Non-contact laser/EMAT measurement systems for ultrasound B-scan imaging

被引:0
|
作者
Dewhurst, RJ [1 ]
Murray, PR [1 ]
机构
[1] UMIST, Dept Instrumentat & Analyt Sci, Manchester M60 1QD, Lancs, England
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
For non-contact non-destructive evaluation (NDE), a laser/EMAT system is an alternative to a more expensive all optical laser-ultrasound system. Several design options of the electromagnetic acoustic transducer (EMAT) are available, permitting inspection of electrically conducting materials. In this paper, we describe a system capable of monitoring variation in either sample thickness or defects, with time-of-flight diffraction arising from mode-converted ultrasonic waves, In a B-scan imaging configuration, quantitative time-of-flight analysis of laser-generated acoustic waves is shown to be an effective method for measurement. Various images will be presented together with an interpretation of their features. For these images, transient laser pulses with typical energies of similar to18mJ have been delivered to the material surface via an optical fiber and focused to a line source by a cylindrical lens. Acoustic waves arising from this excitation propagated through the sample to be reflected from the far surface. Waves returning to the surface, including L-S and S-L mode-converted waves, were detected using an EMAT sensitive to in-plane motion. B-scans have been generated as the sensor head moved along the material's surface, forming a 2-D intensity profile that made changes in plate thickness easy to visualize. Both L-S and S-L mode-converted waves provided a method of simultaneously monitoring two different points on the far surface enabling any changes in the material thickness to be clearly identified.
引用
收藏
页码:348 / 355
页数:8
相关论文
共 50 条
  • [1] CONTACT B-SCAN ULTRASOUND OF THE BREAST
    LALANI, Z
    JACKSON, FI
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 : 235 - 242
  • [2] ULTRASOUND HOLOGRAPHIC B-SCAN IMAGING
    YLITALO, J
    ALASAARELA, E
    KOIVUKANGAS, J
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1989, 36 (03) : 376 - 383
  • [3] Non-Contact Laser Ultrasound Concept for Biomedical Imaging
    Haupt, Robert
    Wynn, Charles
    Fincke, Jonathan
    Zhang, Xiang
    Anthony, Brian
    Samir, Anthony
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [4] Superresolution imaging of scatterers in ultrasound B-scan imaging
    Parker, Kevin J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 131 (06): : 4680 - 4689
  • [5] Non-contact measurement of elastic modulus by using laser ultrasound
    Kim, Jongbeom
    Jhang, Kyoung-Young
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (05) : 905 - 909
  • [6] Non-contact measurement of elastic modulus by using laser ultrasound
    Jongbeom Kim
    Kyoung-Young Jhang
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 905 - 909
  • [7] DIRECT-CONTACT B-SCAN SONOMAMMOGRAPHY (BREAST ULTRASOUND)
    GUYER, PB
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (702): : 634 - 635
  • [8] B-scan ultrasound imaging measurement of suspended sediment concentration and its vertical distribution
    Zou, Xian-jian
    Ma, Zhi-min
    Zhao, Xiao-hong
    Hu, Xiang-yang
    Tao, Wei-liang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (11)
  • [9] CONTACT B-SCAN ULTRASONOGRAPHY
    BRONSON, NR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1974, 77 (02) : 181 - 191
  • [10] ULTRASOUND B-SCAN IN SPLENOMEGALY
    ROSENMAYR, F
    WIENER KLINISCHE WOCHENSCHRIFT, 1975, 87 (18) : 606 - 608