Indoor leakage test for safety of R-290 split type room air conditioner

被引:51
作者
Li, Tingxun [1 ]
机构
[1] Sun Yat Sen Univ, Sch Engn, Guangzhou 510275, Guangdong, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2014年 / 40卷
关键词
R-290; Propane; Room air conditioner; Leakage; Safety;
D O I
10.1016/j.ijrefrig.2013.11.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
The selection of alternative refrigerants for the room air conditioner (RAC) industry has, in recent years, been a significant challenge. According to the literature, flammable refrigerants may be one of the potential options. In particular, R-290 (propane) has a major possibility to be the chosen working fluid for the next generation of RACs because of its environmental and unique thermo-physical properties. However, its use is hindered by its flammability and the resulting concerns on safety. In this paper, the safety implications of using R-290 are examined through evaluating the effects of certain variables upon the concentrations of leaked refrigerant into a room. R-290 is leaked under different scenarios and its distributions inside room are measured. The results are interpreted with respect to the requirements of RAC safety standards, where it is found that the requirements may need more detailed verifying for wall type RAC. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:380 / 389
页数:10
相关论文
共 10 条
[1]  
[Anonymous], 2012, 470632 GB STAND ADM
[2]   THE BUILDUP OF CONCENTRATION WITHIN A SINGLE ENCLOSED VOLUME FOLLOWING A RELEASE OF NATURAL-GAS [J].
CLEAVER, RP ;
MARSHALL, MR ;
LINDEN, PF .
JOURNAL OF HAZARDOUS MATERIALS, 1994, 36 (03) :209-226
[3]   Appraising the flammability hazards of hydrocarbon refrigerants using quantitative risk assessment model. Part II. Model evaluation and analysis [J].
Colbourne, D ;
Suen, KO .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (07) :784-793
[4]   Equipment design and installation features to disperse refrigerant releases in rooms - part I: experiments and analysis [J].
Colbourne, D ;
Suen, KO .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (06) :667-673
[5]  
Executive Committee of the Multilateral Fund for the Implementation of the Montreal Protocol, 2011, PROJ PROP CHIN UNEP, P12
[6]  
Jabbour T., 2002, 5 IIR G LOR C NAT WO
[7]  
Jabbour T., 2004, ANAL IEC REQUIREMENT
[8]  
Kataoka O., 1999, SE991902 ASHRAE
[9]  
Kataoka O., 2000, INT REFR AIR COND C, P383
[10]  
Liang Jierong, 2012, CRYO SUPERCOND, V39, P42