APPLICATION OF THE CHIMNEY CAP AS A METHOD OF IMPROVING THE EFFECTIVENESS OF NATURAL VENTILATION IN BUILDINGS

被引:2
|
作者
Antczak-Jarzabska, Romana [1 ]
Niedostatkiewicz, Maciej [1 ]
机构
[1] Gdansk Univ Technol, 11-12 Gabriela Narutowicza St, PL-80233 Gdansk, Poland
关键词
natural ventilation; chimney cap; ACH; wind effect; effectiveness;
D O I
10.2478/pomr-2020-0058
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Adequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the air inside a building fresh. A prediction of the performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long-term cost savings. The worst time in terms of the efficiency of natural ventilation is the spring-autumn transition period [7]. In order to improve the efficiency of natural ventilation, chimney caps are used, among others. They are designed to improve the chimney effect described in colloquial language as a chimney draft. The chimney effect is a physical phenomenon of the formation of a spontaneous flow of a warmer gas, e.g. air, from the bottom up in stem channels [12]. The article analyses the influence of the chimney cowl on the improvement of the chimney effect in an apartment of a multi-family building with natural ventilation. Long-term tests of the chimney draft were carried out for the case without and with a chimney cap. The paper presents the results of the performance (air change rate, ACH) of natural ventilation for a building with an inlet gap measured for the transitional season (between the heating and the summer season). The measurements were performed during a windy period.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [31] Introducing a new estimation method for calculating the effect of natural ventilation control in high rise buildings with buoyancy driven ventilation study on the performance evaluation of natural ventilation control in of office buildings (Part 2)
    Shimonosono K.
    Kohri K.
    Ishino H.
    1600, Architectural Institute of Japan (85): : 331 - 339
  • [32] Analysis of thermal mass in natural ventilation buildings
    Zhou Jun-li
    Zhang Guo-qiang
    Wu Jia-sheng
    Li Yu-guo
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 76 - 80
  • [33] Controlled natural ventilation for energy efficient buildings
    Schulze, Tobias
    Eicker, Ursula
    ENERGY AND BUILDINGS, 2013, 56 : 221 - 232
  • [34] Coupling of thermal mass and natural ventilation in buildings
    Zhou, Junli
    Zhang, Guoqiang
    Lin, Yaolin
    Li, Yuguo
    ENERGY AND BUILDINGS, 2008, 40 (06) : 979 - 986
  • [35] Summer-performance of inclined roof solar chimney for natural ventilation
    Mathur, Jyotirmay
    Mathur, Sanjay
    Anupma
    ENERGY AND BUILDINGS, 2006, 38 (10) : 1156 - 1163
  • [36] An experimental investigation of an inclined passive wall solar chimney for natural ventilation
    Khanal, Rakesh
    Lei, Chengwang
    SOLAR ENERGY, 2014, 107 : 461 - 474
  • [37] A scaling investigation of the laminar convective flow in a solar chimney for natural ventilation
    Khanal, Rakesh
    Lei, Chengwang
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2014, 45 : 98 - 108
  • [38] Indoor conditions in silesian buildings with natural ventilation
    Nantka, Marian B.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (06) : 571 - 582
  • [39] Natural ventilation as a strategy for thermal comfort in buildings
    de Souza, Henor Artur
    Rodrigues, Luciano Souza
    REM-REVISTA ESCOLA DE MINAS, 2012, 65 (02) : 189 - 194
  • [40] Numerical study on natural ventilation performance of combined solar chimney with blinds
    Sun R.
    Lei Y.
    Song C.
    Jing S.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (10): : 452 - 457