Gold nanoparticles plated porous silicon nanopowder for nonenzymatic voltammetric detection of hydrogen peroxide

被引:20
作者
Rashed, Md. A. [1 ,7 ]
Harraz, Farid A. [1 ,4 ]
Faisal, M. [1 ,2 ]
El-Toni, Ahmed Mohamed [3 ]
Alsaiari, Mabkhoot [1 ,5 ]
Al-Assiri, M. S. [1 ,6 ]
机构
[1] Najran Univ, Adv Mat & Nanores Ctr, Promising Ctr Sensors & Elect Devices PCSED, POB 1988, Najran 11001, Saudi Arabia
[2] Najran Univ, Fac Sci & Arts, Dept Chem, Najran, Saudi Arabia
[3] King Saud Univ, King Abdullah Inst Nanotechnol, Riyadh 11451, Saudi Arabia
[4] Cent Met Res & Dev Inst CMRDI, Nanomat & Nanotechnol Dept, PO 87, Cairo 11421, Egypt
[5] Najran Univ, Fac Sci & Arts Sharurah, Dept Chem, Najran, Saudi Arabia
[6] Najran Univ, Fac Sci & Arts, Dept Phys, Najran, Saudi Arabia
[7] Mawlana Bhashani Sci & Technol Univ, Fac Sci, Dept Chem, Santosh 1902, Tangail, Bangladesh
关键词
AuNPs; PSi; H2O2; sensor; Linear sweep voltammetry; Square wave voltammetry; Sensitivity; GLASSY-CARBON ELECTRODE; REDUCED GRAPHENE OXIDE; ORGANIC VAPOR SENSOR; ELECTROCHEMICAL DETECTION; SILVER NANOPARTICLES; MESOPOROUS SILICON; OPTICAL BIOSENSOR; QUANTUM DOTS; N-TYPE; H2O2;
D O I
10.1016/j.ab.2020.114065
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A voltammetric approach was developed for the selective and sensitive determination of hydrogen peroxide using Au plated porous silicon (PSi) nanopowder modified glassy carbon electrode (GCE). The AuNPs-PSi hybrid structure was synthesized via stain etching procedure followed by an immersion plating method to deposit AuNPs onto PSi via a simple galvanic displacement reaction with no external reducing agent to convert Au3+ to Au-0. The as-fabricated AuNPs-PSi catalyst was successfully characterized by XRD, Raman, FTIR, XPS, SEM, TEM and EDS techniques. Well crystalline nature of the as-fabricated hybrid structure with AuNPs size ranging from 5 to 40 nm was observed. The specific surface area and total pore volume for both PSi and AuNPs plated PSi were evaluated using N-2 adsorption isotherm technique. Cyclic voltammetry and electrochemical impedance spectroscopy techniques were applied to investigate the catalytic efficiency of AuNPs-PSi modified electrode compared to pure PSi/GCE and unmodified GCE. The sensing performance of the active material modified GCE was thoroughly examined with linear sweep voltammetry (LSV) and square wave voltammetry (SWV) techniques. The AuNPs-PSi/GCE exhibited a remarkable linear dynamic range between 2.0 and 13.81 mM (for LSV) and 0.5-6.91 mM for (SWV) with high sensitivity and low detection limit of 10.65 mu AmM(-1)cm(2) and 14.84 mu M for LSV, whereas 10.41 mu AmM(-1)cm(2) and 15.16 mu M using SWV techniques, respectively. The fabricated sensor electrode showed excellent anti-interfering ability in the presence of several common biomolecules as well as demonstrated good operational stability and reproducibility with low relative standard deviation. Moreover, the modified electrode showed acceptable recovery of H2O2 in a real sample analysis. Thus, the developed AuNPs-PSi hybrid nanomaterial represents an excellent electrocatalyst for the efficient detection and quantification of H2O2 by the electrochemical approach.
