Comparative Performance of Philic and Phobic Oil-Mist Filters

被引:71
作者
Mullins, Benjamin J. [1 ,2 ]
Mead-Hunter, Ryan [1 ,2 ]
Pitta, Renato N. [3 ]
Kasper, Gerhard [3 ]
Heikamp, Wolfgang [4 ]
机构
[1] Curtin Univ, Sch Publ Hlth, Fac Hlth Sci, Perth, WA 6845, Australia
[2] Curtin Univ, Fluid Dynam Res Grp, Perth, WA 6845, Australia
[3] Karlsruhe Inst Technol, Inst Mech Proc Engn & Mech MVM, D-76131 Karlsruhe, Germany
[4] Rhodius GmbH, D-91781 Weissenburg, Germany
基金
澳大利亚研究理事会;
关键词
oil-mist; filter; saturation; equilibrium; efficiency; MULTIMODAL CALIBRATION METHOD; OPTICAL-PARTICLE COUNTERS; FIBROUS FILTERS; WET FILTERS; LIQUID SATURATION; VERTICAL FIBERS; DRAG FORCES; FILTRATION; DROPLETS; AEROSOLS;
D O I
10.1002/aic.14479
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The evolution of pressure drop, drainage rate, saturation, and efficiency of combined philic, and phobic oil mist filters in real-time are examined. The experiments used four different filter configurations, with a combination of oleophobic and oleophilic fibrous filter media, and one oleophilic only reference. The effect of separating filter materials of differing wettability, with a mesh, was also explored. It was found that inclusion of a mesh between layers promoted increased drainage rates and resulted in a significantly lower pressure drop across the filter. The overall mass-based filtration efficiency was also slightly higher for the configurations containing the mesh. Conversely, re-entrainment of droplets from the rear face of the filter was only observed in filter configurations without the central mesh. Filters with oleophobic initial layers did not display a classical "depth filtration" pressure drop curve. The oleophobic media was found to possess lower steady-state saturation than oleophilic media. Additionally, the steady-state saturation of the oleophilic filter media, when placed at the rear of the filter, was lower when the central mesh was present. The saturation values were compared with recently published theory. (C) 2014 American Institute of Chemical Engineers
引用
收藏
页码:2976 / 2984
页数:9
相关论文
共 31 条
[1]   Filtration of liquid aerosols on nonwettable fibrous filters [J].
Agranovski, IE ;
Braddock, RD .
AICHE JOURNAL, 1998, 44 (12) :2784-2790
[2]   Clogging of wet filters by dust particles [J].
Agranovski, IE ;
Shapiro, M .
JOURNAL OF AEROSOL SCIENCE, 2001, 32 (08) :1009-1020
[3]  
Agranovski IE, 2001, CHEM ENG TECHNOL, V24, P387, DOI 10.1002/1521-4125(200104)24:4<387::AID-CEAT387>3.3.CO
[4]  
2-8
[5]  
Agranovski IE, 2001, CHEM ENG TECHNOL, V24, P287, DOI 10.1002/1521-4125(200103)24:3<287::AID-CEAT287>3.0.CO
[6]  
2-P
[7]   Continuum model evaluation of the effect of saturation on coalescence filtration [J].
Andan, S. ;
Hariharan, S. I. ;
Chase, G. G. .
SEPARATION SCIENCE AND TECHNOLOGY, 2008, 43 (08) :1955-1973
[8]   Filtration of soot-in-oil aerosols: Why do field and laboratory experiments differ? [J].
Bredin, Arne ;
O'Leary, Rebecca A. ;
Mullins, Benjamin J. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 96 :107-116
[9]   Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters [J].
Bredin, Arne ;
Mullins, Benjamin J. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 90 :53-63
[10]   Experimental and modelled efficiencies during the filtration of a liquid aerosol with a fibrous medium [J].
Charvet, A. ;
Gonthier, Y. ;
Gonze, E. ;
Bernis, A. .
CHEMICAL ENGINEERING SCIENCE, 2010, 65 (05) :1875-1886