Adapting a geared domestic refrigerative dehumidifier for low-temperature operation

被引:6
|
作者
Lowrey, S. [1 ]
Carrington, G. [1 ]
Sun, Z. [1 ]
机构
[1] Univ Otago, Dept Phys, Dunedin, New Zealand
关键词
Geared dehumidifier; Frosting; Air conditioning; Dehumidification; PERFORMANCE; ENERGY;
D O I
10.1016/j.ijrefrig.2013.09.043
中图分类号
O414.1 [热力学];
学科分类号
摘要
It has been established that geared domestic refrigerative dehumidifiers behave poorly when operated in low-temperature household environments where frosting of the evaporator occurs. The hot-side temperature drop introduced by the air-side evaporator economiser is a primary factor in the poor performance of the system if the economiser is too efficient. In this paper, methods for pushing the geared dehumidifier frosting limit to lower ambient temperatures are explored numerically and implemented experimentally with a test system. The methods tested here include a modified refrigerant evaporator, control of the economiser's thermal effectiveness and an integrated approach which includes both methods in conjunction with variable air flow. Results presented in this paper demonstrate operation of a geared domestic dehumidifier with improved dehumidification capacity over the conventional system by around 10% at a moist air condition of 15.4 degrees C, 70% relative humidity, without evaporator frosting. (C) 2014 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 50 条
  • [21] Active Fiber Hydrogen Sensors for Low-Temperature Operation
    Chen, Tong
    Buric, Michael P.
    Chen, Kevin P.
    Swinehart, Philip R.
    Maklad, Mokhtar
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 934 - +
  • [22] MEASUREMENT OF THE TEMPERATURE INSIDE THE ROTOR OF THE AIRFUGE AND ITS OPERATION AT LOW-TEMPERATURE
    KOCH, HJ
    WICHARDT, UP
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1983, 7 (03): : 235 - 241
  • [23] Role of exogenous abscisic acid in adapting of 'Sultana' grapevine to low-temperature stress
    Karimi, Rouhollah
    Ershadi, Ahmad
    ACTA PHYSIOLOGIAE PLANTARUM, 2015, 37 (08)
  • [24] Role of exogenous abscisic acid in adapting of ‘Sultana’ grapevine to low-temperature stress
    Rouhollah Karimi
    Ahmad Ershadi
    Acta Physiologiae Plantarum, 2015, 37
  • [25] LOW-TEMPERATURE CORROSION OF STEELS OF CHIMNEYS IN OPERATION OF BOILERS ON OIL
    STRIKHA, II
    KHOMICH, AS
    THERMAL ENGINEERING, 1979, 26 (12) : 719 - 721
  • [26] The optimalization of the heat pump operation in low-temperature heating systems
    Petrás, D
    Matej, P
    ENERGY FOR BUILDINGS, 2004, : 346 - 351
  • [27] Passive Photovoltaic Cooling: Advances Toward Low-Temperature Operation
    Liu, Junwei
    Zhou, Yifan
    Zhou, Zhihua
    Du, Yahui
    Wang, Cheng
    Yang, Xueqing
    Lin, Zhenjia
    Guo, Zhilin
    Zhao, Jun
    Ye, Long
    Zhang, Haoran
    Yan, Jinyue
    ADVANCED ENERGY MATERIALS, 2024, 14 (02)
  • [28] IMPACT OF LDD STRUCTURES ON THE OPERATION OF SILICON MOSFETS AT LOW-TEMPERATURE
    HAFEZ, IM
    GHIBAUDO, G
    BALESTRA, F
    HAOND, M
    SOLID-STATE ELECTRONICS, 1995, 38 (02) : 419 - 424
  • [29] Low-Temperature Operation of a Bulk HTSC Staggered Array Undulator
    Kii, T.
    Kinjo, R.
    Kimura, N.
    Shibata, M.
    Bakr, M. A.
    Choi, Y. W.
    Omer, M.
    Yoshida, K.
    Ishida, K.
    Komai, T.
    Shimahashi, K.
    Sonobe, T.
    Zen, H.
    Masuda, K.
    Ohgaki, H.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [30] OPTIMIZATION OF THE OPERATION OF A REACTOR FOR THE LOW-TEMPERATURE SYNTHESIS OF ORGANOMETALLIC COMPOUNDS
    DOMRACHEV, GA
    KARNATSEVICH, VL
    ANDREEV, IG
    SHEVELEV, YA
    MENTSOV, BE
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1984, 57 (06): : 1173 - 1176