Raman process analyzer calibration transfer through analyzer standardization

被引:1
作者
Shaheen, M [1 ]
Manoharan, R [1 ]
机构
[1] Rosemount Analyt Inc, Orrville, OH 44667 USA
来源
OPTICAL ONLINE INDUSTRIAL PROCESS MONITORING | 1999年 / 3859卷
关键词
Raman spectroscopy; process analyzer; calibration transfer; analyzer standardization;
D O I
10.1117/12.372938
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As Raman spectroscopy finds increased utilization for on-line measurement, the issues of analyzer stability and calibration transferability grow in importance. This paper presents a method that allows calibrations developed an one analyzer to be transferred to others located at the same or different sites. This method also allows maintenance of calibrations in a single Raman analyzer overtime even when critical components are altered. Calibration transfer eliminates the need to develop calibrations for different analyzers and upon analyzer repair, saving time and money in calibration model development and maintenance.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [31] Quantitative visualization of photosynthetic pigments in tea leaves based on Raman spectroscopy and calibration model transfer
    Jianjun Zeng
    Wen Ping
    Alireza Sanaeifar
    Xiao Xu
    Wei Luo
    Junjing Sha
    Zhenxiong Huang
    Yifeng Huang
    Xuemei Liu
    Baishao Zhan
    Hailiang Zhang
    Xiaoli Li
    Plant Methods, 17
  • [32] Process analytical technology case study, part III: Calibration monitoring and transfer
    Cogdill R.P.
    Anderson C.A.
    Drennen III J.K.
    AAPS PharmSciTech, 6 (2)
  • [33] Calibration transfer of near infrared spectrometers for the assessment of plasma ethanol precipitation process
    Sun, Zhongyu
    Wang, Jiayue
    Nie, Lei
    Li, Lian
    Cao, Dawei
    Fan, Jiajin
    Wang, Haiyan
    Liu, Ruichen
    Zhang, Yinran
    Zang, Hengchang
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2018, 181 : 64 - 71
  • [34] Process analytical technology case study, part III: Calibration monitoring and transfer
    Cogdill, RP
    Anderson, CA
    Drennen, JK
    AAPS PHARMSCITECH, 2005, 6 (02):
  • [35] Calibration transfer of chemometric models based on process nuclear magnetic resonance spectroscopy
    Gislason, J
    Chan, H
    Sardashti, M
    APPLIED SPECTROSCOPY, 2001, 55 (11) : 1553 - 1560
  • [36] Calibration transfer of a Raman spectroscopic quantification method for the assessment of liquid detergent compositions from at-line laboratory to in-line industrial scale
    Brouckaert, D.
    Uyttersprot, J-S.
    Broeckx, W.
    De Beer, T.
    TALANTA, 2018, 179 : 386 - 392
  • [37] Research on Application of Direct Standardization Algorithm in Near-Infrared Spectrum Calibration Transfer of Acid Value and Peroxide Value of Edible Oil
    Liu Cui-ling
    Li Tian-rui
    Wei Li-na
    Xu Ying-ying
    Wu Jing-zhu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (10) : 3042 - 3050
  • [38] Calibration transfer of a Raman spectroscopic quantification method for the assessment of liquid detergent compositions between two at-line instruments installed at two liquid detergent production plants
    Brouckaert, D.
    Uyttersprot, J. -S.
    Broeckx, W.
    De Beer, T.
    ANALYTICA CHIMICA ACTA, 2017, 984 : 1 - 18
  • [39] Non invasive process probe for inline Raman monitoring through optical inspection glasses
    Braun, Frank
    Schalk, Robert
    Brunner, Jochen
    Eckhardt, Hanns Simon
    Theuer, Michael
    Veith, Ute
    Hennig, Steffen
    Ferstl, Wolfgang
    Methner, Frank-Juergen
    Beuermann, Thomas
    Gretz, Norbert
    Raedle, Matthias
    TM-TECHNISCHES MESSEN, 2016, 83 (10) : 593 - 605
  • [40] Taking NIR Calibrations of Feed Compounds from the Laboratory to the Process: Calibration Transfer between Predispersive and Postdispersive Instruments
    Fernandez-Ahumada, Elvira
    Garrido-Varo, Ana
    Guerrero, Jose E.
    Perez-Marin, Dolores
    Fearn, Tom
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (21) : 10135 - 10141