Comprehensive analysis on thermal and daylighting performance of glazing and shading designs on office building envelope in cooling-dominant climates

被引:110
作者
Huang, Yu [1 ]
Niu, Jian-lei [1 ]
Chung, Tse-ming [1 ]
机构
[1] Hong Kong Polytech Univ, Fac Construct & Environm, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Shading design; Low-e glazing; Building envelope; Energy-efficient design; Solar heat gain; HIGHRISE RESIDENTIAL BUILDINGS; ENERGY-CONSUMPTION; TYPICAL OFFICE; WINDOW BLINDS; HEAT-TRANSFER; SOLAR-CELLS; SIMULATION; COMFORT; SAVINGS; GLASS;
D O I
10.1016/j.apenergy.2014.07.100
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Conducting energy-efficient designs on building window can be a solution to relieving the pressure caused by growing building energy consumption. In this paper, a series of simulation studies were carried out to evaluate the performance of several popular energy-efficient window designs in cooling-dominant climates. Both thermal and daylighting performance were considered during the analysis. Results indicate that among all designs studied, low-e glazing achieves a best performance, while double-layer glazing performs the worst. Energy-efficient designs on the east and west orientations are the most cost-effective in cooling-dominant climates. As latitude rises, the performance of window designs on the south orientation is getting better. It is also discovered that only in area very close to equator performance of north facing window designs is satisfactory. Furthermore, as the reflectivity of blind louver decreases, both thermal and daylighting performances drop. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:215 / 228
页数:14
相关论文
共 62 条
[1]   Conventional fixed shading devices in comparison to an electrochromic glazing system in hot, dry climate [J].
Aldawoud, Abdelsalam .
ENERGY AND BUILDINGS, 2013, 59 :104-110
[2]  
AlHomoud MS, 1997, INT J ENERG RES, V21, P941, DOI 10.1002/(SICI)1099-114X(199708)21:10<941::AID-ER302>3.0.CO
[3]  
2-Y
[4]   Determination of optimum thickness of double-glazed windows for the climatic regions of Turkey [J].
Arici, Muesluem ;
Karabay, Hasan .
ENERGY AND BUILDINGS, 2010, 42 (10) :1773-1778
[5]   Code compliance of fully glazed tall office buildings in hot climate [J].
Assem, E. O. ;
Al-Mumin, A. A. .
ENERGY AND BUILDINGS, 2010, 42 (07) :1100-1105
[6]   A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device [J].
Athienitis, AK ;
Tzempelikos, A .
SOLAR ENERGY, 2002, 72 (04) :271-281
[7]   Determination of optimum air-layer thickness in double-pane windows [J].
Aydin, O .
ENERGY AND BUILDINGS, 2000, 32 (03) :303-308
[8]   Conjugate heat transfer analysis of double pane windows [J].
Aydin, O .
BUILDING AND ENVIRONMENT, 2006, 41 (02) :109-116
[9]   Global energy savings in offices buildings by the use of daylighting [J].
Bodart, M ;
De Herde, A .
ENERGY AND BUILDINGS, 2002, 34 (05) :421-429
[10]   Energy performance of windows in high-rise residential buildings in Hong Kong [J].
Bojic, M ;
Yik, F ;
Sat, P .
ENERGY AND BUILDINGS, 2002, 34 (01) :71-82