Raman process analyzer calibration transfer through analyzer standardization

被引:1
|
作者
Shaheen, M [1 ]
Manoharan, R [1 ]
机构
[1] Rosemount Analyt Inc, Orrville, OH 44667 USA
来源
OPTICAL ONLINE INDUSTRIAL PROCESS MONITORING | 1999年 / 3859卷
关键词
Raman spectroscopy; process analyzer; calibration transfer; analyzer standardization;
D O I
10.1117/12.372938
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As Raman spectroscopy finds increased utilization for on-line measurement, the issues of analyzer stability and calibration transferability grow in importance. This paper presents a method that allows calibrations developed an one analyzer to be transferred to others located at the same or different sites. This method also allows maintenance of calibrations in a single Raman analyzer overtime even when critical components are altered. Calibration transfer eliminates the need to develop calibrations for different analyzers and upon analyzer repair, saving time and money in calibration model development and maintenance.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [21] Fundamentals of calibration transfer through Procrustes analysis
    Anderson, CE
    Kalivas, JH
    APPLIED SPECTROSCOPY, 1999, 53 (10) : 1268 - 1276
  • [22] Multichannel Raman gas analyzer: The data acquisition and control system. Measurement improvement with blue laser light
    Papageorgas, PG
    Maroulis, D
    Winter, H
    Karkanis, SA
    Albrecht, H
    Theofanous, NG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2004, 53 (01) : 58 - 66
  • [23] Impact of standardization sample design on Tikhonov regularization variants for spectroscopic calibration maintenance and transfer
    Kunz, Matthew R.
    Ottaway, Joshua
    Kalivas, John H.
    Andries, Erik
    JOURNAL OF CHEMOMETRICS, 2010, 24 (3-4) : 218 - 229
  • [24] Transfer of near-infrared calibration model for determining fiber content in flax: Effects of transfer samples and standardization procedure
    Sohn, Miryeong
    Barton, Franklin E., II
    Himmelsbach, David S.
    APPLIED SPECTROSCOPY, 2007, 61 (04) : 414 - 418
  • [25] Calibration Transfer of a Quantitative Transmission Raman PLS Model: Direct Transfer vs. Global Modeling
    Steinbach, Douglas
    Anderson, Carl A.
    McGeorge, Gary
    Igne, Benoit
    Bondi, Robert W.
    Drennen, James K., III
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2017, 12 (04) : 347 - 356
  • [26] Kinetics of structure II gas hydrate formation for propane and ethane using an in-situ particle size analyzer and a Raman spectrometer
    Al-Otaibi, Faisal
    Clarke, Matthew
    Maini, Brij
    Bishnoi, P. R.
    CHEMICAL ENGINEERING SCIENCE, 2011, 66 (11) : 2468 - 2474
  • [27] Calibration Transfer of a Quantitative Transmission Raman PLS Model: Direct Transfer vs. Global Modeling
    Douglas Steinbach
    Carl A. Anderson
    Gary McGeorge
    Benoit Igne
    Robert W. Bondi
    James K. Drennen
    Journal of Pharmaceutical Innovation, 2017, 12 : 347 - 356
  • [28] Calibration transfer of a Raman spectroscopic quantification method from at-line to in-line assessment of liquid detergent compositions
    Brouckaert, D.
    Uyttersprot, J. -S.
    Broeckx, W.
    De Beer, T.
    ANALYTICA CHIMICA ACTA, 2017, 971 : 14 - 25
  • [29] Assessment of Ten Standardization-Based Calibration Transfer Techniques for Gas Sensors in a Small Data Context
    Muppidathi, Balakumara Vignesh
    Ngoune, Bernard Bobby
    Hallil, Hamida
    Subbiah, Senthilmurugan
    Lebental, Berengere
    IEEE SENSORS JOURNAL, 2024, 24 (23) : 39243 - 39251
  • [30] Quantitative visualization of photosynthetic pigments in tea leaves based on Raman spectroscopy and calibration model transfer
    Zeng, Jianjun
    Ping, Wen
    Sanaeifar, Alireza
    Xu, Xiao
    Luo, Wei
    Sha, Junjing
    Huang, Zhenxiong
    Huang, Yifeng
    Liu, Xuemei
    Zhan, Baishao
    Zhang, Hailiang
    Li, Xiaoli
    PLANT METHODS, 2021, 17 (01)