Adapting a geared domestic refrigerative dehumidifier for low-temperature operation

被引:6
|
作者
Lowrey, S. [1 ]
Carrington, G. [1 ]
Sun, Z. [1 ]
机构
[1] Univ Otago, Dept Phys, Dunedin, New Zealand
关键词
Geared dehumidifier; Frosting; Air conditioning; Dehumidification; PERFORMANCE; ENERGY;
D O I
10.1016/j.ijrefrig.2013.09.043
中图分类号
O414.1 [热力学];
学科分类号
摘要
It has been established that geared domestic refrigerative dehumidifiers behave poorly when operated in low-temperature household environments where frosting of the evaporator occurs. The hot-side temperature drop introduced by the air-side evaporator economiser is a primary factor in the poor performance of the system if the economiser is too efficient. In this paper, methods for pushing the geared dehumidifier frosting limit to lower ambient temperatures are explored numerically and implemented experimentally with a test system. The methods tested here include a modified refrigerant evaporator, control of the economiser's thermal effectiveness and an integrated approach which includes both methods in conjunction with variable air flow. Results presented in this paper demonstrate operation of a geared domestic dehumidifier with improved dehumidification capacity over the conventional system by around 10% at a moist air condition of 15.4 degrees C, 70% relative humidity, without evaporator frosting. (C) 2014 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 50 条
  • [1] Experimental investigation of geared domestic refrigerative dehumidifier performance in New Zealand household climates
    Lowrey, S.
    Carrington, G.
    Sun, Z.
    Cunningham, M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04): : 750 - 756
  • [2] EXPERIMENTAL INVESTIGATION OF GEARED DOMESTIC REFRIGERATIVE DEHUMIDIFIER PERFORMANCE IN NEW ZEALAND HOUSEHOLD CLIMATES
    Lowrey, S.
    Carrington, G.
    Sun, Z.
    Cunningham, M.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 212 - +
  • [3] Fluid flow modulation in a domestic refrigerative dehumidifier with air-side gearing
    Lowrey, S.
    Le Bonniec, G.
    Sun, Z.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 258 - 265
  • [4] Low-temperature drying using a versatile heat pump dehumidifier
    Sosle, V
    Raghavan, GSV
    Kittler, R
    DRYING TECHNOLOGY, 2003, 21 (03) : 539 - 554
  • [5] Development of low-temperature operation SOFC
    Akikusa, J
    Yamada, T
    Adachi, K
    Hoshino, K
    Ishihara, T
    Takika, Y
    SOLID OXIDE FUEL CELLS VII (SOFC VII), 2001, 2001 (16): : 159 - 165
  • [6] Overview of Solutions for the Low-Temperature Operation of Domestic Hot-Water Systems with a Circulation Loop
    Benakopoulos, Theofanis
    Vergo, William
    Tunzi, Michele
    Salenbien, Robbe
    Svendsen, Svend
    ENERGIES, 2021, 14 (11)
  • [7] OPERATION OF UNITS OF LOW-TEMPERATURE CONDENSATION AND SEPARATION
    MILSHTEIN, LM
    SELISHCHEVA, SA
    CHEPKASOV, VM
    BOIKO, SI
    NEFTYANOE KHOZYAISTVO, 1977, (06): : 54 - 56
  • [8] Assessment of the operation of a low-temperature adsorption refrigerator
    Chalaev D.M.
    Aristov Yu.I.
    Thermal Engineering, 2006, 53 (3) : 240 - 244
  • [9] VERY SMALL MOSFETS FOR LOW-TEMPERATURE OPERATION
    GAENSSLEN, FH
    RIDEOUT, VL
    WALKER, EJ
    WALKER, JJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1977, 24 (03) : 218 - 229
  • [10] IMAGING ELECTROMETER CAPABLE OF LOW-TEMPERATURE OPERATION
    MAYNARD, JD
    CARVER, TR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (02): : 190 - 194