Safety and Efficacy of the Neuroform Atlas Stent for Treatment of Intracranial Aneurysms A Systematic Review and Meta-Analysis

被引:12
作者
Lynch, Jeremy [1 ]
Sciacca, Sara [2 ]
Siddiqui, Juveria [2 ]
Kanagarajah, Lakshmi [1 ]
Derakhshani, Shahram [1 ]
机构
[1] Queens Univ Hosp, Essex Ctr Neurol Sci, Neurointervent Radiol, Romford RM7 0AG, Greater London, England
[2] Kings Coll Hosp London, Neuroradiol, Denmark Hill, London SE5 9RS, England
关键词
Stroke; Coil; Haemorrhage; ASSISTED COILING; ENDOVASCULAR TREATMENT; LOW-PROFILE; EMBOLIZATION;
D O I
10.1007/s00062-020-00979-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective The Neuroform Atlas (Stryker Neurovascular, Fremont, CA, USA) is a low-profile laser cut self-expanding nitinol stent designed to provide coil support and wall apposition during aneurysm embolisation. In this study, we performed a meta-analysis of outcomes after treatment with the Neuroform Atlas stent for the purpose of coil embolisation. Methods The primary objectives of this meta-analysis were to define the safety (treatment-related complications, neurologic outcomes, mortality rate) and the efficacy (aneurysm occlusion rate) of the treatment of intracranial aneurysms with the Neuroform Atlas stent. A systematic review and meta-analysis was performed by searching PubMed, EMBASE, and the Cochrane CENTRAL Library for all published studies on the treatment of intracranial aneurysms with the Neuroform Atlas device up to 6 April 2020. The review was prepared in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Results A total of 14 studies were analysed (577 patients with 593 intracranial aneurysms). The mean age was 58.2 years and 35.6% were male. Technical success of the procedure was 100%. RROC1/RROC2 (Raymond-Roy occlusion classification (RROC) 1/2) (total occlusion/neck remnant) at a mean follow-up of 8.9 months was achieved in 94.8%. RROC3 was 4.9%. All-cause mortality was 1.8% and permanent residual neurological deficit or disability was 2.7%. Overall complications at follow-up were 6.2%. Conclusion Our analysis demonstrated good rates of occlusion at follow-up for aneurysms treated with the Atlas device at follow-up. The safety profile appears similar to other low-profile intracranial stents.
引用
收藏
页码:1167 / 1180
页数:14
相关论文
共 50 条
  • [31] Rescue Stenting Using Neuroform Atlas Stent During Coiling Protrusion for Ruptured Intracranial Aneurysms
    Semeraro, Vittorio
    Ganimede, Maria Porzia
    Lucarelli, Nicola Maria
    Lozupone, Emilio
    Vidali, Sofia
    Gisone, Vito
    Burdi, Nicola
    WORLD NEUROSURGERY, 2019, 128 : E454 - E460
  • [32] Y-Stent-Assisted Coiling of Wide-Necked Intracranial Aneurysms With the Neuroform Atlas Stent System
    Jadhav, Ashutosh P.
    Desai, Shashvat M.
    Jovin, Tudor G.
    Hanel, Ricardo A.
    Sauvageau, Eric A.
    Aghaebrahim, Amin
    Lin, Eugene
    Khaldi, Ahmad
    Gupta, Rishi G.
    Johnson, Andrew K.
    Frei, Donald
    Loy, David
    Malek, Adel
    Toth, Gabor
    Siddiqui, Adnan
    Reavey-Cantwell, John
    Thomas, Ajith
    Hetts, Steven W.
    Zaidat, Osama O.
    Jankowitz, Brian T.
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (01):
  • [33] Neuroform atlas stent-assisted coiling of tiny wide-necked intracranial aneurysms
    Dong, Linggen
    Chen, Xiheng
    Wang, Jiejun
    Zhang, Longhui
    Zhao, Zhiqiang
    Peng, Qichen
    Liu, Peng
    Lv, Ming
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [34] Comparison of the safety and efficacy of Neuroform Atlas stent deployed via Gateway balloon catheter and microcatheter for the treatment of intracranial stenosis
    Zhu, Deyuan
    Qi, Dayong
    Cao, Wei
    Hu, Rongguo
    Zhang, Kangqing
    Song, Tonghui
    Ma, Peipei
    Zheng, Tianheng
    Fang, Yibin
    JOURNAL OF NEURORADIOLOGY, 2024, 51 (04)
  • [35] Safety and efficacy of treatment strategies for posterior inferior cerebellar artery aneurysms: a systematic review and meta-analysis
    Ondra Petr
    Alena Sejkorová
    Ondřej Bradáč
    Waleed Brinjikji
    Giuseppe Lanzino
    Acta Neurochirurgica, 2016, 158 : 2415 - 2428
  • [36] Safety and efficacy of treatment strategies for posterior inferior cerebellar artery aneurysms: a systematic review and meta-analysis
    Petr, Ondra
    Sejkorova, Alena
    Bradac, Ondrej
    Brinjikji, Waleed
    Lanzino, Giuseppe
    ACTA NEUROCHIRURGICA, 2016, 158 (12) : 2415 - 2428
  • [37] Stent-assistant versus non-stent-assistant coiling for ruptured and unruptured intracranial aneurysms: A meta-analysis and systematic review
    Nabizadeh, Fardin
    Valizadeh, Parya
    Balabandian, Mohammad
    WORLD NEUROSURGERY-X, 2024, 21
  • [38] Efficacy and Safety of Different Bioactive Coils in Intracranial Aneurysm Interventional Treatment, a Systematic Review and Bayesian Network Meta-Analysis
    Zhang, Jie
    Jiang, Guannan
    Song, Zhaoming
    Cheng, Wei
    Wu, Wenxue
    Chen, Zhouqing
    Wang, Zhong
    You, Wanchun
    Chen, Gang
    BRAIN SCIENCES, 2022, 12 (08)
  • [39] Efficacy and safety of endovascular treatment for patients with acute intracranial atherosclerosisrelated posterior circulation stroke: a systematic review and meta-analysis
    Bao, Jiajia
    Hong, Ye
    Cui, Chaohua
    Ma, Mengmeng
    Gao, Lijie
    Liu, Qian
    Chen, Ning
    He, Li
    REVIEWS IN THE NEUROSCIENCES, 2021, 32 (01) : 11 - 22
  • [40] Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review
    Lv, Xianli
    Yang, Hongchao
    Liu, Peng
    Li, Youxiang
    NEURORADIOLOGY JOURNAL, 2016, 29 (01) : 66 - 71