Evolution of in vivo assessed retention forces in one-piece mini dental implant-retained mandibular overdentures: 5-Year follow-up of a prospective clinical trial

被引:7
作者
Abou-Ayash, Samir [1 ]
Enkling, Norbert [2 ,3 ]
Srinivasan, Murali [4 ]
Haueter, Marius [5 ]
Worni, Andreas
Schimmel, Martin [5 ,6 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dent DIRecD, Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[3] Univ Bonn, Dept Prosthodont, Bonn, Germany
[4] Univ Zurich, Ctr Dent Med, Clin Gen Special Care & Geriatr Dent, Zurich, Switzerland
[5] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Div Gerodontol, Bern, Switzerland
[6] Univ Geneva, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
关键词
NARROW-DIAMETER IMPLANTS; TOOTH LOSS; ATTACHMENTS; ASSOCIATION; EDENTULISM; SURVIVAL; SUCCESS; LIFE; CARE;
D O I
10.1111/cid.12816
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background The evolution of retention forces in one-piece mini dental implants (MDIs) retaining implant overdentures (IODs) is of major importance, as the male parts cannot be exchanged, due to the implant design. Purpose To report the evolution of retention forces of one-piece MDIs, retaining mandibular IODs with ball/ O-ring attachments during 5 years assessed in vivo. Materials and Methods Four MDIs were installed in the interforaminal region and immediately loaded using the existing mandibular complete denture. Directly post-op, at the 1-year and the 5-year follow-up, the retention forces were assessed with a validated strain gauge at each implant site separately. Results At the male part, changes could only be observed at implant site 34: During the first year, there was a statistically significant increase, whereas the retention forces were decreased at the 5-year follow-up. At the female part, retention forces decreased significantly over time. Baseline values could be reestablished by exchanging the O-rings. The changes of the retention forces were more obvious in the posterior, compared to the anterior implants. Conclusions Retention forces at the female part decrease significantly over time, when retaining mandibular IODs by MDIs with ball/ O-ring attachments. Baseline values can be reestablished by exchanging the O-rings. At the male part, changes of retention forces depend on the implant location.
引用
收藏
页码:968 / 976
页数:9
相关论文
共 42 条
  • [1] Al-Nawas B, 2014, EUR J ORAL IMPLANTOL, V7, pS219
  • [2] Measuring patient satisfaction with mandibular prostheses
    Awad, MA
    Feine, JS
    [J]. COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1998, 26 (06) : 400 - 405
  • [3] Retention force of plastic clips on implant bars: a randomized controlled trial
    Bayer, Stefan
    Komor, Nathalie
    Kramer, Annina
    Albrecht, Dominic
    Mericske-Stern, Regina
    Enkling, Norbert
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (12) : 1377 - 1384
  • [4] Comparative study of four retentive anchor systems for implant supported overdentures - retention force changes
    Bayer, Stefan
    Steinheuser, Daniela
    Gruener, Manfred
    Keilig, Ludger
    Enkling, Norbert
    Stark, Helmut
    Mues, Sebastian
    [J]. GERODONTOLOGY, 2009, 26 (04) : 268 - 272
  • [5] Resistance to Wear of Four Matrices with Ball Attachments for Implant Overdentures: A Fatigue Study
    Branchi, Roberto
    Vangi, Dario
    Virga, Antonio
    Guertin, Genevieve
    Fazi, Giovanni
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (08): : 31 - 36
  • [6] Mandibular Overdentures Retained by Two Mini-Implants: A Seven-Year Retention and Satisfaction Study
    Catalan, Alfonso
    Martinez, Alejandra
    Marchesani, Francisco
    Gonzalez, Urcesino
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (05): : 364 - 370
  • [7] FREEDOM OF ROTATION OF SELECTED OVERDENTURE ATTACHMENTS: AN IN VITRO STUDY
    Chen, I-Chieh
    Brudvik, James S.
    Mancl, Lloyd A.
    Rubenstein, Jeffrey E.
    Chitswe, Kinsey
    Raigrodski, Ariel J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (02) : 78 - 86
  • [8] Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations
    Choi, Jae-Won
    Bae, Ji-Hyeon
    Jeong, Chang-Mo
    Huh, Jung-Bo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05) : 628 - 635
  • [9] Mini vs. Standard Implants for Mandibular Overdentures: A Randomized Trial
    de Souza, R. F.
    Ribeiro, A. B.
    Della Vecchia, M. P.
    Costa, L.
    Cunha, T. R.
    Reis, A. C.
    Albuquerque, R. F., Jr.
    [J]. JOURNAL OF DENTAL RESEARCH, 2015, 94 (10) : 1376 - 1384
  • [10] The clinical and radiographic outcome of immediately loaded mini implants supporting a mandibular overdenture. A 3-year prospective study
    Elsyad, M. A.
    Gebreel, A. A.
    Fouad, M. M.
    Elshoukouki, A. H.
    [J]. JOURNAL OF ORAL REHABILITATION, 2011, 38 (11) : 827 - 834