Seismic and Energy Retrofit of Apartment Buildings through Autoclaved Aerated Concrete (AAC) Blocks Infill Walls

被引:28
作者
Artino, Antonio [1 ]
Evola, Gianpiero [2 ]
Margani, Giuseppe [3 ]
Marino, Edoardo Michele [3 ]
机构
[1] Via Nino Papaldo 11, I-95030 Pedara, Italy
[2] Univ Catania, Dept Elect Elect & Comp Engn DIEEI, Viale A Doria 6, I-95125 Catania, Italy
[3] Univ Catania, Dept Civil Engn & Architecture DICAr, Via S Sofia 64, I-95123 Catania, Italy
关键词
integrated design; sustainable building renovation; existing RC buildings; seismic safety; energy efficiency; FRAMES; MODEL;
D O I
10.3390/su11143939
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
All around the world, a huge amount of buildings have been built before the enforcement of specific codes for seismic resistance and energy efficiency. Particularly in Italy, over 74% of residential buildings were constructed before 1980, when only 25% of the territory was classified as seismic, and nearly 86% were built before 1991, when the first restrictive regulation on energy efficiency was issued. This means that most buildings need both seismic and energy renovation actions to improve their sustainability level. The proposed combined retrofit strategy for reinforced concrete framed buildings is based on the replacement of the external layer of double-leaf infill walls, made of hollow bricks, with high-performing AAC blocks: this solution can be implemented by operating mainly from the outside of the building, thus reducing occupants' disruption during retrofitting. The generally neglected structural contribution of masonry infill panels is here considered using a recently developed macro-element modeling approach. The results suggest that, from a structural viewpoint, the proposed intervention involves the highest improvement at the damage limitation limit state, while lower upgrades are recorded at life safety limit state and near-collapse limit state. In regards to the energy issues, the energy demand can be reduced by 10% and 4% for heating and cooling, respectively, just by replacing the outer layer of blocks; further savings can be achieved through the application of a supplementary insulation layer.
引用
收藏
页数:21
相关论文
共 37 条
[1]  
[Anonymous], 1993, Gazzetta Ufficiale della Repubblica Italiana - Agenzia Italiana del Farmaco (AIFA)
[2]  
[Anonymous], 2004, 19981 EN, Vfirst
[3]  
[Anonymous], 2011, BUILD PERFORM I EURO
[4]  
BOURNAS D, 2018, INNOVATIVE MAT SEISM
[5]   Concurrent seismic and energy retrofitting of RC and masonry building envelopes using inorganic textile-based composites combined with insulation materials: A new concept [J].
Bournas, Dionysios A. .
COMPOSITES PART B-ENGINEERING, 2018, 148 :166-179
[6]   A macro-element modelling approach of Infilled Frame Structures [J].
Calio, Ivo ;
Panto, Bartolomeo .
COMPUTERS & STRUCTURES, 2014, 143 :91-107
[7]   A new discrete element model for the evaluation of the seismic behaviour of unreinforced masonry buildings [J].
Calio, Ivo ;
Marletta, Massimo ;
Panto, Bartolomeo .
ENGINEERING STRUCTURES, 2012, 40 :327-338
[8]  
Christopoulos C., 2006, Principles of Passive Supplemental Damping and Seismic Isolation
[9]   From the Efficiency of Nature to Parametric Design. A Holistic Approach for Sustainable Building Renovation in Seismic Regions [J].
D'Urso, Sebastiano ;
Cicero, Bruno .
SUSTAINABILITY, 2019, 11 (05)
[10]   Strength and stiffness reduction factors for infilled frames with openings [J].
Decanini, Luis D. ;
Liberatore, Laura ;
Mollaioli, Fabrizio .
EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2014, 13 (03) :437-454