Status of the Brookhaven National Laboratory high current electron beam ion source test stand

被引:6
|
作者
Beebe, E
Alessi, J
Bellavia, S
Hershcovitch, A
Kponou, A
Lockey, R
Pikin, A
Prelec, K
Stein, P
Kuznetsov, G
Tiunov, M
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
[2] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2000年 / 71卷 / 02期
关键词
D O I
10.1063/1.1150324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As part of a new, compact heavy ion injector for the AGS/RHIC complex at Brookhaven National Laboratory we are developing an electron beam ion source (EBIS) that would satisfy present and future requirements. Such a source should be capable of producing intensities of, e.g., Au35+ ions of about 3x10(9) particles/pulse or U45+ of about 2x10(9) particles/pulse. To achieve this, the required e-beam intensity is 10 A, at a pulse length of 100 ms. An EBIS test stand has been constructed, designed for the full electron beam power and having close to 1/2 of the trap length of an EBIS for RHIC. Initial electron beam tests have resulted in a 50 mu s, 13 A electron beam. Ion production and extraction has been shown with a 3.1 A, 50 ms electron beam, achieving an ion yield of 19 nC/pulse (neutralization degree of 61%); fast extraction trials have yielded extracted ion pulses of 1 mA peak current and 18 mu s at FWHM. Details of the test stand construction, results of the electron beam studies, and properties of the extracted ion pulse are presented. (C) 2000 American Institute of Physics. [S0034-6748(00)60302-7].
引用
收藏
页码:893 / 895
页数:3
相关论文
共 50 条
  • [1] Brookhaven national laboratory electron beam test stand
    Pikin, A
    Alessi, J
    Beebe, E
    Kponou, A
    Prelec, K
    Snydstrup, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 697 - 699
  • [2] Brookhaven National Laboratory electron beam test stand
    Pikin, A.
    Alessi, J.
    Beebe, E.
    Kponou, A.
    Prelec, K.
    Snydstrup, L.
    Review of Scientific Instruments, 1998, 69 (2 pt 2):
  • [3] The Brookhaven National Laboratory electron beam ion source for RHIC
    Alessi, J. G.
    Barton, D.
    Beebe, E.
    Bellavia, S.
    Gould, O.
    Kponou, A.
    Lambiase, R.
    Lockey, R.
    McNerney, A.
    Mapes, M.
    Marneris, Y.
    Okamura, M.
    Phillips, D.
    Pikin, A. I.
    Raparia, D.
    Ritter, J.
    Snydstrup, L.
    Theisen, C.
    Wilinski, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [4] Experimental results from the Brookhaven National Laboratory test electron beam ion source
    Beebe, E
    Alessi, J
    Hershcovitch, A
    Kponou, A
    Pikin, A
    Prelec, K
    Stein, P
    Schmieder, RW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 640 - 642
  • [5] Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory
    Kondrashev, S.
    Beebe, E.
    Coe, B.
    Ikeda, S.
    Kanesue, T.
    Landon, G.
    Okamura, M.
    Raparia, D.
    Ritter, J.
    Rodowicz, T.
    Schoepfer, B.
    Vorbach, R.
    JOURNAL OF INSTRUMENTATION, 2025, 20 (02):
  • [6] Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source
    Kondo, K.
    Yamamoto, T.
    Sekine, M.
    Okamura, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [7] Multiple species beam production on laser ion source for electron beam ion source in Brookhaven National Laboratory
    Sekine, M.
    Ikeda, S.
    Hayashizaki, N.
    Kanesue, T.
    Okamura, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [8] Electron and Ion Beam Simulations for the BNL ExtendedEBIS at Brookhaven National Laboratory
    Ikeda, S.
    Beebe, E.
    Okamura, M.
    Pikin, A.
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [9] NEUTRAL BEAM TEST FACILITY AT BROOKHAVEN NATIONAL LABORATORY
    MCKENZIEWILSON, RB
    VELIGDAN, JT
    ACQUISITION, TRACKING, AND POINTING III, 1989, 1111 : 160 - 169
  • [10] Laser ion source activities at Brookhaven National Laboratory
    Kanesue, Takeshi
    Okamura, Masahiro
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2015, 170 (04): : 347 - 354