Comparison of 3-dimensional versus 2-dimensional laparoscopic vision system in total laparoscopic hysterectomy: a retrospective study

被引:16
作者
Usta, Taner A. [1 ]
Karacan, Tolga [2 ]
Naki, M. Murat [3 ]
Calik, Aysel [1 ]
Turkgeldi, Lale [2 ]
Kasimogullari, Volkan [1 ]
机构
[1] Bagcilar Educ & Res Hosp, Dept Obstet & Gynecol, TR-34200 Istanbul, Turkey
[2] Kanuni Educ & Res Hosp, Dept Obstet & Gynecol, Istanbul, Turkey
[3] Liv Hosp, Dept Obstet & Gynecol, Istanbul, Turkey
关键词
Laparoscopy; 3-Dimensional laparoscopic vision system; 2 Dimensional laparoscopic vision system; Laparoscopic hysterectomy; IMPROVES SURGICAL PERFORMANCE;
D O I
10.1007/s00404-014-3253-1
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
We compare the results of total laparoscopic hysterectomy (TLH) operations conducted using standard 2-D and 3-D high definition laparoscopic vision systems and discuss the findings with regard to the recent literature. Data from 147 patients who underwent TLH operations with 2-D or 3-D high definition laparoscopic vision systems in Department of Obstetrics and Gynecology, Bagcilar Training and Research Hospital, during 2 year period between December 2010 and December 2012, were reviewed retrospectively. TLH operations were divided into two groups as those performed using 2-D, and those performed using 3-D high definition laparoscopic vision systems. A statistically significant difference was found between the two groups in the operation times (p = 0.037 < 0.05). The mean operation time of the 2-D laparoscopy group (134.2 +/- A 61.8 min) was higher than the 3-D laparoscopy group (116.8 +/- A 38.5 min). No statistically significant difference was found between the 2-D and 3-D groups with respect to major, minor and total complication rates (p = 0.641 > 0.05). The operation time among obese patients was significantly shorter in those in the 3-D laparoscopy group than those in the 2-D group (p = 0.041 < 0.05). Recent literature indicates that 3-D laparoscopy vision system needs to be utilized more often and a higher number of ex vivo and in vivo studies have to be conducted. Furthermore, we believe that the prevalent problems encountered during laparoscopy can be overcome by the development of real-time vision devices and the appropriate training of the laparoscopists. 3-D high definition laparoscopic vision system will help to improve surgical performance and outcome of patients undergoing gynecological minimal invasive surgery.
引用
收藏
页码:705 / 709
页数:5
相关论文
共 22 条
  • [1] [Anonymous], 2009, 444 ACOG COMM, V114, P1156
  • [2] Comparison of two-dimensional and three-dimensional suturing: Is there a difference in a robotic surgery setting?
    Badani, KK
    Bhandari, A
    Tewari, A
    Menon, M
    [J]. JOURNAL OF ENDOUROLOGY, 2005, 19 (10) : 1212 - 1215
  • [3] Becker H, 1993, Endosc Surg Allied Technol, V1, P40
  • [4] Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System
    Byrn, John C.
    Schluender, Stefanie
    Divino, Celia M.
    Conrad, John
    Gurland, Brooke
    Shlasko, Edward
    Szold, Amir
    [J]. AMERICAN JOURNAL OF SURGERY, 2007, 193 (04) : 519 - 522
  • [5] RELATIONSHIP BETWEEN THE APPARENT VERTICAL AND THE VERTICAL HOROPTER
    COGAN, AI
    [J]. VISION RESEARCH, 1979, 19 (06) : 655 - 665
  • [6] Coren S, 1989, SENSATION PERCEPTION, P274
  • [7] A comparison of single- and multiple-stage approaches to teaching laparoscopic suturing
    Dubrowski, Adam
    Park, Jason
    Moulton, Carol-anne
    Larmer, James
    MacRae, Helen
    [J]. AMERICAN JOURNAL OF SURGERY, 2007, 193 (02) : 269 - 273
  • [8] The eVALuate study: two parallel randomised trials, one comparing laparoscopic with abdominal hysterectomy, the other comparing laparoscopic with vaginal hysterectomy
    Garry, R
    Fountain, J
    Mason, S
    Napp, V
    Brown, J
    Hawe, J
    Clayton, R
    Abbott, J
    Phillips, G
    Whittaker, M
    Lilford, R
    Bridgman, S
    [J]. BRITISH MEDICAL JOURNAL, 2004, 328 (7432): : 129 - 133
  • [9] Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy
    Hanna, GB
    Shimi, SM
    Cuschieri, A
    [J]. LANCET, 1998, 351 (9098) : 248 - 251
  • [10] Three-Dimensional Laparoscopic Imaging Improves Surgical Performance on Standardized Ex-Vivo Laparoscopic Tasks
    Honeck, Patrick
    Wendt-Nordahl, Gunnar
    Rassweiler, Jens
    Knoll, Thomas
    [J]. JOURNAL OF ENDOUROLOGY, 2012, 26 (08) : 1085 - 1088