Upgrade of the CMS muon trigger system in the barrel region

被引:2
|
作者
Rabady, Dinyar [1 ]
Ero, Janos [1 ]
Flouris, Giannis [2 ]
Fulcher, Jonathan [3 ]
Loukas, Nikitas [2 ]
Paradas, Evangelos [2 ]
Reis, Thomas [3 ]
Sakulin, Hannes [3 ]
Wulz, Claudia-Elisabeth [3 ]
机构
[1] Inst High Energy Phys Vienna HEPHY, Nikolsdorfer Gasse 18, A-1050 Vienna, Austria
[2] Univ Ioannina, GR-45110 Ioannina, Greece
[3] CERN, CH-1211 Geneva 23, Switzerland
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2017年 / 845卷
关键词
CERN; CMS; Trigger; Muon; Electronics;
D O I
10.1016/j.nima.2016.05.071
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To maintain the excellent performance shown during the LHC's Run-1 the Level-1 Trigger of the Compact Muon Solenoid experiment underwent a significant upgrade. One part of this upgrade is the re-organization of the muon trigger path from a subsystem-centric view in which hits in the drift tubes (DT), the cathode strip chambers (CSC), and the resistive plate chambers (RPC) were treated separately in dedicated track-finding systems to one in which complementary detector systems for a given region (barrel, overlap, and endcap) are merged at the track-finding level. This fundamental restructuring of the muon trigger system required the development of a system to receive track candidates from the track-finding layer, remove potential duplicate tracks, and forward the best candidates to the global decision layer. An overview will be given of the new track-finder system for the barrel region, the Barrel Muon Track Finder (BMTF), as well as the cancel-out and sorting layer: the upgraded Global Muon Trigger (mu GMT). Both the BMTF and mu GMT have been implemented in a Xilinx Virtex-7 card utilizing the microTCA architecture. While the BMTF improves on the proven and well-tested algorithms used in the Drift Tube Track Finder during Run-1, the mu GMT is an almost complete re-development due to the re-organization of the underlying systems from track-finders for a specific detector to regional track finders covering a given area of the whole detector. Additionally the mu GMT calculates a muon's isolation using energy information received from the calorimeter trigger. This information is added to the muon objects forwarded to the global decision layer, the so-called Global Trigger. (C) 2016 The Authors. Published by Elsevier B.V.
引用
收藏
页码:616 / 620
页数:5
相关论文
共 50 条
  • [31] Sorting devices for the CSC muon trigger system at CMS
    Matveev, M
    Padley, P
    PROCEEDINGS OF THE SEVENTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2001, 2001 (05): : 375 - 378
  • [32] The drift velocity monitoring system of the CMS barrel muon chambers
    Altenhoefer, Georg
    Hebbeker, Thomas
    Heidemann, Carsten
    Reithler, Hans
    Sonnenschein, Lars
    Teyssier, Daniel
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 1 - 8
  • [33] The PHENIX Muon trigger upgrade
    Lajoie, John
    PROCEEDINGS OF THE 17TH INTERNATIONAL SPIN PHYSICS SYMPOSIUM, 2007, 915 : 490 - 493
  • [34] A Proposal for the Upgrade of the Muon Drift Tubes Trigger for the CMS Experiment at the HL-LHC
    Pozzobon, Nicola
    Zotto, Pierluigi
    Montecassiano, Fabio
    CONNECTING THE DOTS 2016, 2016, 127
  • [35] Upgrade of the CMS muon system with triple-GEM detectors
    Abbaneo, D.
    Abbas, M.
    Abbrescia, M.
    Abdelalim, A. A.
    Akl, M. Abi
    Ahmed, W.
    Ahmed, W.
    Altieri, P.
    Aly, R.
    Ashfaq, A.
    Aspell, P.
    Assran, Y.
    Awan, I.
    Bally, S.
    Ban, Y.
    Banerjee, S.
    Barria, P.
    Benussi, L.
    Bhopatkar, V.
    Bianco, S.
    Bos, J.
    Bouhali, O.
    Braibant, S.
    Buontempo, S.
    Cai, J.
    Calabria, C.
    Caputo, C.
    Cassese, F.
    Castaneda, A.
    Cauwenbergh, S.
    Cavallo, F. R.
    Celik, A.
    Choi, M.
    Choi, K.
    Choi, S.
    Christiansen, J.
    Cimmino, A.
    Colafranceschi, S.
    Colaleo, A.
    Garcia, A. Conde
    Dabrowski, M. M.
    De Lentdecker, G.
    De Oliveira, R.
    de Robertis, G.
    Dildick, S.
    Dorney, B.
    Elmetenawee, W.
    Fabrice, G.
    Ferry, S.
    Giacomelli, P.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [36] Upgrade of the CMS Muon system with Triple-GEM detectors
    Simone, Federica Maria
    Venditti, Rosamaria
    Soldani, Elisabetta
    2019 IEEE 8TH INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES (IWASI), 2019, : 42 - 47
  • [37] Upgrade of the CMS muon system with Triple-GEM detectors
    Caputo, C.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2015, 38 (01):
  • [38] Trigger primitive generation algorithm in the CMS barrel muon chambers during HL-LHC
    Trevisani, N.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (12):
  • [39] A New Interface Board for the Level-1 Muon Barrel Trigger Upgrade of the ATLAS Experiment
    Izzo, V.
    Aloisio, A.
    Giordano, R.
    Perrella, S.
    Vari, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (07) : 1028 - 1035
  • [40] RPC system in the CMS Level-1 Muon Trigger
    Samalan, A.
    Tytgat, M.
    Zaganidis, N.
    Alves, G. A.
    Marujo, F.
    Da Silva De Araujo, F. Torres
    Da Costa, E. M.
    De Jesus Damiao, D.
    Nogima, H.
    Santoro, A.
    Fonseca De Souza, S.
    Aleksandrov, A.
    Hadjiiska, R.
    Iaydjiev, P.
    Rodozov, M.
    Shopova, M.
    Sultanov, G.
    Bonchev, M.
    Dimitrov, A.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Petrov, A.
    Qian, S. J.
    Cao, P.
    Kou, H.
    Liu, Z.
    Song, J.
    Zhao, J.
    Bernal, C.
    Cabrera, A.
    Fraga, J.
    Sarkar, A.
    Elsayed, S.
    Assran, Y.
    El Sawy, M.
    Mahmoud, M. A.
    Mohammed, Y.
    Combaret, C.
    Gouzevitch, M.
    Grenier, G.
    Laktineh, I
    Mirabito, L.
    Shchablo, K.
    Bagaturia, I
    Lomidze, D.
    Lomidze, I
    Bhatnagar, V
    Gupta, R.
    Kumari, P.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (10):