引用
收藏
页数:12
相关论文
共 50 条
[41]   Graphene oxide-gold nanozyme for highly sensitive electrochemical detection of hydrogen peroxide [J].
Jin, Ga Hyun ;
Ko, Euna ;
Kim, Min Ki ;
Tran, Van-Khue ;
Son, Seong Eun ;
Geng, Yanfang ;
Hur, Won ;
Seong, Gi Hun .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 274 :201-209
[42]   A novel nonenzymatic hydrogen peroxide sensor based on multi-wall carbon nanotube/silver nanoparticle nanohybrids modified gold electrode [J].
Zhao, Wei ;
Wang, Huicai ;
Qin, Xia ;
Wang, Xinsheng ;
Zhao, Zixia ;
Miao, Zhiying ;
Chen, Lili ;
Shan, Miaomiao ;
Fang, Yuxin ;
Chen, Qiang .
TALANTA, 2009, 80 (02) :1029-1033
[43]   Ultrasensitive Nonenzymatic Real-Time Hydrogen Peroxide Monitoring Using Gold Nanoparticle-Decorated Titanium Dioxide Nanotube Electrodes [J].
Kader, Md. Ashraful ;
Azmi, Nina Suhaity ;
Kafi, A. K. M. ;
Hossain, Md. Sanower ;
Jose, Rajan ;
Goh, Khang Wen .
BIOSENSORS-BASEL, 2023, 13 (07)
[44]   Facile Fabrication of Au Nanoparticles Immobilized on Polyaniline Nanofibers: High Sensitive Nonenzymatic Hydrogen Peroxide Sensor [J].
Ma, PiMing ;
Zhu, Han ;
Wei, JunKan ;
Zhang, Ming .
NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2015, 7 (02) :127-133
[45]   Sensitive determination of hydrogen peroxide based on a novel nonenzymatic electrochemical sensor: silver nanoparticles decorated on nanodiamonds [J].
Biuck Habibi ;
Mojtaba Jahanbakhshi .
Journal of the Iranian Chemical Society, 2015, 12 :1431-1438
[46]   Sensitive determination of hydrogen peroxide based on a novel nonenzymatic electrochemical sensor: silver nanoparticles decorated on nanodiamonds [J].
Habibi, Biuck ;
Jahanbakhshi, Mojtaba .
JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2015, 12 (08) :1431-1438
[47]   Gold nanoclusters as switch-off fluorescent probe for detection of uric acid based on the inner filter effect of hydrogen peroxide-mediated enlargement of gold nanoparticles [J].
Liu, Yanyan ;
Li, Hongchang ;
Guo, Bin ;
Wei, Lijuan ;
Chen, Bo ;
Zhang, Youyu .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :734-740
[48]   Covalent attachment of thionine onto gold electrode modified with cadmium sulfide nanoparticles: Improvement of electrocatalytic and photelectrocatalytic reduction of hydrogen peroxide [J].
Salimi, Abdollah ;
Rahmatpanah, Rojzin ;
Hallaj, Rahman ;
Roushani, Mahmoud .
ELECTROCHIMICA ACTA, 2013, 95 :60-70
[49]   Amperometric sensing of hydrogen peroxide via an ITO electrode modified with gold nanoparticles electrodeposited on a CoMn-layered double hydroxide [J].
Xu, Liang ;
Lian, Meiling ;
Chen, Xu ;
Lu, Yanluo ;
Yang, Wensheng .
MICROCHIMICA ACTA, 2017, 184 (10) :3989-3996
[50]   Immobilizing Gold Nanoparticles in Mesoporous Silica Covered Reduced Graphene Oxide: A Hybrid Material for Cancer Cell Detection through Hydrogen Peroxide Sensing [J].
Maji, Swarup Kumar ;
Sreejith, Sivaramapanicker ;
Mandal, Amal Kumar ;
Ma, Xing ;
Zhao, Yanli .
ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (16) :13648-13656