摘要
In this paper, a portable electrochemical system for the on-site detection of heavy metals (HMs) in farmland soil is developed, characterized, and evaluated. The system has a three-electrode configuration and includes a signal acquisition and processing device and a computer, which integrates a microcontroller-based potentiostat to implement square-wave anodic stripping voltammetry at a bismuth-film-modified glassy carbon electrode. In addition, three analysis methods, namely, the standard addition method, the bivariate regression model, and double-stripping voltammetry, were integrated into this system for the on-site detection of HMs to meet different analysis requirements. One unique characteristic of the system is its custom software, which enables calculations based on all three analysis methods. Moreover, stripping peak currents and background currents can be identified and acquired automatically by two of the developed algorithms. The system was assessed by applying it to detect Pb(II) and Cd(II) in an acetate buffer solution and acetic acid soil extracts. The interference of Cu(II) can be inhibited by adding 0.1-mM ferrocyanide to the real sample exacts by complexation. The results indicate that the system was sensitive, effective, and reliable and has broad application prospects in the field of on-site analysis. In addition, the system can be used by non-specialist personnel.
引用
收藏
页码:5645 / 5655
页数:11
相关论文
共 34 条
  • [1] Akoto O, 2008, INT J ENVIRON RES, V2, P359
  • [2] Recent Trends in Macro-, Micro-, and Nanomaterial-Based Tools and Strategies for Heavy-Metal Detection
    Aragay, Gemma
    Pons, Josefina
    Merkoci, Arben
    [J]. CHEMICAL REVIEWS, 2011, 111 (05) : 3433 - 3458
  • [3] Development of a portable electroanalytical system for the stripping voltammetry of metals: Determination of copper in acetic acid soil extracts
    Beni, V
    Ogurtsov, VI
    Bakunin, NV
    Arrigan, DWM
    Hill, M
    [J]. ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) : 190 - 200
  • [4] Bernard A, 2008, INDIAN J MED RES, V128, P557
  • [5] Determination of Lead and Cadmium in Sea- and Freshwater by Anodic Stripping Voltammetry with a Vibrating Bismuth Electrode
    Bi, Zhaoshun
    Chapman, Conrad S.
    Salauen, Pascal
    van den Berg, Constant M. G.
    [J]. ELECTROANALYSIS, 2010, 22 (24) : 2897 - 2907
  • [6] Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection-anodic stripping voltammetry
    Chaiyo, Sudkate
    Chailapakul, Orawon
    Siangproh, Weena
    [J]. ANALYTICA CHIMICA ACTA, 2014, 852 : 55 - 62
  • [7] Experimental data from a trace metal sensor combining surface plasmon resonance with anodic stripping voltammetry
    Chinowsky, TM
    Saban, SB
    Yee, SS
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) : 37 - 43
  • [8] Voltammetric in situ measurements of heavy metals in soil using a portable electrochemical instrument
    Christidis, K.
    Robertson, P.
    Gow, K.
    Pollard, P.
    [J]. MEASUREMENT, 2007, 40 (9-10) : 960 - 967
  • [9] Crowley K, 2002, ELECTROANAL, V14, P1077, DOI 10.1002/1521-4109(200208)14:15/16<1077::AID-ELAN1077>3.0.CO
  • [10] 2-3