External fixation of the lower extremities: Biomechanical perspective and recent innovations

被引:41
作者
Bliven, Emily K. [1 ]
Greinwald, Markus [1 ]
Hackl, Simon [1 ]
Augat, Peter [1 ,2 ]
机构
[1] Trauma Ctr Murnau, Inst Biomech, Murnau, Germany
[2] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2019年 / 50卷
关键词
Biomechanics; External fixation; History; Hexapod; Stiffness; Fracture fixation; Deformity correction; Lower extremities; Review; LOCKING COMPRESSION PLATE; DISTAL TIBIAL FRACTURES; SPATIAL FRAME; HEXAPOD ROBOT; STIFFNESS; DISTRACTION; EXPERIENCE; DEVICES; REDUCTION; DEFORMITY;
D O I
10.1016/j.injury.2019.03.041
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The concept of supporting fractured long bones externally with mechanical fixation has been evidentially applied for over 2000 years, and since been expanded on in the mid-19th century by percutaneous bone fixation. Surgical techniques, external fixator systems, and materials have made continued progress since. The benefits of traditional external fixation have been enhanced in recent years with the introduction of hexapod-style fixators, innovative configurations, and pin modifications, among other things. It is generally agreed upon that biomechanical testing of advancements in external fixation must be inclusive of transverse or torsional loading to simulate construct behaviour in realistic scenarios. Biomechanical studies indicate that hexapod-style fixators show comparable axial stiffness to Ilizarov-style systems and improved performance under torsional and transverse forces. The addition of configuration elements to fixators, inclusion of certain carbon fibre chemical compositions, and techniques intended to augment ring thickness have also been investigated, in hopes of increasing construct stiffness under loading. Novel external fixators attempt to broaden their applications by rethinking bone mounting mechanisms and either expanding on or simplifying the implementation of 3D bone segment transport for corrective osteotomy. Older and seemingly unconventional fixation techniques are being rediscovered and evolved further in order to increase patient comfort by improving everyday usability. The development of new pin coatings can potentially enhance the pin-bone interface while lowering infection rates typically expected at thicker soft tissue envelopes. Although complication, malunion, and nonunion rates have decreased over the past 50 years, the clinical results of external fixation today can still be optimized. Unsatisfactory healing in the lower extremities has especially been reported at locations such as the distal tibia; however, advancements such as osteoinductive growth hormone treatment may provide improved results. With the current progression of technology and digitization, it is only a matter of time before 'smart', partly-autonomous external fixation systems enter the market. This review article will provide a versatile overview of biomechanically proven fixator configurations and some carefully selected innovative systems and techniques that have emerged or been established in the past two decades. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S10 / S17
页数:8
相关论文
共 76 条
  • [1] Factors affecting the fracture healing in treatment of tibial shaft fractures with circular external fixator
    Alemdaroglu, Kadir Bahadir
    Tiftikci, Ugur
    Iltar, Serkan
    Aydogan, Nevres Huerriyet
    Kara, Talip
    Atlihan, Dogan
    Atesalp, A. Sabri
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (11): : 1151 - 1156
  • [2] Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness
    Ang, B. F. H.
    Chen, J. Y.
    Yew, A. K. S.
    Chua, S. K.
    Chou, S. M.
    Chia, S. L.
    Koh, J. S. B.
    Howe, T. S.
    [J]. BONE & JOINT RESEARCH, 2017, 6 (04): : 216 - 223
  • [3] Early outcome of hybrid external fixation for fracture of the distal tibia
    Anglen, JO
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (02) : 92 - 97
  • [4] The effect of transfixion wire number and spacing between two levels of fixation on the stiffness of proximal tibial external fixation
    Antoci, V
    Roberts, CS
    Antoci, V
    Voor, MJ
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) : 180 - 186
  • [5] Shear movement at the fracture site delays healing in a diaphyseal fracture model
    Augat, P
    Burger, J
    Schorlemmer, S
    Henke, T
    Peraus, M
    Claes, L
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (06) : 1011 - 1017
  • [6] A retrospective analysis of comminuted intra-articular fractures of the tibial plafond: Open reduction and internal fixation versus external Ilizarov fixation
    Bacon, Stacy
    Smith, Wade R.
    Morgan, Steven J.
    Hasenboehler, Erik
    Philips, Giby
    Williams, Allison
    Ziran, Bruce H.
    Stahel, Philip F.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (02): : 196 - 202
  • [7] The stiffness characteristics of hybrid Ilizarov fixators
    Baran, Onder
    Havitcioglu, Hasan
    Tatari, Hasan
    Cecen, Berivan
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (14) : 2960 - 2963
  • [8] BEHRENS F, 1989, CLIN ORTHOP RELAT R, P15
  • [9] BEHRENS F, 1989, CLIN ORTHOP RELAT R, P5
  • [10] EXTERNAL FIXATION OF THE TIBIA - BASIC CONCEPTS AND PROSPECTIVE EVALUATION
    BEHRENS, F
    SEARLS, K
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (02): : 246 - 254