaleric, U .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (06) :379-384
[5]   Effect of noise on the compressibility and diagnostic accuracy for caries detection of digital bitewing radiographs [J].
Janhom, A ;
van der Stelt, PF ;
van Ginkel, FC ;
Geraets, WGM .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (01) :6-12
[6]  
KUNDEL HL, 1986, RADIOL CLIN N AM, V24, P69
[7]  
Sanderink G. C. H., 1997, V1143, P299
[8]  
VANDERSTELT PF, 1997, J DENT RES, V76, P1101
[9]  
WHAITES E, 1996, ESSENTIALS DENTAL RA, P135
[10]   Prediction of Perceptibility Curves of direct digital intraoral radiographic systems [J].
Yoshiura, K ;
Stamatakis, HC ;
Welander, U ;
McDavid, WD ;
Shi, XQ ;
Ban, S ;
Kawazu, T ;
Chikui, T ;
Kanda, S .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :224-231