Optical coherence tomography of coronary arteries - a novel intravascular imaging modality

被引:2
|
作者
Mrevlje, B. [1 ]
Legutko, J. [2 ]
Jakala, J. [2 ]
Noc, M. [3 ]
Dudek, D. [2 ]
Birkemeyer, R. [4 ]
Aboukoura, M. [1 ]
Nienaber, C. [1 ]
机构
[1] Univ Med Rostock, Zentrum Innere Med, Med Klin 1, Abt Kardiol, D-18057 Rostock, Germany
[2] Jagiellonian Univ Klin Krakau, Inst Kardiol, Krakow, Poland
[3] Univ Klin Ljubljana, Abt Internist Intens Med, Ljubljana, Slovenia
[4] Herzklin Ulm, Ulm, Germany
关键词
optical coherence tomography; atherosclerotic plaque; acute coronary syndrome; wall composition; in vivo-microscopy; ELEVATION MYOCARDIAL-INFARCTION; ULTRASOUND ASSESSMENT; CLINICAL-APPLICATIONS; LESION COVERAGE; ATHEROSCLEROSIS; INTERVENTION; TERMINOLOGY; ACQUISITION; METHODOLOGY; DOCUMENT;
D O I
10.1055/s-0034-1387280
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Optical coherence tomography (OCT) is the latest intravascular imaging modality for the investigation of coronary arteries. It can be used in patients with stable coronary artery disease as well as in patients with acute coronary syndrome. Its almost microscope-like resolution of 10-20 μm (10-times greater than intravascular ultrasound) gives us the most detailed insight into the coronary artery wall in vivo so far. Optical coherence tomography can be used for accurate qualitative and quantitative assessment of stenoses in stable coronary artery disease and accurate guidance of percutaneous coronary interventions as well as accurate postprocedural control. In patients with acute coronary syndrome it can be used for the detection of culprit of the culprit lesion (vulnerable plaque) which allows the operator to cover not only angiographically tightest stenosis (angiographic culprit lesion, caused in most cases by thrombus only) but most importantly the vulnerable plaque, which led to the acute event, as well. Furthermore, optical coherence tomography allows accurate assessment of thrombotic burden, stent apposition/malapposition, edge dissections and tissue prolaps or thrombus protrusions throught stent struts, etc © Georg Thieme Verlag KG Stuttgart New York.
引用
收藏
页码:1941 / 1946
页数:6
相关论文
共 50 条
  • [1] Intravascular ultrasound and optical coherence tomography imaging of coronary atherosclerosis
    Costopoulos, Charis
    Brown, Adam J.
    Teng, Zhongzhao
    Hoole, Stephen P.
    West, Nick E. J.
    Samady, Habib
    Bennett, Martin R.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01) : 189 - 200
  • [2] Automatic fibroatheroma identification in intravascular optical coherence tomography volumes
    Yan, Qifeng
    Xu, Mengdi
    Wong, Damon Wing Kee
    Taruya, Akira
    Tanaka, Atsushi
    Liu, Jiang
    Wong, Philip
    Cheng, Jun
    JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2019, 14 (11) : 15477 - 15483
  • [3] Optical Coherence Tomography of Coronary Arteries
    Roland, Robert
    Veselka, Josef
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2021, 30 (01) : 29 - 39
  • [4] INTRAVASCULAR IMAGING OF ATHEROSCLEROTIC PLAQUES IN PATIENTS WITH CARDIORENAL SYNDROME: POSSIBILITIES OF OPTICAL COHERENCE TOMOGRAPHY
    Sozykin, A. V.
    Shevchenko, O. P.
    Naumov, Ya. A.
    Strokov, A. G.
    Vasilieva, V. P.
    Shevchenko, A. O.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2019, 21 (04): : 121 - 128
  • [5] Histogram-based standardization of intravascular optical coherence tomography images acquired from different imaging systems
    Liu, Shengnan
    Dzyubachyk, Oleh
    Eggermont, Jeroen
    Nakatani, Shimpei
    Lelieveldt, Boudewijn P. F.
    Dijkstra, Jouke
    MEDICAL PHYSICS, 2018, 45 (09) : 4158 - 4170
  • [6] Prospective Evaluation of Optical Coherence Tomography in Lower Limb Arteries Compared with Intravascular Ultrasound
    Eberhardt, Karla Maria
    Treitl, Marcus
    Boesenecker, Katrin
    Maxien, Daniel
    Reiser, Maximilian
    Rieger, Johannes
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (10) : 1499 - 1508
  • [7] Intravascular ultrasound and optical coherence tomography imaging of coronary atherosclerosis
    Charis Costopoulos
    Adam J. Brown
    Zhongzhao Teng
    Stephen P. Hoole
    Nick E. J. West
    Habib Samady
    Martin R. Bennett
    The International Journal of Cardiovascular Imaging, 2016, 32 : 189 - 200
  • [8] Intravascular imaging in acute coronary syndrome: Intravascular ultrasound and optical coherence tomography
    Mrevlje B.
    Legutko J.
    Tillwich F.
    Jakala J.
    Dudek D.
    Noč M.
    Rzeszutko L.
    Kleczynski P.
    Birkemeyer R.
    Aboukoura M.
    Nienaber C.A.
    Der Kardiologe, 2015, 9 (1): : 47 - 53
  • [9] Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries
    Slottow, Tina L. Pinto
    Pakala, Rajbabu
    Okabe, Teruo
    Hellinga, David
    Lovec, Rachel J.
    Tio, Fermin O.
    Bui, Anh B.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2008, 9 (04) : 248 - 254
  • [10] Hybrid intravascular ultrasound and optical coherence tomography catheter for imaging of coronary atherosclerosis
    Li, Brian H.
    Leung, Annie S. O.
    Soong, Alan
    Munding, Chelsea E.
    Lee, Hyunggyun
    Thind, Amandeep S.
    Munce, Nigel R.
    Wright, Graham A.
    Rowsell, Corwyn H.
    Yang, Victor X. D.
    Strauss, Bradley H.
    Foster, F. Stuart
    Courtney, Brian K.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 494 - 507