Validation of an MPC Polymer Coating to Attenuate Surface-Induced Crosstalk between the Complement and Coagulation Systems in Whole Blood in In Vitro and In Vivo Models

被引:31
作者
Asif, Sana [1 ]
Asawa, Kenta [2 ]
Inoue, Yuuki [2 ]
Ishihara, Kazuhiko [2 ]
Lindell, Bjorn [1 ,3 ]
Holmgren, Robin [1 ]
Nilsson, Bo [1 ]
Ryden, Anneli [4 ]
Jensen-Waern, Marianne [4 ]
Teramura, Yuji [1 ,2 ]
Ekdahl, Kristina N. [1 ,5 ]
机构
[1] Uppsala Univ, Dept Immunol Genet & Pathol, Dag Hammarskjolds Vag 20, SE-75185 Uppsala, Sweden
[2] Univ Tokyo, Dept Bioengn, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[3] Uppsala Univ, Dept Surg Sci Plast & Maxillofacial Surg, Dag Hammarskjolds Vag 20, SE-75185 Uppsala, Sweden
[4] Swedish Univ Agr Sci, Fac Vet Med & Anim Sci, Dept Clin Sci, Almas Alle 8, S-75007 Uppsala, Sweden
[5] Linnaeus Univ, Linnaeus Ctr Biomat Chem, SE-39182 Kalmar, Sweden
基金
瑞典研究理事会; 日本学术振兴会;
关键词
blood compatibility; blood model systems; coagulation system; complement system; heparin coat; MPC polymer coat; PROTEIN ADSORPTION; PHOSPHOLIPID POLYMERS; HUMAN-PLASMA; ACTIVATION; COMPATIBILITY; BIOMATERIAL; INTERFACE; COPOLYMER;
D O I
10.1002/mabi.201800485
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Artificial surfaces that come into contact with blood induce an immediate activation of the cascade systems of the blood, leading to a thrombotic and/or inflammatory response that can eventually cause damage to the biomaterial or the patient, or to both. Heparin coating has been used to improve hemocompatibility, and another approach is 2-methacryloyloxyethyl phosphorylcholine (MPC)-based polymer coatings. Here, the aim is to evaluate the hemocompatibility of MPC polymer coating by studying the interactions with coagulation and complement systems using human blood in vitro model and pig in vivo model. The stability of the coatings is investigated in vitro and MPC polymer-coated catheters are tested in vivo by insertion into the external jugular vein of pigs to monitor the catheters' antithrombotic properties. There is no significant activation of platelets or of the coagulation and complement systems in the MPC polymer-coated one, which was superior in hemocompatibility to non-coated matrix surfaces. The protective effect of the MPC polymer coat does not decline after incubation in human plasma for up to 2 weeks. With MPC polymer-coated catheters, it is possible to easily draw blood from pig for 4 days in contrast to the case for non-coated catheters, in which substantial clotting is seen.
引用
收藏
页数:12
相关论文
共 37 条
  • [1] Binding of a model regulator of complement activation (RCA) to a biomaterial surface: surface-bound factor H inhibits complement activation
    Andersson, J
    Larsson, R
    Richter, R
    Ekdahl, KN
    Nilsson, B
    [J]. BIOMATERIALS, 2001, 22 (17) : 2435 - 2443
  • [2] Heparin coatings for improving blood compatibility of medical devices
    Biran, Roy
    Pond, Daniel
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2017, 112 : 12 - 23
  • [3] Blezer R, 1997, J BIOMED MATER RES, V37, P108, DOI 10.1002/(SICI)1097-4636(199710)37:1<108::AID-JBM13>3.0.CO
  • [4] 2-C
  • [5] Brunski J.B., 2013, BIOMATER SCI-UK, Vthird, P111
  • [6] Heparin coating of the stent graft - effects on platelets, coagulation and complement activation
    Christensen, K
    Larsson, R
    Emanuelsson, H
    Elgue, G
    Larsson, A
    [J]. BIOMATERIALS, 2001, 22 (04) : 349 - 355
  • [7] GENERATION OF IC3 AT THE INTERFACE BETWEEN BLOOD AND GAS
    EKDAHL, KN
    NILSSON, B
    PEKNA, M
    NILSSON, UR
    [J]. SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1992, 35 (01) : 85 - 91
  • [8] Cardiovascular disease in haemodialysis: role of the intravascular innate immune system
    Ekdahl, Kristina N.
    Soveri, Inga
    Hilborn, Jons
    Fellstrom, Bengt
    Nilsson, Bo
    [J]. NATURE REVIEWS NEPHROLOGY, 2017, 13 (05) : 285 - 296
  • [9] Thromboinflammation in Therapeutic Medicine
    Ekdahl, Kristina N.
    Teramura, Yuji
    Asif, Sana
    Jonsson, Nina
    Magnusson, Peetra U.
    Nilsson, Bo
    [J]. IMMUNE RESPONSES TO BIOSURFACES: MECHANISMS AND THERAPEUTIC INTERVENTIONS, 2015, 865 : 3 - 17
  • [10] ANALYSIS OF UROKINASE IMMOBILIZATION ON THE POLYTETRAFLUOROETHYLENE VASCULAR PROSTHESIS
    FORSTER, RI
    BERNATH, F
    [J]. AMERICAN JOURNAL OF SURGERY, 1988, 156 (02) : 130 - 132