Optical Design of an Integrated Paschen-Runge Spectrometer by Using a Multigrating Structure

被引:1
作者
Xia, Guo [1 ,2 ,3 ]
Zhang, Long [1 ,2 ,3 ]
Feng, Zhiwei [1 ,2 ,3 ]
Shi, Wenjie [1 ,2 ,3 ]
Gao, Lin [1 ,2 ,3 ]
Li, Yanduo [1 ,2 ,3 ]
机构
[1] Hefei Univ Technol, Acad Photoelect Technol, Key Lab Special Display Technol Minist Educ, Natl Engn Lab Special Display Technol,Natl Key Lab, Hefei 230009, Peoples R China
[2] Hefei Univ Technol, Sch Instrument Sci & Optoelect Engn, Hefei 230009, Peoples R China
[3] Hefei Univ Technol, Anhui Prov Key Lab Measuring Theory & Precis Instr, Hefei 230009, Peoples R China
关键词
Paschen-Runge spectrometer; optical design; multigrating; SPECTRAL RESOLUTION;
D O I
10.3390/photonics9120920
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An integrated direct-reading spectrometer scheme using seven concave gratings is proposed. At present, the optical design simulation has been completed, and the subsequent physical design may be carried out according to the simulation results. Ray-tracing software (Zemax) is used to divide the spectrum on the grating into seven bands, and an area array detector is used to receive the spectral signals simultaneously, which reduces the volume of the spectrometer and improves the spectral consistency. Using this method, a spectrometer covering 230-440 nm is designed, and the spectral resolution of the center wavelength corresponding to the seven grating windows of 230-260 nm, 260-290 nm, 290-320 nm, 320-350 nm, 350-380 nm, 380-410 nm, and 410-440 nm can reach 0.0974 nm, 0.0652 nm, 0.0361 nm, 0.0157 nm, 0.0838 nm, 0.0872 nm, and 0.1471 nm.
引用
收藏
页数:9
相关论文
共 21 条
[1]  
Astronomical & Scientific Camera, SCI CAM
[2]   Densely folded spectral images of a CCD spectrometer working in the full 200-1000 nm wavelength range with high resolution [J].
Chen, YR ;
Sun, B ;
Han, T ;
Kong, YF ;
Xu, CH ;
Zhou, P ;
Li, XF ;
Wang, SY ;
Zheng, YX ;
Chen, LY .
OPTICS EXPRESS, 2005, 13 (25) :10049-10054
[3]  
Everett M., 2021, Translational Biophotonics, V3, pe202000012, DOI 10.1002/tbio.202000012
[4]   The optical system design of broadband infrared imaging spectrometer [J].
Fu Yan-peng ;
Wang Hai-yang ;
Jia Xing-rui ;
Ming Jing-qian ;
Zheng Wei-jian ;
Jin Ning ;
Wang Xing .
INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES VII, 2020, 11559
[5]   Method for evaluating spectral resolution based on a single-lens spectrometer [J].
He, Peidong ;
Yuan, Yan ;
Lv, Qunbo ;
Bin Xiangli .
APPLIED OPTICS, 2021, 60 (25) :7834-7843
[6]   Ultrahigh-resolution spectrometer based on 19 integrated gratings [J].
Jiang, An-Qing ;
Zang, Kai-Yan ;
Tu, Hua-Tian ;
Chen, Jian-Ke ;
Lu, Wei-Jie ;
Yoshie, Osamu ;
Wang, Xiao-Ping ;
Xiang, Xiao-Dong ;
Lee, Young-Pak ;
Chen, Bing ;
Zheng, Yu-Xiang ;
Wang, Song-You ;
Zhao, Hai-Bin ;
Yang, Yue-Mei ;
Chen, Liang-Yao .
SCIENTIFIC REPORTS, 2019, 9 (1)
[7]   Swept Source OCT beyond the Coherence Length Limit [J].
Kolokoltsev O. ;
Gomez-Arista I. ;
Trevino-Palacios C.G. ;
Qureshi N. ;
Mejia-Uriarte E.V. .
IEEE Journal of Selected Topics in Quantum Electronics, 2016, 22 (03) :222-227
[8]   High-resolution continuum-source electrothermal atomic absorption spectrometer for simultaneous multi-element determination in the spectral range of 190-780 nm [J].
Labusov, V. A. ;
Boldova, S. S. ;
Selunin, D. O. ;
Semenov, Z. V. ;
Vashchenko, P. V. ;
Babin, S. A. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (05) :1005-1010
[9]   Broadband astigmatism-corrected Czerny-Turner spectrometer [J].
Lee, Kye-Sung ;
Thompson, Kevin P. ;
Rolland, Jannick P. .
OPTICS EXPRESS, 2010, 18 (22) :23378-23384
[10]   In Vivo Imaging of Retinal and Choroidal Morphology and Vascular Plexuses of Vertebrates Using Swept-Source Optical Coherence Tomography [J].
Meleppat, Ratheesh K. ;
Fortenbach, Christopher R. ;
Jian, Yifan ;
Martinez, Esteban Soto ;
Wagner, Karen ;
Modjtahedi, Bobeck S. ;
Motta, Monica J. ;
Ramamurthy, Deepa L. ;
Schwab, Ivan R. ;
Zawadzki, Robert J. .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (08)